Vasomotor Response to Nitroglycerine Over 5 Years Follow-Up After Everolimus-Eluting Bioresorbable Scaffold Implantation

被引:19
作者
Dudek, Dariusz [1 ]
Rzeszutko, Lukasz [2 ]
Onuma, Yoshinobu [3 ]
Sotomi, Yohei [4 ]
Depukat, Rafal [2 ]
Veldhof, Susan [5 ]
Ediebah, Divine [5 ]
Staehr, Peter [6 ]
Zasada, Wojciech [7 ]
Malinowski, Krzysztof P. [8 ]
Kaluza, Grzegorz L. [9 ]
Serruys, Patrick W. [10 ]
机构
[1] Jagiellonian Univ, Inst Cardiol, Kopernika 17th Str, PL-31501 Krakow, Poland
[2] Univ Hosp, Krakow, Poland
[3] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Amsterdam, Netherlands
[5] Abbott Vasc, Diegem, Belgium
[6] Abbott Vasc, Santa Clara, CA USA
[7] Krakow Cardiovasc Res Inst, Krakow, Poland
[8] Jagiellonian Univ, Coll Med, Krakow, Poland
[9] Cardiovasc Res Fdn, Orangeburg, NY USA
[10] Imperial Coll, Natl Heart & Lung Inst, Int Ctr Circulatory Hlth, London, England
关键词
ABSORB; bioresorbable scaffold; vasomotion; TERM ENDOTHELIAL DYSFUNCTION; STENOTIC CORONARY-ARTERIES; MULTI-IMAGING MODALITY; VASCULAR SCAFFOLD; BALLOON ANGIOPLASTY; STENT; 2ND-GENERATION; OUTCOMES; SYSTEM; VASOCONSTRICTION;
D O I
10.1016/j.jcin.2016.12.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study investigated the vasomotor response to nitroglycerine (NTG) up to 5 years after ABSORB implantation. BACKGROUND There are no data regarding long-term vasomotor response after everolimus-eluting bioresorbable vascular scaffold ABSORB implantation. METHODS We performed quantitative coronary angiography of the scaffolded and proximal and distal adjacent segments of patients from ABSORB Cohort B study before and after 200 mg of intracoronary NTG at 2, 3, and 5 years of follow-up. The mean changes of maximal and mean lumen diameters in the scaffolded and adjacent segments were calculated. RESULTS The mean in-scaffold lumen diameter change in response to NTG showed a trend to increase over time with absolute values of 0.03 +/- 0.09 mm, 0.05 +/- 0.12 mm, and 0.07 +/- 0.08 mm at 2, 3, and 5 years, respectively (p = 0.40). The maximal in-scaffold lumen diameter change significantly increased with values of 0.03 +/- 0.14 mm, 0.06 +/- 0.16 mm, and 0.11 +/- 0.1 mm at 2, 3, and 5 years, respectively (p = 0.03). The normalized mean lumen diameter change after NTG in the scaffold relative to the adjacent segments was 51.9 +/- 54.8% at 5 years of follow-up (p = 0.60). CONCLUSIONS Although there was a numerical increase of the vasomotor response to NTG after ABSORB implantation measured by quantitative coronary angiography with mean lumen diameter, the change was not statistically significant. However, the maximal lumen diameter changes increased over time from 2 to 5 years and attained statistical significance. The vasomotor response to NTG after ABSORB implantation moderately trended to increase, which is consistent with the progressive degradation and bioresorption of the scaffold, but the degree of vasomotor response remained lower in comparison with adjacent segments. (C) 2017 by the American College of Cardiology Foundation.
引用
收藏
页码:786 / 795
页数:10
相关论文
共 23 条
[1]   Endothelial-dependent vasomotion in a coronary segment treated by ABSORB everolimus-eluting bioresorbable vascular scaffold system is related to plaque composition at the time of bioresorption of the polymer: indirect finding of vascular reparative therapy? [J].
