A novel concept to include uncertainties in the evaluation of stereotactic body radiation therapy after 4D dose accumulation using deformable image registration

被引:9
|
作者
Diego Azcona, Juan [1 ]
Huesa-Berral, Carlos [1 ,2 ]
Moreno-Jimenez, Marta [3 ]
Barbes, Benigno [1 ]
Javier Aristu, Jose [3 ]
Burguete, Javier [2 ]
机构
[1] Univ Navarra Clin, Serv Radiat Phys & Radiat Protect, Avda Pio XII, Pamplona 31008, Spain
[2] Univ Navarra, Sch Sci, Dept Phys & Appl Math, Navarra 31008, Spain
[3] Clin Univ Navarra, Serv Radiat Oncol, Avda Pio XII, Navarra 31008, Spain
关键词
deformable image registration; dose accumulation; uncertainty; TIME TUMOR-TRACKING; LUNG-CANCER; RADIOTHERAPY; MOTION; ACCURACY; DELINEATION; DEFINITION; COLLIMATOR; VOLUME; SETUP;
D O I
10.1002/mp.13759
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To use four-dimensional (4D) dose accumulation based on deformable image registration (DIR) to assess dosimetric uncertainty in lung stereotactic body radiation therapy (SBRT) treatment planning. A novel concept, the Evaluation Target Volume (ETV), was introduced to achieve this goal. Methods The internal target volume (ITV) approach was used for treatment planning for 11 patients receiving lung SBRT. Retrospectively, 4D dose calculation was done in Pinnacle v9.10. Total dose was accumulated in the reference phase using DIR with MIM. DIR was validated using landmarks introduced by an expert radiation oncologist. The 4D and three-dimensional (3D) dose distributions were compared within the gross tumor volume (GTV) and the planning target volume (PTV) using the D-95 and D-min (calculated as D-min,D-0.035cc) metrics. For lung involvement, the mean dose and V-20, V-10, and V-5 were used in the 3D to 4D dose comparison, and D-max (D-0.1cc) was used for all other organs at risk (OAR). The new evaluation target volume (ETV) was calculated by expanding the GTV in the reference phase in order to include geometrical uncertainties of the DIR, interobserver variability in the definition of the tumor, and uncertainties of imaging and delivery systems. D-95 and D-min,D-0.035cc metrics were then calculated on the basis of the ETV for 4D accumulated dose distributions, and these metrics were compared with those calculated from the PTV for 3D planned dose distributions. Results The target registration error (TRE) per spatial component was below 0.5 +/- 2.1mm for all our patients. For five patients, dose degradation above 2% (>4% in 2 patients) was found in the PTV after 4D accumulation and attributed to anatomical variations due to breathing. Comparison of D-95 and D-min,D-0.035cc metrics showed that the ETV (4D accumulated dose) estimated substantially lower coverage than the PTV (3D planning dose): in six out of the 11 cases, and for at least for one of the two metrics, coverage estimated by ETV was at least 5% lower than that estimated by PTV. Furthermore, the ETV approach revealed hot and cold spots within its boundaries. Conclusions A workflow for 4D dose accumulation based on DIR has been devised. Dose degradation was attributed to respiratory motion. To overcome limitations in the PTV for the purposes of evaluating DIR-based 4D accumulated dose distributions, a new concept, the ETV, was proposed. This concept appears to facilitate more reliable dose evaluation and a better understanding of dosimetric uncertainties due to motion and deformation.
引用
收藏
页码:4346 / 4355
页数:10
相关论文
共 50 条
  • [1] Adaptive Radiation Therapy with Deformable Image Registration and 4D Dose Calculation
    Ali, I.
    Alsbou, N.
    Ahmad, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [2] 4D CT Deformable Registration Using Unsupervised Deep Learning for Lung Stereotactic Body Radiation Therapy
    Yang, X.
    Fu, Y.
    Lei, Y.
    Tian, Z.
    Wang, T.
    Higgins, K. A.
    Shelton, J. W.
    Bradley, J. D.
    Curran, W. J., Jr.
    Liu, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E342 - E343
  • [3] Accumulated Dose Estimation in Lung Stereotactic Body Radiation Therapy Using Deformable Image Registration Algorithm
    Wu, Q.
    Liu, C.
    Devpura, S.
    Ajlouni, M.
    Movsas, B.
    Chetty, I.
    MEDICAL PHYSICS, 2017, 44 (06) : 3222 - 3223
  • [4] A method using 4D dose accumulation to quantify the interplay effect in lung stereotactic body radiation therapy
    Huesa-Berral, Carlos
    Burguete, Javier
    Moreno-Jiménez, Marta
    Azcona, Juan Diego
    Physics in Medicine and Biology, 2021, 66 (03):
  • [5] A method using 4D dose accumulation to quantify the interplay effect in lung stereotactic body radiation therapy
    Huesa-Berral, Carlos
    Burguete, Javier
    Moreno-Jimenez, Marta
    Diego Azcona, Juan
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03):
  • [6] Evaluation of Hepatic Toxicity after Repeated Stereotactic Body Radiation Therapy for Recurrent Hepatocellular Carcinoma using Deformable Image Registration
    Sumin Lee
    Hojin Kim
    Yunseo Ji
    Byungchul Cho
    Su Ssan Kim
    Jinhong Jung
    Jungwon Kwak
    Jin-hong Park
    Sang-wook Lee
    Jong Hoon Kim
    Sang Min Yoon
    Scientific Reports, 8
  • [7] Evaluation of Hepatic Toxicity after Repeated Stereotactic Body Radiation Therapy for Recurrent Hepatocellular Carcinoma using Deformable Image Registration
    Lee, Sumin
    Kim, Hojin
    Ji, Yunseo
    Cho, Byungchul
    Kim, Su Ssan
    Jung, Jinhong
    Kwak, Jungwon
    Park, Jin-Hong
    Lee, Sang-Wook
    Kim, Jong Hoon
    Yoon, Sang Min
    SCIENTIFIC REPORTS, 2018, 8
  • [8] Uncertainties of deformable image registration considering motion: a 4D phantom study
    Guidi, G.
    Maffei, N.
    Mistretta, M. G.
    Vecchi, C.
    Ciarmatori, A.
    Bertoni, F.
    Costi, T.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S845 - S846
  • [9] Evaluation of 4D CT to 4D Cone-Beam CT Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy
    Balik, S.
    Hugo, G.
    Weiss, E.
    Jan, N.
    Roman, N.
    Sleeman, W.
    Fatyga, M.
    Christensen, G.
    Murphy, M.
    Lu, J.
    Keall, P.
    Williamson, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3875 - 3875
  • [10] Image-guided process for 4D lung stereotactic body radiation therapy
    Purdie, T
    Moseley, D
    Sharpe, M
    Bissonnette, J
    Jaffray, D
    MEDICAL PHYSICS, 2005, 32 (06) : 2125 - 2125