Quantitative determination of folic acid in multivitamin/multielement tablets using liquid chromatography/tandem mass spectrometry

被引:98
|
作者
Nelson, Bryant C. [1 ]
Sharpless, Katherine E. [1 ]
Sander, Lane C. [1 ]
机构
[1] Natl Inst Stand & Technol, Div Analyt Chem, Gaithersburg, MD 20899 USA
基金
美国国家卫生研究院;
关键词
dietary supplements; folic acid; fortification; liquid chromatography; multivitamin/multielement; standard reference material; tandem mass spectrometry;
D O I
10.1016/j.chroma.2006.09.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two different isotope-dilution liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods for the quantitative determination of folic acid (FA) in multivitamin/multielement tablets are reported. These methods represent distinct improvements in terms of speed and specificity over most existing microbiological and chromatographic methods for the determination of FA in dietary supplements. The first method utilizes an aqueous/organic-based extraction solvent combined with positive-ion mode LC/MS/MS detection of protonated [M + H](+) FA molecules and the second method utilizes a pure aqueous-based extraction solvent combined with negative-ion mode LC/MS/MS detection of deprotonated [M - H](-) FA molecules. The LC/MS/MS methods exhibit comparable linear dynamic ranges ( :3 orders of magnitude), limits of detection (0.02ng on-column) and limits of quantification (0.06ng on-column) for FA. Two methods employing different extraction and different MS detection modes were developed to allow method cross-validation. Successful validation of each measurement procedure supports the use of either method for the certification of FA levels in dietary supplements. The accuracy and precision of each measurement procedure were evaluated by applying each method to the quantitative determination of FA in a NIST standard reference material (NIST SRM 3280 multivitamin/multielement tablets). The FA measurement accuracy for both methods was >= 95% (based on the manufacturer's assessment of the FA level in SRM 3280) with corresponding measurement precision values (% RSD) of approximately 1%. Published by Elsevier B.V.
引用
收藏
页码:203 / 211
页数:9
相关论文
共 50 条
  • [1] Rapid quantitation of ascorbic and folic acids in SRM 3280 multivitamin/multielement tablets using flow-injection tandem mass spectrometry
    Bhandari, Deepak
    Kertesz, Vilmos
    Van Berkel, Gary J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (01) : 163 - 168
  • [2] Quantitative Determination of Anastrozole by Liquid Chromatography–Tandem Mass Spectrometry
    I. I. Miroshnichenko
    N. I. Yurchenko
    A. I. Platova
    Pharmaceutical Chemistry Journal, 2013, 47 : 231 - 234
  • [3] Quantitative determination of perfluorooctanoic acid in serum and plasma by liquid chromatography tandem mass spectrometry
    Flaherty, JM
    Connolly, PD
    Decker, ER
    Kennedy, SM
    Ellefson, ME
    Reagen, WK
    Szostek, B
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (02): : 329 - 338
  • [4] Determination of iodoacetic acid using liquid chromatography/electrospray tandem mass spectrometry
    Lau, Benjamin P. -Y.
    Becalski, Adam
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (12) : 1787 - 1791
  • [5] Quantitative determination of ochratoxin A by liquid chromatography/electrospray tandem mass spectrometry
    Lau, BPY
    Scott, PM
    Lewis, DA
    Kanhere, SR
    JOURNAL OF MASS SPECTROMETRY, 2000, 35 (01): : 23 - 32
  • [6] Quantitative determination of methionine sulfoximine by liquid chromatography tandem mass spectrometry
    Gilbraith, William
    Gamagedara, Sanjeewa
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [7] Quantitative Determination of Anastrozole by Liquid Chromatography-Tandem Mass Spectrometry
    Miroshnichenko, I. I.
    Yurchenko, N. I.
    Platova, A. I.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2013, 47 (04) : 231 - 234
  • [8] Contents of selected B vitamins in NIST SRM 3280 multivitamin/multielement tablets by liquid chromatography isotope dilution mass spectrometry
    Pei Chen
    Mustafa Ozcan
    Wayne R. Wolf
    Analytical and Bioanalytical Chemistry, 2007, 389 : 343 - 347
  • [9] Contents of selected B vitamins in NIST SRM 3280 multivitamin/multielement tablets by liquid chromatography isotope dilution mass spectrometry
    Chen, Pei
    Ozcan, Mustafa
    Wolf, Wayne R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (01) : 343 - 347