Brugaletta, Salvatore ;
Heo, Jung Ho ;
Garcia-Garcia, Hector M. ;
Farooq, Vasim ;
van Geuns, Robert Jan ;
de Bruyne, Bernard ;
Dudek, Dariusz ;
Smits, Pieter C. ;
Koolen, Jacques ;
McClean, Dougal ;
Dorange, Cecile ;
Veldhof, Susan ;
Rapoza, Richard ;
Onuma, Yoshinobu ;
Bruining, Nico ;
Ormiston, John A. ;
Serruys, Patrick W. .
EUROPEAN HEART JOURNAL, 2012, 33 (11) :1325-1333
[2]   Monitoring In Vivo Absorption of a Drug-Eluting Bioabsorbable Stent With Intravascular Ultrasound-Derived Parameters A Feasibility Study [J].
Bruining, Nico ;
de Winter, Sebastiaan ;
Roelandt, Jos R. T. C. ;
Regar, Evelyn ;
Heller, Iddo ;
van Domburg, Ron T. ;
Hamers, Ronald ;
Onuma, Yoshinobu ;
Dudek, Darius ;
Webster, Mark W. I. ;
Thuesen, Leif ;
Ormiston, John A. ;
Cheong, Wai-Fung ;
Miguel-Hebert, Karine ;
Veldhof, Susan ;
Serruys, Patrick W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (04) :449-456
[3]  
Camm A.J., 2009, The ESC textbook of cardiovascular medicine
[4]   Long-term endothelial dysfunction after coronary artery stenting [J].
Caramori, PRA ;
Lima, VC ;
Seidelin, PH ;
Newton, GE ;
Parker, JD ;
Adelman, AG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (06) :1675-1679
[5]   Anti-ischemic potential of drugs related to the renin-angiotensin system [J].
Ertl, G ;
Hu, K .
JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 2001, 37 :S11-S20
[6]   VASOCONSTRICTION OF STENOTIC CORONARY-ARTERIES DURING DYNAMIC EXERCISE IN PATIENTS WITH CLASSIC ANGINA-PECTORIS - REVERSIBILITY BY NITROGLYCERIN [J].
GAGE, JE ;
HESS, OM ;
MURAKAMI, T ;
RITTER, M ;
GRIMM, J ;
KRAYENBUEHL, HP .
CIRCULATION, 1986, 73 (05) :865-876
[7]   Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation [J].
Hofma, SH ;
van der Giessen, WJ ;
van Dalen, BM ;
Lemos, PA ;
McFadden, EP ;
Sianos, G ;
Ligthart, JMR ;
van Essen, D ;
de Feyter, PJ ;
Serruys, PW .
EUROPEAN HEART JOURNAL, 2006, 27 (02) :166-170
[8]   Alpha-adrenoceptor blockade prevents exercise-induced vasoconstriction of stenotic coronary arteries [J].
Julius, BK ;
Vassalli, G ;
Mandinov, L ;
Hess, OM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) :1499-1505
[9]  
Oberhauser James P, 2009, EuroIntervention, V5 Suppl F, pF15, DOI 10.4244/EIJV5IFA3
[10]   Intracoronary Optical Coherence Tomography and Histology at 1 Month and 2, 3, and 4 Years After Implantation of Everolimus-Eluting Bioresorbable Vascular Scaffolds in a Porcine Coronary Artery Model An Attempt to Decipher the Human Optical Coherence Tomography Images in the ABSORB Trial [J].
Onuma, Yoshinobu ;
Serruys, Patrick W. ;
Perkins, Laura E. L. ;
Okamura, Takayuki ;
Gonzalo, Nieves ;
Garcia-Garcia, Hector M. ;
Regar, Evelyn ;
Kamberi, Marika ;
Powers, Jennifer C. ;
Rapoza, Richard ;
van Beusekom, Heleen ;
van der Giessen, Willem ;
Virmani, Renu .
CIRCULATION, 2010, 122 (22) :2288-2300