Determination of Volatile Organic Compounds in Indoor Air in the Gdansk Area Using Permeation Passive Samplers

被引:7
作者
Zabiegala, Bozena [1 ]
Partyka, Monika [1 ]
Zygmunt, Bogdan [1 ]
Namiesnik, Jacek [1 ]
机构
[1] Gdansk Univ Technol, Dept Analyt Chem, Fac Chem, PL-80233 Gdansk, Poland
关键词
indoor air quality; volatile organic compounds; retention index; sampling; permeation passive samplers; gas chromatography; RETENTION INDEX SYSTEM; OUTDOOR; CALIBRATION; EXPOSURE; QUALITY;
D O I
10.1177/1420326X09336550
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Passive dosimetry - known for over a hundred years is still a useful tool in monitoring air pollutants. In this work, permeation passive samplers were used to determine indoor air quality in 22 apartments located in the Gdansk area in the northern part of Poland. The results obtained by the passive sampling technique were compared to those obtained by dynamic sampling. Attempts were also made to identify indoor sources of pollution and assess the effect of the infiltration of outdoor pollutants on indoor air quality.
引用
收藏
页码:492 / 504
页数:13
相关论文
共 22 条
[1]  
*DECR MIN HLTH SOC, 1996, MAX ALL CONC POLL EM
[2]  
Finnish Society of Indoor Air Quality and Climate (FiSIAQ), 1995, CLASS IND CLIM CONST CLASS IND CLIM CONST
[3]   Aromatic hydrocarbons in the atmospheric environment: Part I. Indoor versus outdoor sources, the influence of traffic [J].
Ilgen, E ;
Karfich, N ;
Levsen, K ;
Angerer, J ;
Schneider, P ;
Heinrich, J ;
Wichmann, HE ;
Dunemann, L ;
Begerow, J .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (07) :1235-1252
[4]   Comparison of outdoor and indoor mobile source-related volatile organic compounds between low- and high-floor apartments [J].
Jo, WK ;
Kim, KY ;
Park, KH ;
Kim, YK ;
Lee, HW ;
Park, JK .
ENVIRONMENTAL RESEARCH, 2003, 92 (02) :166-171
[5]   Indoor air quality and health [J].
Jones, AP .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (28) :4535-4564
[6]  
Kozdron-Zabiegala B, 1995, INDOOR ENVIRON, V4, P189
[7]  
MOLHAVE L, 1992, INDOOR AIR, V27, P65
[8]   Passive sampling and/or extraction techniques in environmental analysis: a review [J].
Namiesnik, J ;
Zabiegala, B ;
Kot-Wasik, A ;
Partyka, M ;
Wasik, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (02) :279-301
[9]   Measuring strategies and monitoring of the indoor environment [J].
Schneider, T .
JOURNAL OF ENVIRONMENTAL MONITORING, 1999, 1 (05) :427-434
[10]  
Seifert B., 1999, Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz, P270, DOI [10.1007/978-3-662-38283-7_45, DOI 10.1007/978-3-662-38283-7_45]