Adequacy and Diagnostic Accuracy of Aspiration vs. Capillary Fine Needle Thyroid Biopsies

被引:19
作者
de Carvalho, Gisah Amaral [1 ]
Paz-Filho, Gilberto [1 ]
Cavalcanti, Teresa C. [2 ]
Graf, Hans [1 ]
机构
[1] Univ Fed Parana, Hosp Clin, SEMPR Serv Endocrinol & Metab, BR-80060000 Curitiba, Parana, Brazil
[2] Univ Fed Parana, Hosp Clin, Dept Anat Patol, BR-80060000 Curitiba, Parana, Brazil
关键词
aspiration; biopsy; capillary; fine needle; goiter; nodule; thyroid; NODULES; NONASPIRATION; CYTOLOGY; LESIONS;
D O I
10.1007/s12022-009-9092-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Thyroid nodules can be biopsied by fine needle aspiration (FNA) or fine needle capillary (FNC) biopsies. However, there is controversy on whether one technique is superior to another. In a randomized cytopathologist-blinded cross-sectional study, 260 patients (238 females, age 43.2 +/- 12.6) with nodular (82.7%) and diffuse goiter (17.3%) underwent 520 FNAs and 520 FNCs (not guided by ultrasound). Smears were scored for sample adequacy, and diagnosed as malignant, benign, suspicious, or nondiagnostic. Diagnostic accuracy was calculated based on the histological findings of 58 patients submitted to surgery. Intra-technique diagnostic accuracy and sample adequacy was seen in all samples. FNA and FNC provided similar cytological diagnosis, respectively (benign: 75.8% vs. 74.2%, p = 0.600; malignant: 3.8% vs. 3.8%, p = 0.871; suspicious: 10.4% vs. 10.8%, p = 0.913; and nondiagnostic: 10.0% vs. 11.2%, p = 0.598). Adequacy scores were similar by FNA (7.94 +/- 2.84) and FNC (7.96 +/- 2.81, p = 0.909). The same proportion of adequate or superior samples was seen in both techniques (91.6%). Sensitivity was equal to 85.7% for FNA and 100% for FNC. Similarly, specificity was 100% for both techniques. FNA and FNC provide the similar sample adequacy and diagnostic accuracy. The choice of technique should be based on the operator's personal preferences and experience.
引用
收藏
页码:204 / 208
页数:5
相关论文
共 14 条
[1]   Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material [J].
Degirmenci, B. ;
Haktanir, A. ;
Albayrak, R. ;
Acar, M. ;
Sahin, D. A. ;
Sahin, O. ;
Yucel, A. ;
Caliskan, G. .
CLINICAL RADIOLOGY, 2007, 62 (08) :798-803
[2]   Comparison of fine-needle-nonaspiration with fine-needle-aspiration technique in the cytologic studies of thyroid nodules [J].
Haddadi-Nezhad, S ;
Larijani, B ;
Tavangar, SM ;
Nouraei, SM .
ENDOCRINE PATHOLOGY, 2003, 14 (04) :369-373
[3]   Comparative study of fine needle aspiration and fine needle capillary sampling of thyroid lesions [J].
Kamal, MM ;
Arjune, DG ;
Kulkarni, HR .
ACTA CYTOLOGICA, 2002, 46 (01) :30-34
[4]   Evaluation of fine needle capillary sampling in superficial and deep-seated lesions - An analysis of 670 cases [J].
Kate, MS ;
Kamal, MM ;
Bobhate, SK ;
Kher, AV .
ACTA CYTOLOGICA, 1998, 42 (03) :679-684
[5]   Unsatisfactory consequences from fine-needle aspiration biopsy of thyroid nodules [J].
Leung, Angela M. ;
Farwell, Alan P. .
THYROID, 2008, 18 (05) :491-492
[6]   Fine-needle aspiration biopsy of benign thyroid nodules: An evidence-based review [J].
Lundgren, Catharina Ihre ;
Zedenius, Jan ;
Skoog, Lambert .
WORLD JOURNAL OF SURGERY, 2008, 32 (07) :1247-1252
[7]  
MAIR S, 1989, ACTA CYTOL, V33, P809
[8]   DIAGNOSTIC UTILITY OF FINE-NEEDLE SAMPLING WITHOUT ASPIRATION - A PROSPECTIVE-STUDY [J].
RAJASEKHAR, A ;
SUNDARAM, C ;
CHOWDHARY, T ;
CHARANPAL, M ;
RATNAKAR, KS .
DIAGNOSTIC CYTOPATHOLOGY, 1991, 7 (05) :473-476
[9]  
SANTOS JEC, 1988, ACTA CYTOL, V32, P353
[10]   Ultrasound-Guided Biopsy of the Thyroid: A Comparison of Technique With Respect to Diagnostic Accuracy [J].
Schoedel, Karen E. ;
Tublin, Mitchell E. ;
Pealer, Karen ;
Ohori, N. Paul .
DIAGNOSTIC CYTOPATHOLOGY, 2008, 36 (11) :787-789