Effect of Scour on the Natural Frequency Responses of Bridge Piers: Development of a Scour Depth Sensor

被引:15
作者
Boujia, Nissrine [1 ]
Schmidt, Franziska [1 ]
Chevalier, Christophe [1 ]
Siegert, Dominique [1 ]
van Bang, Damien Pham [2 ]
机构
[1] Univ Paris Est, Ifsttar, F-77420 Champs Sur Marne, France
[2] INRS, Ctr Eau Terre Environm, Quebec City, PQ G1K 9A9, Canada
关键词
bridge scour; vibration; soil-structure interaction; equivalent cantilever; monitoring;
D O I
10.3390/infrastructures4020021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Local scour is the removal of soil around bridge foundations under the erosive action of flowing water. This hydraulic risk has raised awareness of the need for developing continuous monitoring techniques to estimate scour depth around bridge piers and abutments. One of the emerging techniques is based on monitoring the vibration frequency of either bridge piers or a driven sensor in the riverbed. The sensor proposed in this study falls into the second category. Some unresolved issues are investigated: the effect of the geometry and material of the sensor, the effect of the embedded length and the effect of soil type. To this end, extensive laboratory tests are performed using rods of different materials, with various geometries and lengths. These tests are conducted in both dry sand and a soft clayey soil. Since the sensor will be placed in the riverbed, it is crucial to evaluate the effect of immersed conditions on its response. A numerical 3D finite-element model was developed and compared against experimental data. This model was then used to compute the 'wet' frequencies of the sensor. Finally, based on both the experimental and numerical results, an equivalent cantilever model is proposed to correlate the variation of the frequency of the sensor to the scour depth.
引用
收藏
页数:17
相关论文
共 34 条
[1]   Ground-penetrating radar: A tool for monitoring bridge scour [J].
Anderson, Neil L. ;
Ismael, Ahmed M. ;
Thitimakorn, Thanop .
ENVIRONMENTAL & ENGINEERING GEOSCIENCE, 2007, 13 (01) :1-10
[2]  
[Anonymous], 2009, FLUID MECH-SOV RES
[3]  
[Anonymous], 1997, SOIL MECH FOUND ENG+, DOI DOI 10.1007/S11204-010-9072-X
[4]  
Baguelin F., 1978, PRESSUREMETER FDN EN
[5]   Critical insights for advanced bridge scour detection using the natural frequency [J].
Bao, Ting ;
Swartz, R. Andrew ;
Vitton, Stanley ;
Sun, Ye ;
Zhang, Chad ;
Liu, Zhen .
JOURNAL OF SOUND AND VIBRATION, 2017, 386 :116-133
[6]   Flood scour monitoring system using fiber Bragg grating sensors [J].
Bin Lin, Yung ;
Lai, Jihn Sung ;
Chang, Kuo Chun ;
Li, Lu Sheng .
SMART MATERIALS AND STRUCTURES, 2006, 15 (06) :1950-1959
[7]   Modelling of a bridge pier subjected to scour [J].
Boujia, N. ;
Schmidt, F. ;
Siegert, D. ;
Van Bang, D. Pham ;
Chevalier, C. .
X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 :2925-2930
[8]  
Breusers H.N. C., 1991, Scouring, hydraulic structures design manual
[9]  
Briaud J-L., 2011, Technical Report
[10]  
Brunner G.W., 2010, HEC RAS RIVER ANAL S, V609