Luminescence response to irradiation using mini X-ray generators

被引:15
作者
Thomsen, K. J.
Botter-Jensen, L.
Denby, P. M.
Murray, A. S.
机构
[1] Riso Natl Lab, DK-4000 Roskilde, Denmark
[2] Univ Aarhus, Riso Natl Lab, Dept Earth Sci, Nord Lab Luminescence Dating, DK-4000 Roskilde, Denmark
关键词
X-ray; luminescence; OSL;
D O I
10.1016/j.nimb.2006.08.021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Determination of equivalent doses in retrospective dosimetry involves calibration by irradiation of the dosimeters in the laboratory. In the Riso TL/OSL measurement system, laboratory irradiations make use of a radionuclide (Sr-90/Y-90 beta) source. In this paper we investigate the possibility of replacing the radionuclide source with an X-ray tube. Two different X-ray tubes are tested; a filament type (50 kV, 1 mA, 50 W) and a cold cathode type (30 kV, 0. 1 mA, 3 W). We show that the horizontal dose uniformity and irradiation crosstalk are improved compared to the beta source and that the reproducibility is comparable, The relationship between X-ray dose rate and tube current is highly linear for both tubes. OSL decay curves, growth curves and dose distributions from various thermally annealed quartz samples are also presented. Finally it is shown that, unlike for a beta source, the calibration factor obtained using low energy X-rays is sample dependent. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:267 / 275
页数:9
相关论文
共 11 条
[1]   A mini X-ray generator as an alternative to a 90Sr/90Y beta source in luminescence dating [J].
Andersen, CE ;
Botter-Jensen, L ;
Murray, AS .
RADIATION MEASUREMENTS, 2003, 37 (4-5) :557-561
[2]  
Ballarini M., 2006, ANCIENT TL, V24, P1
[3]  
BOS AJJ, IN PRESS RAD MEASURE
[4]   Advances in luminescence instrument systems [J].
Botter-Jensen, L ;
Bulur, E ;
Duller, GAT ;
Murray, AS .
RADIATION MEASUREMENTS, 2000, 32 (5-6) :523-528
[5]   An automated system for both red/blue thermoluminescence and optically stimulated luminescence measurement [J].
Hashimoto, T ;
Nakagawa, T ;
Hong, DG ;
Takano, M .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2002, 39 (01) :108-109
[6]  
HELTHANSEN J, RISOSCAN 2 02 SOFTWA
[7]   Optimum aluminum absorber thickness of a small X-ray irradiator for equivalent dose determination [J].
Hong, DG ;
Kim, MJ ;
Yawata, T ;
Hashimoto, T .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 265 (03) :495-498
[8]  
JAIN M, IN PRESS RAD MEASURE
[9]  
JAIN M, UNPUB J PHYS CONDENS
[10]   Luminescence dating of quartz using an improved single-aliquot regenerative-dose protocol [J].
Murray, AS ;
Wintle, AG .
RADIATION MEASUREMENTS, 2000, 32 (01) :57-73