Treatment of femoral neck fractures: sliding hip screw or cannulated screws? A meta-analysis

被引:43
|
作者
Xia, Yutong [1 ]
Zhang, Wendong [2 ]
Zhang, Zhen [1 ]
Wang, Jingcheng [1 ,2 ]
Yan, Lianqi [2 ,3 ]
机构
[1] Dalian Med Univ, Dalian 116044, Liaoning, Peoples R China
[2] Northern Jiangsu Peoples Hosp, Dept Orthoped, Yangzhou 225001, Jiangsu, Peoples R China
[3] Cent South Univ, Xiangya Hosp 2, Changsha 410012, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Femoral neck fracture; Sliding hip screw; Cannulated compression screw; Internal fixation; Meta-analysis;
D O I
10.1186/s13018-020-02189-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeFemoral neck fractures are still unsolved problems nowadays; sliding hip screw (SHS) and cannulated compression screw (CCS) are the most commonly used devices. We evaluated the clinical outcomes and complications in the treatment of femoral neck fractures between SHS and CCS in this meta-analysis to find which is better.MethodsWe searched PubMed, Embase, Cochrane library up to 24 August 2020 and retrieved any studies comparing sliding hip screw and cannulated compression screw in treatment of femoral neck fractures; the main outcomes and complications were extracted from the studies which were included.ResultsNine studies involving 1662 patients (828 patients in the SHS group and 834 patients in the CCS group) were included in this study. SHS had higher rate of avascular necrosis (RR = 1.30, 95% CI 1.08-1.56, p = 0.005), and CCS had higher rate of implant removal (RR = 0.63, 95% CI 0.43-0.93, p = 0.02). No significant statistical difference in non-union, implant failure, infection, replacement, mortality, orthopedic complications, non-orthopedic complications, and total revision between SHS and CCS group.ConclusionBoth devices have their pros and cons; SHS had a higher rate of avascular necrosis, and CCS had a higher rate of implant removal rate. No significant statistical difference in non-union, implant failure, infection, replacement, mortality, orthopedic complications, non-orthopedic complications, and total revision between SHS and CCS group.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Treatment of femoral neck fractures: sliding hip screw or cannulated screws? A meta-analysis
    Yutong Xia
    Wendong Zhang
    Zhen Zhang
    Jingcheng Wang
    Lianqi Yan
    Journal of Orthopaedic Surgery and Research, 16
  • [2] Multiple cannulated screws vs. dynamic hip screws for femoral neck fractures A meta-analysis
    Zhang, Lei Lei
    Zhang, Ying
    Ma, Xianghao
    Liu, Youwen
    ORTHOPADE, 2017, 46 (11): : 954 - 962
  • [3] Dynamic hip screws versus cannulated screws for femoral neck fractures: a systematic review and meta-analysis
    Lang Li
    Xue Zhao
    Xiaodong Yang
    Xueyang Tang
    Ming Liu
    Journal of Orthopaedic Surgery and Research, 15
  • [4] Dynamic hip screws versus cannulated screws for femoral neck fractures: a systematic review and meta-analysis
    Li, Lang
    Zhao, Xue
    Yang, Xiaodong
    Tang, Xueyang
    Liu, Ming
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [5] Sliding hip screws versus cancellous screws for femoral neck fractures: a systematic review and meta-analysis
    Shehata, Mohamed S. A.
    Aboelnas, Mohamed M.
    Abdulkarim, Ali N.
    Abdallah, Ahmed R.
    Ahmed, Hussien
    Holton, James
    Consigliere, Paolo
    Narvani, Ali A.
    Sallam, Asser A.
    Wimhurst, James A.
    Imam, Mohamed A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (07): : 1383 - 1393
  • [6] Sliding hip screws versus cancellous screws for femoral neck fractures: a systematic review and meta-analysis
    Mohamed S. A. Shehata
    Mohamed M. Aboelnas
    Ali N. Abdulkarim
    Ahmed R. Abdallah
    Hussien Ahmed
    James Holton
    Paolo Consigliere
    Ali A. Narvani
    Asser A. Sallam
    James A. Wimhurst
    Mohamed A. Imam
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 1383 - 1393
  • [7] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiang, Jiabao
    Chen, Jialei
    Xing, Fei
    Liu, Hao
    Xiang, Zhou
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [8] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiabao Jiang
    Jialei Chen
    Fei Xing
    Hao Liu
    Zhou Xiang
    BMC Musculoskeletal Disorders, 24
  • [9] The Targon Femoral Neck hip screw versus cannulated screws for internal fixation of intracapsular fractures of the hip
    Griffin, X. L.
    Parsons, N.
    Achten, J.
    Costa, M. L.
    BONE & JOINT JOURNAL, 2014, 96B (05): : 652 - 657
  • [10] Comparison Between Femoral Neck Systems and Cannulated Cancellous Screws in Treating Femoral Neck Fractures: A Meta-Analysis
    Tian, Peng
    Kuang, Lan
    Li, Zhi-jun
    Xu, Gui-jun
    Fu, Xin
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2022, 13