Quantification of microbubble destruction of three fluorocarbon-filled ultrasonic contrast agents

被引:37
作者
Moran, CM [1 ]
Anderson, T [1 ]
Pye, SD [1 ]
Sboros, V [1 ]
McDicken, WN [1 ]
机构
[1] Univ Edinburgh, Dept Med Phys & Med Engn, Edinburgh EH3 9YW, Midlothian, Scotland
关键词
ultrasound; ultrasonic contrast agents; DMP115; Definity (R); Sonazoid (R); NC100100; Optison (R); tissue-mimicking phantom; echocardiography;
D O I
10.1016/S0301-5629(00)00148-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The assessment of myocardial blood velocity using ultrasonic contrast agents is based on the premise that the vast majority of contrast microbubbles within a myocardial region can be destroyed by an acoustic pulse of sufficient magnitude. Determination of the period of time after destruction that a region of myocardium needs to reperfuse may be used to assess myocardial blood velocity. In this study, we investigated the acoustic pressure sensitivity of three solutions of intravenous fluorocarbon-filled contrast agents and the magnitude of acoustic pulse required to destroy the contrast agent microbubbles. A novel tissue-mimicking phantom was designed and manufactured to investigate the relationships between mean integrated backscatter, incident acoustic pressure and number of frames of insonation for three fluorocarbon-filled contrast agents (Definity(R), Optison(R), and Sonazoid(R), formerly NC100100), Using a routine clinical ultrasound (US) scanner (Acuson XP-10), modified to allow access to the unprocessed US data, the contrast agents were scanned at the four acoustic output powers. All three agents initially demonstrated a linear relationship between mean integrated backscatter and number of frames of insonation. For all three agents, mean integrated backscatter decreased more rapidly at higher acoustic pressures, suggesting a more rapid destruction of the microbubbles, In spite of the fact that there was no movement of microbubbles into or out of the beam, only the results from Definity(R) suggested that a complete destruction of the contrast agent microbubbles had occurred within the total duration of insonation in this study, (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:629 / 639
页数:11
相关论文
共 19 条
[1]  
CHANG PH, 1995, IEEE T ULTRASON FERR, V42, P1020
[2]   THE EFFECTS OF AN ELASTIC SOLID-SURFACE LAYER ON THE RADIAL PULSATIONS OF GAS-BUBBLES [J].
CHURCH, CC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (03) :1510-1521
[3]   Optical and acoustical observations of the effects of ultrasound on contrast agents [J].
Dayton, PA ;
Morgan, KE ;
Klibanov, AL ;
Brandenburger, GH ;
Ferrara, KW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (01) :220-232
[4]  
DeMaria AN, 1998, J AM COLL CARDIOL, V32, P1270
[5]   Scattering properties of encapsulated gas bubbles at high ultrasound pressures [J].
Frinking, PJA ;
de Jong, N ;
Céspedes, EI .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (03) :1989-1996
[6]   Direct video microscopic observation of the dynamic effects of medical ultrasound on ultrasound contrast microspheres [J].
Klibanov, AL ;
Ferrara, KW ;
Hughes, MS ;
Wible, JH ;
Wojdyla, JK ;
Dayton, PA ;
Morgan, KE ;
Brandenburger, GH .
INVESTIGATIVE RADIOLOGY, 1998, 33 (12) :863-870
[7]   Assessment of transmural distribution of myocardial perfusion with contrast echocardiography [J].
Linka, AZ ;
Sklenar, J ;
Wei, K ;
Jayaweera, AR ;
Skyba, DM ;
Kaul, S .
CIRCULATION, 1998, 98 (18) :1912-1920
[8]   Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice - Comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography [J].
Marwick, TH ;
Brunken, R ;
Meland, N ;
Brochet, E ;
Baer, FM ;
Binder, T ;
Flachskampf, F ;
Kamp, O ;
Nienaber, C ;
Nihoyannopoulos, P ;
Pierard, L ;
Vanoverschelde, JL ;
van der Wouw, P ;
Lindvall, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) :1260-1269
[9]   Quantification of the enhanced backscatter phenomenon from an intravenous and an intra-arterial contrast agent [J].
Moran, CM ;
Anderson, T ;
Sboros, V ;
Sutherland, GR ;
Wright, R ;
McDicken, WN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06) :871-880
[10]   Potential advantage of flash echocardiography for digital subtraction of B-mode images acquired during myocardial contrast echocardiography [J].
Pelberg, RA ;
Wei, K ;
Kamiyama, N ;
Sklenar, J ;
Bin, JP ;
Kaul, S .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (02) :85-93