In this paper, a method for the condition monitoring of the gate-oxide degradation in silicon carbide (SiC) metal-oxide-semiconductor-field-effect transistors (MOSFETs) is presented. To identify the gate-oxide degradation in SiC MOSFETs, a high-temperature gate bias (HTGB) test, which is an accelerated aging test, is usually performed. This paper proposes an advanced HTGB test for power devices. The test is suitable for developing a condition monitoring system for power devices because the test can accelerate the device aging under switching conditions. Electrical parameter changes in the SiC MOSFETs are demonstrated in the test results. Furthermore, a condition monitoring technique using the input capacitance C-iss change of the SiC MOSFETs is proposed.
机构:
City Univ Hong Kong, Dept Elect Engn, Ctr Smart Energy Convers & Utilizat Res, Kowloon Tong,Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Elect Engn, Ctr Smart Energy Convers & Utilizat Res, Kowloon Tong,Kowloon, Hong Kong, Peoples R China
Tang, Ho-Tin
Chung, Henry Shu-Hung
论文数: 0引用数: 0
h-index: 0
机构:
City Univ Hong Kong, Dept Elect Engn, Ctr Smart Energy Convers & Utilizat Res, Kowloon Tong,Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Elect Engn, Ctr Smart Energy Convers & Utilizat Res, Kowloon Tong,Kowloon, Hong Kong, Peoples R China
Chung, Henry Shu-Hung
Chen, Kevin Jing
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Univ Sci & Technol, Dept Elect & Comp Engn, Clear Water Bay, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Elect Engn, Ctr Smart Energy Convers & Utilizat Res, Kowloon Tong,Kowloon, Hong Kong, Peoples R China