Background: It is unclear whether stemless shoulder prosthesis lead to better clinical outcomes than conventional stemmed shoulder prosthesis. The purpose is to compare clinical outcomes and complication rates after surgery in patients with shoulder arthropathy treated with stemless or conventional stemmed shoulder prosthesis. Method: All studies comparing the constant score (CS), range of motion (ROM), and complication rates after surgery in patients with shoulder arthropathy treated with stemless or conventional stemmed shoulder prosthesis were included. The major databases MEDLINE, EMBASE, the Cochrane Library, Web of Science, and SCOPUS were searched for appropriate studies from the earliest available date of indexing through March 31, 2019. No restrictions were placed on language of publication. Results: A total of 6 studies met the inclusion criteria and were analyzed in detail. Overall postoperative ROM (95% CI: 3.27 to 11.92; P < .01) was significantly greater for stemless prosthesis compared to conventional stemmed prosthesis. However, postoperative CS (95% CI: -2.98 to 7.13; P = .42) and complication rates (OR 1.22, 95% CI: 0.48-3.08; P = .68) were did not differ significantly between the 2 groups. Conclusion: This meta-analysis revealed that postoperative CS and complication rates did not differ significantly between the 2 treatment methods, stemless shoulder prosthesis and conventional stemmed shoulder prosthesis, for shoulder arthropathy. However, stemless shoulder prosthesis resulted in better outcomes than conventional stemmed shoulder prosthesis in terms of postoperative ROM.
引用
收藏
页数:8
相关论文
共 23 条
  • [1] Periprosthetic Humeral Fractures During Shoulder Arthroplasty
    Athwal, George S.
    Sperling, John W.
    Rispoli, Damian M.
    Cofield, Robert H.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (03) : 594 - 603
  • [2] Posterior-stabilized inserts are preferable to cruciate-substituting ultracongruent inserts due to more favourable kinematics and stability
    Bae, Ji-Hoon
    Yoon, Jung-Ro
    Sung, Ju-Hyoung
    Shin, Young-Soo
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (11) : 3300 - 3310
  • [3] Long-term survivorship of stemless anatomical shoulder replacement
    Beck, Sascha
    Beck, Verena
    Wegner, Alexander
    Dudda, Marcel
    Patsalis, Theodor
    Jaeger, Marcus
    [J]. INTERNATIONAL ORTHOPAEDICS, 2018, 42 (06) : 1327 - 1330
  • [4] Stemless shoulder prosthesis versus conventional anatomic shoulder prosthesis in patients with osteoarthritis: A comparison of the functional outcome after a minimum of two years follow-up
    Berth A.
    Pap G.
    [J]. Journal of Orthopaedics and Traumatology, 2013, 14 (1) : 31 - 37
  • [5] Clinical and Radiographic Outcomes of the Simpliciti Canal-Sparing Shoulder Arthroplasty System A Prospective Two-Year Multicenter Study
    Churchill, R. Sean
    Chuinard, Christopher
    Wiater, J. Michael
    Friedman, Richard
    Freehill, Michael
    Jacobson, Scott
    Spencer, Edwin, Jr.
    Holloway, G. Brian
    Wittstein, Jocelyn
    Lassiter, Tally
    Smith, Matthew
    Blaine, Theodore
    Nicholson, Gregory P.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (07) : 552 - 560
  • [6] Stemless shoulder arthroplasty—current results and designs
    Churchill R.S.
    Athwal G.S.
    [J]. Current Reviews in Musculoskeletal Medicine, 2016, 9 (1) : 10 - 16
  • [7] Midterm results of stemless shoulder arthroplasty: a prospective study
    Habermeyer, Peter
    Lichtenberg, Sven
    Tauber, Mark
    Magosch, Petra
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (09) : 1463 - 1472
  • [8] Nine-year outcome after anatomic stemless shoulder prosthesis: clinical and radiologic results
    Hawi, Nael
    Magosch, Petra
    Tauber, Mark
    Lichtenberg, Sven
    Habermeyer, Peter
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (09) : 1609 - 1615
  • [9] Results of a new stemless shoulder prosthesis: Radiologic proof of maintained fixation and stability after a minimum of three years' follow-up
    Huguet, Dominique
    DeClercq, Geert
    Rio, Bruno
    Teissier, Jacques
    Zipoli, Bruno
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (06) : 847 - 852
  • [10] Humeral component revision arthroplasty: outcomes of a split osteotomy technique
    Johnston, Peter S.
    Creighton, R. Alexander
    Romeo, Anthony A.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (04) : 502 - 506