共 28 条
Validation of visual acuity applications for teleophthalmology during COVID-19
被引:27
作者:
Satgunam, Prem Nandhini
[1
]
Thakur, Monika
[1
]
Sachdeva, Virender
[2
]
Reddy, Sneha
[3
]
Rani, Padmaja Kumari
[4
]
机构:
[1] LV Prasad Eye Inst, Brien Holden Inst Optometry & Vis Sci, Hyderabad Eye Res Fdn, Hyderabad, India
[2] LV Prasad Eye Inst, Child Sight Inst, Nimmagadda Prasad Childrens Eye Care Ctr, Visakhapatnam, Andhra Pradesh, India
[3] LV Prasad Eye Inst, Ctr Innovat, Hyderabad, India
[4] LV Prasad Eye Inst, Teleophthalmol LVPEI Network, Smt Kanuri Santhamma Ctr Vitreo Retinal Dis, Hyderabad 34, Telangana, India
关键词:
Smartphone;
tele-ophthalmology;
tele-optometry;
vision testing;
visual acuity Apps;
DIABETIC-RETINOPATHY;
TELE-OPHTHALMOLOGY;
TELEMEDICINE;
RELIABILITY;
SYSTEM;
D O I:
10.4103/ijo.IJO_2333_20
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
Purpose: The objective of this study was to identify and validate smartphone-based visual acuity (VA) apps that can be used in a teleophthalmology portal. Methods: The study was conducted in three phases: A survey to investigate if the SmartOptometry App was easy to download, understand and test (phase I), an in-clinic comparison of VA measured in a random testing order with four tools namely COMPlog, Reduced Snellen near vision, Peek Acuity (Distance VA) and SmartOptometry (Near VA) (phase II) and a repeatability study on these 4 tools by measuring VA again (phase III). The study recruited the employees of our institute and adhered to the strict COVID-19 protocols of testing. Results: Phase I Survey (n = 40) showed 90% of participants used android phones, 60% reported that instructions were clear, and all users were able to self-assess their near VA with SmartOptometry App. Phase II (n = 68) revealed that Peek Acuity was comparable to COMPlog VA (P = 0.31), however SmartOptometry was statistically significantly different (within 2 log MAR lines) from Reduced Snellen near vision test, particularly for young (n = 44, P = 0.004) and emmetropic (n = 16, P = 0.04) participants. All the 4 tests were found to be repeatable in phase III (n = 10) with a coefficient of repeatability =0.14. Conclusion: Smartphone-based apps were easy to download and can be used for checking patient's distance and near visual acuity. An effect of age and refractive error should be considered when interpreting the results. Further studies with real-time patients are required to identify potential benefits and challenges to solve.
引用
收藏
页码:385 / 390
页数:6
相关论文