A non-water-cooled heat flux measurement system under concentrated solar radiation conditions

被引:31
作者
Ballestrin, J [1 ]
机构
[1] Cent Receiver Technol, Plataforma Solar Almeria, Tabernas 4200, Almeria, Spain
关键词
D O I
10.1016/S0038-092X(02)00046-4
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a brief description of a direct heat flux measurement system to measure the concentrated solar power delivered by a heliostat field onto the flat aperture of solar central receiver prototypes. The main advantages of this device are the low measurement uncertainty and the non-requirement of water-cooling. This system has been designed, mounted and used successfully on top of the SSPS-CRS tower at the Plataforma Solar de Almeria (PSA). The concentrated solar power and the spatial heat flux distribution, onto the aperture of a volumetric receiver prototype under evaluation, have been determined by the above-mentioned system. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:159 / 168
页数:10
相关论文
共 12 条
[1]  
Bevington P., 2002, Data Reduction and Error Analysis for the Physical Sciences, V3rd ed.
[2]  
Carasso M., 1990, PERFORMANCE EVALUATI, V3
[3]  
Diessner F, 1981, OPERATION MANUAL MEA
[4]  
GARCIA G, 1988, R1588GG
[5]   EXPERIMENTAL PERFORMANCE OF A HEAT-FLUX MICROSENSOR [J].
HAGER, JM ;
SIMMONS, S ;
SMITH, D ;
ONISHI, S ;
LANGLEY, LW ;
DILLER, TE .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1991, 113 (02) :246-250
[6]  
HOFFSCHMIDT B, 1998, IEA SOL PACES SOL TE
[7]   Assessment of uncertainty in solar collector modeling and testing [J].
Mathioulakis, E ;
Voropoulos, K ;
Belessiotis, V .
SOLAR ENERGY, 1999, 66 (05) :337-347
[8]  
NEUMANN A, 1996, PROCEDURES FLUX MEAS
[9]  
PEABODY HL, 1997, THESIS FACULTY VIRGI
[10]  
*PLAT SOL ALM PSA, 1996, ANN TECHN REP CIEMAT