FIB-TEM Study of Magnesium Corrosion Products after 14 Days in the Murine Artery

被引:21
作者
Bowen, Patrick K. [1 ]
McNamara, Cameron T. [1 ]
Mills, Owen P. [1 ,2 ]
Drelich, Jaroslaw [1 ]
Goldman, Jeremy [3 ]
机构
[1] Michigan Technol Univ, Dept Mat Sci & Engn, Houghton, MI 49331 USA
[2] Michigan Technol Univ, Appl Chem & Morphol Anal Lab, Houghton, MI 49331 USA
[3] Michigan Technol Univ, Dept Biomed Engn, Houghton, MI 49331 USA
关键词
bioabsorbable stent; magnesium; corrosion products; in vivo; INTRAVASCULAR ULTRASOUND; BIODEGRADABLE STENTS; CORONARY-ARTERIES; ALLOY STENTS; IMPLANTATION; BIOCORROSION; DEGRADATION; BEHAVIOR; METAL;
D O I
10.1021/acsbiomaterials.5b00044
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
After a decade of intensive research on magnesium biodegradation, the composition and structure of corrosion products formed during in vivo corrosion are still not precisely known. Focused ion beam (FIB) micromilling and transmission electron microscopy (TEM) were used to elucidate the nanostructure and crystallography of the corrosion products that form at or near the interface between the corrosion products and metallic magnesium. This study built upon previously reported scanning electron microscopy, infrared spectroscopy, and energy dispersive X-ray spectroscopy data. These prior results revealed a duplex corrosion layer comprising a calcium- and phosphorus-containing outer product (near the tissue interface) and a magnesium- and oxygen-containing inner product (near the metallic interface). A specimen that had resided in the murine arterial wall for 14 days was selected for FIB-TEM analysis. Highly oriented, nanocrystalline magnesium oxide was identified near the metallic magnesium, apparently without the co-occurrence of magnesium hydroxide or carbonates. The calcium- and phosphorus-containing surface layer was also examined, and shown to be nearly amorphous.
引用
收藏
页码:919 / 926
页数:8
相关论文
共 47 条
[1]  
[Anonymous], 2013, AN PHYS
[2]  
Barsoum M, 2002, FUNDAMENTALS CERAMIC
[3]  
Black J., 1999, Biological Performance of Materials: Fundamentals of Biocompatibility, V3rd
[4]   Rates of in vivo (arterial) and in vitro biocorrosion for pure magnesium [J].
Bowen, Patrick K. ;
Drelich, Adam ;
Drelich, Jaroslaw ;
Goldman, Jeremy .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2015, 103 (01) :341-349
[5]   Magnesium in the murine artery: Probing the products of corrosion [J].
Bowen, Patrick K. ;
Drelich, Jaroslaw ;
Goldman, Jeremy .
ACTA BIOMATERIALIA, 2014, 10 (03) :1475-1483
[6]   Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents [J].
Bowen, Patrick K. ;
Drelich, Jaroslaw ;
Goldman, Jeremy .
ADVANCED MATERIALS, 2013, 25 (18) :2577-2582
[7]   Film Breakdown and Nano-Porous Mg(OH)2 Formation from Corrosion of Magnesium Alloys in Salt Solutions [J].
Brady, M. P. ;
Rother, G. ;
Anovitz, L. M. ;
Littrell, K. C. ;
Unocic, K. A. ;
Elsentriecy, H. H. ;
Song, G. -L. ;
Thomson, J. K. ;
Gallego, N. C. ;
Davis, B. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (04) :C140-C149
[8]  
Di Mario Carlo, 2004, J Interv Cardiol, V17, P391, DOI 10.1111/j.1540-8183.2004.04081.x
[9]   Biodegradable stents: the golden future of angioplasty? [J].
Di Mario, Carlo ;
Caiazzo, Gianluca .
LANCET, 2015, 385 (9962) :10-12
[10]   Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents:: a prospective, non-randomised multicentre trial [J].
Erbel, Raimund ;
Di Mario, Carlo ;
Bartunek, Jozef ;
Bonnier, Johann ;
de Bruyne, Bernard ;
Eberli, Franz R. ;
Erne, Paul ;
Haude, Michael ;
Heublein, Bernd ;
Horrigan, Mark ;
Ilsley, Charles ;
Boese, Dirk ;
Koolen, Jacques ;
Luescher, Thomas F. ;
Weissman, Neil ;
Waksman, Ron .
LANCET, 2007, 369 (9576) :1869-1875