Determination of Thermal Diffusivity/conductivity of Oxide Scale Formed on Steel Plate by Laser Flash Method through Thermal Effusivity Measurement by Transient Hot-strip Method

被引:8
作者
Endo, Rie [1 ]
Hayashi, Hiroki [2 ]
Li, Mu [3 ]
Akoshima, Megumi [3 ]
Okada, Hikaru [4 ]
Tanei, Hiroshi [5 ]
Hayashi, Miyuki [1 ]
Susa, Masahiro [1 ]
机构
[1] Tokyo Inst Technol, Dept Mat Sci & Engn, Meguro Ku, Tokyo 1528552, Japan
[2] Toyo Inst Technol, Dept Met & Ceram Sci, Tokyo 1528552, Japan
[3] Natl Inst Adv Ind Sci & Technol, Res Inst Mat & Chem Measurement, Tsukuba, Ibaraki 3058563, Japan
[4] Nippon Steel Technol Co Ltd, Environm & Energy Conservat Technol Div, 3 Hikari, Kashima, Ibaraki 3140014, Japan
[5] Nippon Steel Corp Ltd, Proc Res Labs, 20-1 Shintomi, Futtsu, Chiba 2938511, Japan
关键词
thermal diffusivity; thermal effusivity; thermal conductivity; oxide scale; Fe1-xO scale; HEAT-TRANSFER; DIFFUSIVITY MEASUREMENT; IRON-OXIDE; FEO SCALE; TEMPERATURE; CONDUCTIVITY; TRANSFORMATION; BEHAVIOR;
D O I
10.2355/isijinternational.ISIJINT-2020-163
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Thermal diffusivity and conductivity were determined for oxide scale formed on steel plate by the laser flash method in combination with thermal effusivity measurement by the transient hot-strip method. The thermal effusivity measurement technique was confirmed by measurement of silica glass, and the value was determined to be 2.52 kJ m(-2) S-1/2 K-1 for the oxide scale formed on an ultra-low-carbon steel plate by oxidation in air at 900 degrees C for 3 600 s. Thermal diffusivity measurements were also conducted for 1 mm-thick steel plates oxidized in air at 900 degrees C for 770-3 600 s by the laser flash method. The apparent thermal diffusivity of samples provided the thermal diffusivity of the oxide scale based on three-layered analysis by inputting the measured value of the thermal effusivity. The measured values suggested that no significant boundary resistance exists between the oxide scale and the steel plate. The thermal conductivity and diffusivity of the oxide scale were calculated to be 1.6 W m(-1) K-1 and 4.0 x 10(-7) m(2) s(-1), respectively.
引用
收藏
页码:2773 / 2779
页数:7
相关论文
共 28 条
[1]   MEASUREMENT AND MODELING OF THERMAL-CONDUCTIVITY FOR DENSE IRON-OXIDE AND POROUS IRON-ORE AGGLOMERATES IN STEPWISE REDUCTION [J].
AKIYAMA, T ;
OHTA, H ;
TAKAHASHI, R ;
WASEDA, Y ;
YAGI, J .
ISIJ INTERNATIONAL, 1992, 32 (07) :829-837
[2]   Thermal Diffusivity Measurement for Thermal Spray Coating Attached to Substrate Using Laser Flash Method [J].
Akoshima, Megumi ;
Tanaka, Takashi ;
Endo, Satoshi ;
Baba, Tetsuya ;
Harada, Yoshio ;
Kojima, Yoshitaka ;
Kawasaki, Akira ;
Ono, Fumio .
JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (11)
[3]  
[Anonymous], 2008, THERMOPHYSICAL PROPE, P271
[4]  
[Anonymous], 2016, 185552016 ISO
[5]  
Birks N., 1983, INTRO HIGH TEMPERATU, P75
[6]   Effects of oxide layer on Leidenfrost temperature during spray cooling of steel at high temperatures [J].
Chabicovsky, M. ;
Hnizdil, M. ;
Tseng, A. A. ;
Raudensky, M. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 88 :236-246
[7]   Thermal Diffusivity Measurement of Oxide Scale Formed on Steel during Hot-rolling Process [J].
Endo, Rie ;
Yagi, Takashi ;
Ueda, Mitsutoshi ;
Susa, Masahiro .
ISIJ INTERNATIONAL, 2014, 54 (09) :2084-2088
[8]   STOICHIOMETRIC FEO AS METASTABLE INTERMEDIATE OF DECOMPOSITION OF WUSTITE AT 225 DEGREES C [J].
HENTSCHEL, B .
ZEITSCHRIFT FUR NATURFORSCHUNG PART A-ASTROPHYSIK PHYSIK UND PHYSIKALISCHE CHEMIE, 1970, A 25 (12) :1996-+
[9]  
Japan Society of Thermophysical Properties, 2008, THERMOPHYSICAL PROPE, P292
[10]  
Japan Society of Thermophysical Properties, 2008, THERMOPHYSICAL PROPE, P210