Asphericity of the anterior human cornea with different corneal diameters

被引:54
作者
Gonzalez-Meijome, Jose Manuel
Villa-Collar, Cesar
Montes-Mico, Robert
Gomes, Antonio
机构
[1] Univ Minho, Dept Phys Optometry, Sch Sci, P-4710057 Braga, Portugal
[2] Clin Oftalmol Novovis, Madrid, Spain
[3] Univ Valencia, Dept Opt, Valencia, Spain
关键词
D O I
10.1016/j.jcrs.2006.11.004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To measure the anterior corneal asphericity (Q) with different corneal diameters. SETTING: Department of Physics (Optometry), University of Minho, Braga, Portugal. METHODS: Thirty-six eyes of 36 patients were evaluated using a videokeratoscope, and the Q-values were recorded. Topographic data were also analyzed using Vol-CT 6.89 software (Sarver & Associates, Inc) to obtain the Q-values with different corneal diameters (3.0 mm, 4.0 mm, 5.0 mm, 6.0 mm, and 7.0 mm). Variable Q models of corneal sagittal height were compared against models assuming constant Q-values obtained with the Medmont E300 videokeratoscope (Medmont Pty. Ltd.) and a standard Q model of -0.26. RESULTS: The peripheral rate of change in corneal Q with different corneal diameters increased as corneal astigmatism increased. As a result, differences in the sagittal height between the constant model and variable model were evident beyond the central 3.0 mm area. There were significant differences between low and high astigmatic corneas in Q-values measured by the Medmont along the flattest meridian (P =.004) and Q-values obtained with Vol-CT software with a 7.0 mm corneal diameter (P =.026). CONCLUSIONS: There were differences in sagittal corneal height calculations considering constant or variable models of Q. Concern arises when surgical interventions depend on corneal Q-values to predict the outcomes. Surgeons should be aware which procedure is behind Q computing by different corneal topographers and that a constant Q-value cannot reflect the actual shape of the cornea as significant departures from the actual sagittal height can arise depending on which Q-value is assumed.
引用
收藏
页码:465 / 473
页数:9
相关论文
共 38 条
[1]   Wavefront-guided versus standard LASIK enhancement for residual refractive errors [J].
Alió, JL ;
Montés-Mico, R .
OPHTHALMOLOGY, 2006, 113 (02) :191-197
[2]   Differences between real and predicted corneal shapes after aspherical corneal ablation [J].
Anera, RG ;
Villa, C ;
Jiménez, JR ;
Gutiérrez, R ;
del Barco, LJ .
APPLIED OPTICS, 2005, 44 (21) :4528-4532
[3]   Changes in corneal asphericity after laser in situ keratomileusis [J].
Anera, RG ;
Jiménez, JR ;
del Barco, LJ ;
Bermúdez, J ;
Hita, E .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04) :762-768
[4]   Changes in corneal asphericity after laser refractive surgery, including reflection losses and nonnormal incidence upon the anterior cornea [J].
Anera, RG ;
Jiménez, JR ;
del Barco, LJ ;
Hita, E .
OPTICS LETTERS, 2003, 28 (06) :417-419
[5]  
Applegate RA, 2000, J REFRACT SURG, V16, P507
[6]   Evaluation of relationships among refractive and topographic parameters [J].
Budak, K ;
Khater, TT ;
Friedman, NJ ;
Holladay, JT ;
Koch, DD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (06) :814-820
[7]  
Bufidis Theodore, 1998, CLAO Journal, V24, P206
[8]   Automated keratoconus detection using the EyeSys videokeratoscope [J].
Chastang, PJ ;
Borderie, VM ;
Carvajal-Gonzalez, S ;
Rostène, W ;
Larohe, L .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (05) :675-683
[9]   CORNEAL ECCENTRICITY AS A TOOL FOR THE DIAGNOSIS OF KERATOCONUS [J].
DAO, CL ;
KOK, JHC ;
BRINKMAN, CJJ ;
VANMIL, CJ .
CORNEA, 1994, 13 (04) :339-344
[10]   Corneal asphericity and apical curvature in children: A cross-sectional and longitudinal evaluation [J].
Davis, WR ;
Raasch, TW ;
Mitchell, GL ;
Mutti, DO ;
Zadnik, K .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (06) :1899-1906