Improvement of the Tissue-adhesive and Sealing Effect of Fibrin Sealant Using Polyglycolic Acid Felt

被引:19
作者
Shinya, Noriko [1 ]
Oka, Shirou [1 ]
Miyabashira, Sumika [1 ]
Kaetsu, Hiroshi [1 ]
Uchida, Takanori [1 ]
Sueyoshi, Masuo [2 ]
Takase, Kozo [3 ]
Akuzawa, Masao [3 ]
Miyamoto, Atsushi [3 ]
Shigaki, Takamichi [1 ]
机构
[1] Chemosero Therapeut Res Inst KAKETSUKEN, Kumamoto 8691298, Japan
[2] Miyazaki Univ, Nishi Miyazaki 8892192, Japan
[3] Kagoshima Univ, Kagoshima 8690065, Japan
关键词
fibrin sealant; polyglycolic acid felt; biocompatibility; biomaterial; adhesive force; sealing effect; CEREBROSPINAL-FLUID LEAKAGE; DEVICE; GLUE;
D O I
10.1080/08941930903214743
中图分类号
R61 [外科手术学];
学科分类号
摘要
Although fibrin sealant (FS) has an advantage of high biocompatibility, its adhesive force and sealing effect have been generally considered to be inadequate. In the present study, a high adhesive force and sealing effect were obtained by first rubbing fibrinogen solution into the target tissue, attaching polyglycolic acid (PGA) felt to the treated area, and finally spraying it with FS. This method was compared with three conventional FS application methods and a method using fibrin glue-coated collagen fleece. The adhesive force resulting from the present method was 12 times higher than that for the sequential application method, 4.5 times higher than the spray method, 2.5 times higher than the rubbing and spray method, and 2.2 times higher than the use of fibrin glue-coated collagen fleece. The high adhesive force of FS with PGA felt seemed to be due the high fibrin content of the fibrin gel (FG). Light and electron microscopic observations suggested that the formation of FG in closer contact with the muscle fibers was a factor contributing to this superior adhesive force. Comparison of the sealing effect of the present method with other methods using various biomaterials in combination with FS showed that the sealing effect of FS with PGA felt was 1.4 times higher that of polyglactin 910, 1.8 times that of polytetrafluoroethylene, and 6.7 times that of oxidized regenerated cellulose.
引用
收藏
页码:383 / 389
页数:7
相关论文
共 23 条
[1]   COMPARATIVE-STUDY OF BIOLOGICAL GLUES - CRYOPRECIPITATE GLUE, 2-COMPONENT FIBRIN SEALANT, AND FRENCH GLUE [J].
BASU, S ;
MARINI, CP ;
BAUMANN, FG ;
SHIRAZIAN, D ;
DAMIANI, P ;
ROBERTAZZI, R ;
JACOBOWITZ, IJ ;
ACINAPURA, A ;
CUNNINGHAM, JN .
ANNALS OF THORACIC SURGERY, 1995, 60 (05) :1255-1262
[2]  
BLOMBACK B, 1957, ARK KEMI, V10, P415
[3]  
Chang Huang, 1992, Journal of the Formosan Medical Association, V91, P601
[4]   Effective application of fibrin sealant using a spray device with a double-tube structure [J].
Fukunaga, N ;
Uchida, T ;
Kaetsu, H ;
Kawakami, K ;
Ishihara, Y ;
Funatsu, A .
INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 1998, 18 (05) :345-349
[5]  
Gika Masatoshi, 2007, Interact Cardiovasc Thorac Surg, V6, P12
[6]   Fibrin sealant: Current and potential clinical applications [J].
Jackson, MR ;
MacPhee, MJ ;
Drohan, WN ;
Alving, BM .
BLOOD COAGULATION & FIBRINOLYSIS, 1996, 7 (08) :737-746
[7]   Increased effectiveness of fibrin sealant with a higher fibrin concentration [J].
Kaetsu, H ;
Uchida, T ;
Shinya, N .
INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2000, 20 (01) :27-31
[8]   The seating effect of fibrin glue against alveolar air leakage evaluated up to 48 h; comparison between different methods of application [J].
Kawamura, M ;
Gika, M ;
Izumi, Y ;
Horinouchi, H ;
Shinya, N ;
Mukai, M ;
Kobayashi, K .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (01) :39-42
[9]   Staple-line reinforcement with a new type of polyglycolic acid felt [J].
Kawamura, M ;
Kase, K ;
Sawafuji, M ;
Watanabe, M ;
Horinouchi, H ;
Kobayashi, K .
SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2001, 11 (01) :43-46
[10]  
KOBAYASHI T, 2002, J NEW REM CLIN, V51, P58