Design and optimization of a dual-energy gas microstrip detector

被引:0
作者
Giakos, GC
Dasgupta, A
Chowdhury, S
机构
来源
IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2 | 1997年
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The design principles and optimization procedures of a novel digital radiographic technique for dual-energy imaging based on gas microstrip hybrid detection principles are presented and analyzed. The detector consists of a solid state crystal coupled to a gas microstrip substrate. The proposed technology combines the high quantum detection efficiency of the solid state materials with the high gain and submicron resolution of the microstrip substrate. By simultaneously providing high spatial resolution and high contrast resolution it is expected that the dual-energy gas microstrip hybrid digital radiographic detector will have potential impact in medical diagnosis and treatment follow-up.
引用
收藏
页码:2 / 7
页数:6
相关论文
共 50 条
  • [21] Feasibility of using a kinestatic charge detector for dual-energy chest radiography
    Schmithorst, Vincent J.
    Endorf, Robert J.
    Kulatunga, Sunil
    Spelic, David C.
    DiBianca, Frank A.
    Rodriguez, Carlos
    Zeman, Herbert D.
    Zhu, Zeping
    Giakos, George C.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2004, 12 (01) : 1 - 11
  • [22] CZT detector for dual-energy x-ray absorptiometry (DEXA)
    Wear, J
    Buchholz, M
    Payne, R
    Gorsuch, D
    Bisek, J
    Ergun, D
    Grosholz, J
    Falk, R
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 175 - 188
  • [23] NOISE CORRELATIONS IN IMAGES ACQUIRED SIMULTANEOUSLY WITH A DUAL-ENERGY SANDWICH DETECTOR
    SONES, RA
    BARNES, GT
    MEDICAL PHYSICS, 1989, 16 (06) : 858 - 861
  • [24] Dual-energy Radiographic Absorptiometry of the phalanges using a pixelated area detector
    Smith, JE
    Karellas, A
    Levis, I
    Vedantham, S
    Edelstein, D
    RADIOLOGY, 1998, 209P : 359 - 359
  • [25] Evaluation of dual-energy radiography with a digital X-Ray detector
    Guillemaud, R
    Robert-Coutant, C
    Darboux, M
    Gagelin, JJ
    Dinten, JM
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 469 - 478
  • [26] OPERATION OF THE MICROSTRIP GAS DETECTOR
    HARTJES, F
    HENDRIKSEN, B
    SCHMITZ, J
    SCHMITZ, J
    SCHUIJLENBURG, H
    UDO, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2) : 88 - 94
  • [27] A PROTOTYPE MICROSTRIP GAS DETECTOR
    HARTJES, F
    HENDRIKSEN, B
    UDO, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 289 (03) : 384 - 387
  • [28] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Okayama, Satoshi
    Seno, Ayako
    Soeda, Tsunenari
    Takami, Yasuhiro
    Kawakami, Rika
    Somekawa, Satoshi
    Ishigami, Ken-ichi
    Takeda, Yukiji
    Kawata, Hiroyuki
    Horii, Manabu
    Uemura, Shiro
    Saito, Yoshihiko
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04) : 901 - 909
  • [29] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Satoshi Okayama
    Ayako Seno
    Tsunenari Soeda
    Yasuhiro Takami
    Rika Kawakami
    Satoshi Somekawa
    Ken-ichi Ishigami
    Yukiji Takeda
    Hiroyuki Kawata
    Manabu Horii
    Shiro Uemura
    Yoshihiko Saito
    The International Journal of Cardiovascular Imaging, 2012, 28 : 901 - 909
  • [30] Optimization of microstrip gas chamber design and operating conditions
    Beckers, T.
    Bouclier, R.
    Garabatos, Ch.
    Million, G.
    Sauli, F.
    Shekhtman, L.I.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A346 (1-2) : 95 - 101