Dynamic Equivalent Model of Wind Power Plant Using Parameter Identification

被引:35
作者
Kim, Dong-Eok [1 ]
El-Sharkawi, Mohamed A. [2 ]
机构
[1] Korea Elect Power Corp Res Inst, Daejeon 34056, South Korea
[2] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
关键词
Dynamic equivalent; induction generator; wind energy; STABILITY;
D O I
10.1109/TEC.2015.2470562
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The dynamic performance of wind power plants is difficult to model because of the large number of turbines that operate stochastically, with little information exchanged between the wind power plants and the serving utilities. In this study, we develop a linear dynamic equivalent model for large-scale wind power plants on the basis of data obtained at the point of interconnection in simulation. The modeling technique is based on adaptive parameter estimation of an equivalent model representing the dynamic performance of the plant. The developed model is tested against a large-scale plant model to confirm the effectiveness of the proposed technique.
引用
收藏
页码:37 / 45
页数:9
相关论文
共 33 条
  • [21] CHOICE OF MODEL AND TOPOLOGY FOR EXTERNAL EQUIVALENT SYSTEMS
    ELSHARKAWI, MA
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (12): : 3761 - 3768
  • [22] Fajardo-R L.A., 2009, Int. Conf. on Elect. Machines and Systems (ICEMS 2009), P1
  • [23] Reduced model of DFIGs wind farms using aggregation of wind turbines and equivalent wind
    Fernandez, L. M.
    Garcia, C. A.
    Saenz, J. R.
    Jurado, F.
    [J]. CIRCUITS AND SYSTEMS FOR SIGNAL PROCESSING , INFORMATION AND COMMUNICATION TECHNOLOGIES, AND POWER SOURCES AND SYSTEMS, VOL 1 AND 2, PROCEEDINGS, 2006, : 881 - 884
  • [24] Fitzgerald A.E., 1961, ELECT MACHINERY
  • [25] A Type-4 Wind Power Plant Equivalent Model for the Analysis of Electromagnetic Transients in Power Systems
    Hussein, Dalia N.
    Matar, Mahmoud
    Iravani, Reza
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (03) : 3096 - 3104
  • [26] Ju P., 2009, P IEEE INT C SUST PO, V8, P1
  • [27] Kanellos F., 2003, IEEE POW TECH C BOL
  • [28] Doubly fed induction generator model for transient stability analysis
    Ledesma, P
    Usaola, J
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) : 388 - 397
  • [29] Modeling of the wind turbine with a doubly fed induction generator for grid integration studies
    Lei, YZ
    Mullane, A
    Lightbody, G
    Yacamini, R
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (01) : 257 - 264
  • [30] Meng Z. J., 2010, P 4 INT C IEEE BIOIN, P1