Diagnostic accuracy of glycated hemoglobin for gestational diabetes mellitus: a systematic review and meta-analysis

被引:32
作者
Renz, Paula B. [3 ]
Chume, Fernando C. [3 ,4 ]
Timm, Joao R. T. [3 ]
Pimentel, Ana L. [3 ]
Camargo, Joiza L. [1 ,2 ,3 ]
机构
[1] Hosp Clin Porto Alegre, Expt Res Ctr, Rua Ramiro Barcelos 2350,Predio 12 CPE,4 Andar, BR-90035903 Porto Alegre, RS, Brazil
[2] Hosp Clin Porto Alegre, Endocrinol Div, Rua Ramiro Barcelos 2350,Predio 12 CPE,4 Andar, BR-90035903 Porto Alegre, RS, Brazil
[3] Univ Fed Rio Grande do Sul, Grad Program Endocrinol, Porto Alegre, RS, Brazil
[4] Univ Zambeze, Beira, Mozambique
关键词
diagnosis; gestational diabetes; HbA(1c); meta-analysis; GLYCOSYLATED HEMOGLOBIN; EARLY-PREGNANCY; HBA(1C); HYPERGLYCEMIA; TESTS; WOMEN; HBA1C; A1C; ASSOCIATION; QUALITY;
D O I
10.1515/cclm-2018-1191
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: We conducted a systematic review and meta-analysis to establish the overall accuracy of glycated hemoglobin (HbA(1c)) in the diagnosis of gestational diabetes mellitus (GDM) diagnosis. Methods: We searched MEDLINE, EMBASE, SCOPUS and ClinicalTrials.gov up to October 2018, using keywords related to GDM, HbA(1c) and diagnosis. Studies were included that were carried out with pregnant women without previous diabetes that assessed the performance of HbA(1c) (index test) compared to the 75 g oral glucose tolerance test (OGTT) (reference test) for the diagnosis of GDM, that measured HbA(1c) by standardized methods and presented data necessary for drawing 2 x 2 tables. Results: This meta-analysis included eight studies, totaling 6406 pregnant women, of those 1044 had GDM. The diagnostic accuracy of HbA(1c) was reported at different thresholds ranging from 5.4% (36 mmol/mol) to 6.0% (42 mmol/mol), and the area under the curve (AUC) was 0.825 (95% confidence interval [CI] 0.751-0.899), indicating a good level of overall accuracy. The pooled sensitivities and specificities were 50.3% (95% CI 24.8%-75.7%) and 83.7% (67.5%-92.7%); 24.7% (10.3%-48.5%) and 95.5% (85.7%-98.7%); 10.8% (5.7%-19.41%) and 98.7% 96.2%-99.5%); 12.9% (5.5%-27.5%) and 98.7% (97.6%-99.3%), for the cut-offs of 5.4% (36 mmol/mol), 5.7% (39 mmol/mol), 5.8% (40 mmol/mol) and 6.0% (42 mmol/mol), respectively. Conclusions: We observed a high heterogeneity among the studies. The effect of ethnicities, different criteria for OGTT interpretation and the individual performance of HbA(1c) methods may have contributed to this heterogeneity. The HbA(1c) test presents high specificity but low sensitivity regardless of the threshold used to diagnose GDM. These findings point to the usefulness of HbA(1c) as a rule-in test. HbA(1c) should be used in association with other standard diagnostic tests for GDM diagnosis.
引用
收藏
页码:1435 / 1449
页数:15
相关论文
共 52 条
  • [1] Gestational diabetes: a reappraisal of HBA1c as a screening test
    Agarwal, MM
    Dhatt, GS
    Punnose, J
    Koster, G
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2005, 84 (12) : 1159 - 1163
  • [2] Diagnostic criteria and classification of hyperglycaemia first detected in pregnancy: A World Health Organization Guideline
    Agarwal, Mukesh M.
    Boulvain, Michel
    Coetzee, Edward
    Colagiuri, Stephen
    Falavigna, Maicon
    Hod, Moshe
    Meltzer, Sara
    Metzger, Boyd
    Omori, Yasue
    Rasa, Ingvars
    Schmidt, Maria Ines
    Seshiah, Veerasamy
    Simmons, David
    Sobngwi, Eugene
    Torloni, Maria Regina
    Yang, Huixia
    Balaji, V.
    Mendis, Shanthi P. B.
    Roglic, Gojka
    Merialdi, Mario
    Betran, Ana Pilar
    Jenum, Anne Karen
    Lao, Terence
    Lopez Stewart, Gloria
    Mikhailov, Anton
    Moses, Robert
    Samad, Noorjahan
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2014, 103 (03) : 341 - 363
  • [3] Understanding diagnostic tests 2: likelihood ratios, pre- and post-test probabilities and their use in clinical practice
    Akobeng, Anthony K.
    [J]. ACTA PAEDIATRICA, 2007, 96 (04) : 487 - 491
  • [4] Second trimester serum tests for Down's Syndrome screening
    Alldred, S. K.
    Deeks, J. J.
    Guo, B.
    Neilson, J. P.
    Alfirevic, Z.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (06):
  • [6] [Anonymous], US GLYC HEM HBA DIAG
  • [7] [Anonymous], 1999, WHO TECHN REP SER
  • [8] [Anonymous], CONSENSUS GUIDELINES
  • [9] [Anonymous], DIAB PREGN MAN DIAB
  • [10] [Anonymous], J INT FED CLIN CHEM