Lack of specificity associated with using molecular beacons in loop mediated amplification assays

被引:20
作者
Hardinge, Patrick [1 ]
Murray, James A. H. [1 ]
机构
[1] Cardiff Sch Biosci, Museum Ave, Cardiff CF10 3AX, S Glam, Wales
基金
英国生物技术与生命科学研究理事会;
关键词
Loop-mediated amplification (LAMP); Molecular beacons; DNA; Genetically modified (GM) crops; Fluorescence; POLYMERASE-CHAIN-REACTION; ISOTHERMAL AMPLIFICATION; DNA;
D O I
10.1186/s12896-019-0549-z
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: Loop mediated isothermal amplification of nucleic acid templates is a rapid, sensitive and specific method suitable for molecular diagnostics. However the complexity of primer design and the number of primers involved can lead to false positives from non-specific primer interactions. Standard methods of LAMP detection utilise the increasing concentrations of DNA or inorganic pyrophosphate and therefore lack specificity for identifying the desired LAMP amplification. Molecular beacons used in PCR reactions are target specific and may enhance specificity with LAMP. Results: We present a potential molecular beacon approach to LAMP detection targeting the single stranded region between loops, and test this for LAMP molecular beacons targeting the 35S promoter and NOS terminator sequences commonly used in GM crops. From these studies we show that molecular beacons used in LAMP, despite providing a change in fluorescent intensity with amplification, appear not to anneal to specific target sequences and therefore target specificity is not a benefit of this method. However, molecular beacons demonstrate a change in fluorescence which is indicative of LAMP amplification products. We identify the LAMP loop structure as likely to be responsible for this change in signal. Conclusions: Molecular beacons can be used to detect LAMP amplification but do not provide sequence specificity. The method can be used to determine effectively LAMP amplification from other primer-driven events, but does not discriminate between different LAMP amplicons. It is therefore unsuitable for multiplex LAMP reactions due to non-specific detection of LAMP amplification.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Development of a pair of real -time loop mediated isothermal amplification assays for detection of Yersinia pestis , the causative agent of plague
    Singh, Rita
    Pal, Vijai
    Tripathi, N. K.
    Goel, A. K.
    MOLECULAR AND CELLULAR PROBES, 2020, 54
  • [42] Detecting Fusarium oxysporum f. sp. elaeidis by using loop-mediated isothermal amplification
    Adusei-Fosu, Kwasi
    Dickinson, Matthew
    JOURNAL OF PLANT PATHOLOGY, 2023, 105 (04) : 1637 - 1643
  • [43] Colorimetric Nucleic Acid Detection on Paper Microchip Using Loop Mediated Isothermal Amplification and Crystal Violet Dye
    Roy, Sharmili
    Mohd-Naim, Noor Faizah
    Safavieh, Mohammadali
    Ahmed, Minhaz Uddin
    ACS SENSORS, 2017, 2 (11): : 1713 - 1720
  • [44] Testing the Infection Prevalence of Schistosoma mansoni after Mass Drug Administration by Comparing Sensitivity and Specificity of Species-Specific Repeat Fragment Amplification by PCR and Loop-Mediated Isothermal Amplification
    Price, Miriam
    Cyrs, Austin
    Sikasunge, Chummy S.
    Mwansa, James
    Lodh, Nilanjan
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2019, 101 (01) : 78 - 83
  • [45] Detection of capripoxvirus DNA using a novel loop-mediated isothermal amplification assay
    Lee Murray
    Lorraine Edwards
    Eeva SM Tuppurainen
    Katarzyna Bachanek-Bankowska
    Chris AL Oura
    Valerie Mioulet
    Donald P King
    BMC Veterinary Research, 9
  • [46] Detection of Phytophthora capsici in Irrigation Water using Loop-Mediated Isothermal Amplification
    Hudson, Owen
    Waliullah, Sumyya
    Hand, Justin
    Gazis-Seregina, Romina
    Baysal-Gurel, Fulya
    Ali, Md Emran
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (160):
  • [47] Differential identification of three species of Curtovirus using loop-mediated isothermal amplification
    Kil, E. -J.
    Cho, S. -H.
    Byun, H. -S.
    Kim, J.
    Hwang, H. -S.
    Auh, C. -K.
    Heo, N. -Y.
    Shin, Y. -G.
    Lee, S.
    ACTA VIROLOGICA, 2014, 58 (02) : 160 - 166
  • [48] Rapid and sensitive detection of Acinetobacter baumannii using loop-mediated isothermal amplification
    Soo, Po-Chi
    Tseng, Chun-Chieh
    Ling, Siao-Ru
    Liou, Ming-Li
    Liu, Chih-Chin
    Chao, Huei-Jen
    Lin, Teng-Yi
    Chang, Kai-Chih
    JOURNAL OF MICROBIOLOGICAL METHODS, 2013, 92 (02) : 197 - 200
  • [49] Rapid detection of Heterobasidion annosum using a loop-mediated isothermal amplification assay
    Hong-min, Zhou
    Jian, Yu
    Ying, Liu
    Yuan, Yuan
    Cui-ping, Wu
    Yu-cheng, Dai
    Jia-jia, Chen
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2023, 13
  • [50] Sensitive and rapid detection of Alicyclobacillus acidoterrestris using loop-mediated isothermal amplification
    Chen, Jing
    Ma, Xiaoyan
    Yuan, Yaowu
    Zhang, Wei
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2011, 91 (06) : 1070 - 1074