Simultaneous maximization of cell permeabilization and viability in single-cell electroporation using an electrolyte-filled capillary

被引:11
作者
Agarwal, Aparna
Zudans, Imants
Orwar, Owe
Weber, Stephen G. [1 ]
机构
[1] Univ Pittsburgh, Dept Chem, Pittsburgh, PA 15260 USA
[2] Chalmers Univ Technol, Dept Phys Chem, SE-41296 Gothenburg, Sweden
关键词
D O I
10.1021/ac061270o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A549 cells were briefly exposed to Thioglo-1, which converts thiols to fluorescent adducts. The fluorescent cells were exposed to short (50-300 ms) electric field pulses (500 V across a 15 cm capillary) created at the tip of an electrolyte-filled capillary. Fluorescence microscopy revealed varying degrees of cell permeabilization depending on the conditions. Longer pulses and a shorter cell-capillary tip distance led to a greater decrease in the cell's fluorescence. Live/dead (calcein AM and propidium iodide) testing revealed that a certain fraction of cells died. Longer pulses and shorter cell-capillary tip distances were more deadly. An optimum condition exists at a cell-capillary tip distance of 3.5-4.5 mu m and a pulse duration of 120-150 ms. At these conditions, > 90% of the cells are permeabilized and 80-90% survive.
引用
收藏
页码:161 / 167
页数:7
相关论文
共 54 条
  • [11] Micro pulsed radio-frequency electroporation chips
    He, HQ
    Chang, DC
    Lee, YK
    [J]. BIOELECTROCHEMISTRY, 2006, 68 (01) : 89 - 97
  • [12] TIME COURSES OF CELL ELECTROPORATION AS REVEALED BY SUBMICROSECOND IMAGING OF TRANSMEMBRANE POTENTIAL
    HIBINO, M
    ITOH, H
    KINOSITA, K
    [J]. BIOPHYSICAL JOURNAL, 1993, 64 (06) : 1789 - 1800
  • [13] Flow-through micro-electroporation chip for high efficiency single-cell genetic manipulation
    Huang, Y
    Rubinsky, B
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2003, 104 (03) : 205 - 212
  • [14] Microfabricated electroporation chip for single cell membrane permeabilization
    Huang, Y
    Rubinsky, B
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2001, 89 (03) : 242 - 249
  • [15] Kagan VE, 2001, CANCER RES, V61, P7777
  • [16] A single cell electroporation chip
    Khine, M
    Lau, A
    Ionescu-Zanetti, C
    Seo, J
    Lee, LP
    [J]. LAB ON A CHIP, 2005, 5 (01) : 38 - 43
  • [17] Cell membrane electropermeabilization by symmetrical bipolar rectangular pulses - Part II. Reduced electrolytic contamination
    Kotnik, T
    Miklavcic, D
    Mir, LM
    [J]. BIOELECTROCHEMISTRY, 2001, 54 (01): : 91 - 95
  • [18] Role of pulse shape in cell membrane electropermeabilization
    Kotnik, T
    Pucihar, G
    Rebersek, M
    Miklavcic, D
    Mir, LM
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2003, 1614 (02): : 193 - 200
  • [19] Cell membrane electropermeabilization by symmetrical bipolar rectangular pulses - Part I. Increased efficiency of permeabilization
    Kotnik, T
    Mir, LM
    Flisar, K
    Puc, M
    Miklavcic, D
    [J]. BIOELECTROCHEMISTRY, 2001, 54 (01): : 83 - 90
  • [20] Direct monitoring of the field strength during electropulsation
    Loste, F
    Eynard, N
    Teissié, J
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 47 (01): : 119 - 127