Voltammetric characterisation of silicon-based microelectrode arrays and their application to mercury-free stripping voltammetry of copper ions

被引:76
作者
Berduque, Alfonso [1 ]
Lanyon, Yvonne H. [1 ]
Beni, Valerio [1 ]
Herzog, Gregoire [1 ]
Watson, Yvonne E. [1 ]
Rodgers, Kenneth [1 ]
Stam, Frank [1 ]
Alderman, John [1 ]
Arrigan, Damien W. M. [1 ]
机构
[1] Univ Coll Cork, Tyndall Natl Inst, Cork, Ireland
关键词
microelectrode array; voltammetry; micro-square and micro-band electrodes; stripping voltammetry; metal ion detection;
D O I
10.1016/j.talanta.2006.05.090
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the electrochemical characterisation of a range of gold and platinum microelectrode arrays (MEAs) fabricated by standard photolithographic methods. The inter-electrode spacing, geometry, numbers and dimensions of the electrodes in the arrays were found to influence the voltammetric behaviours obtained. Excellent correlation was found between experimental data and theoretical predictions employing published models of microelectrode behaviour. Gold MEAs were evaluated for their applicability to copper determination in a soil extract sample, where agreement was found between the standard analytical method and a method based on underpotential deposition-anodic stripping voltammetry (UPD-ASV) at the MEAs, offering a mercury-free alternative for copper sensing. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1022 / 1030
页数:9
相关论文
共 46 条
  • [31] 2-Z
  • [32] Monk P., 2001, FUNDAMENTALS ELECTRO
  • [33] IMPROVEMENT OF ANALYTICAL MEASUREMENTS WITHIN THE BCR-PROGRAM - SINGLE AND SEQUENTIAL EXTRACTION PROCEDURES APPLIED TO SOIL AND SEDIMENT ANALYSIS
    QUEVAUVILLER, P
    URE, A
    MUNTAU, H
    GRIEPINK, B
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1993, 51 (1-4) : 129 - 134
  • [34] Microfabricated electrochemical analysis system for heavy metal detection
    Reay, RJ
    Flannery, AF
    Storment, CW
    Kounaves, SP
    Kovacs, GTA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) : 450 - 455
  • [35] Multi-element heavy metal ion sensors for aqueous solutions
    Saban, SB
    Darling, RB
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 61 (1-3) : 128 - 137
  • [36] Optimization of the geometry and porosity of microelectrode arrays for sensor design
    Sandison, ME
    Anicet, N
    Glidle, A
    Cooper, JM
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (22) : 5717 - 5725
  • [37] Passivation and corrosion of microelectrode arrays
    Schmitt, G
    Schultze, JW
    Fassbender, F
    Buss, G
    Lüth, H
    Schöning, MJ
    [J]. ELECTROCHIMICA ACTA, 1999, 44 (21-22) : 3865 - 3883
  • [38] Microelectrodes.: Definitions, characterization, and applications (Technical Report)
    Stulík, K
    Amatore, C
    Holub, K
    Marecek, V
    Kutner, W
    [J]. PURE AND APPLIED CHEMISTRY, 2000, 72 (08) : 1483 - 1492
  • [39] Highly sensitive heavy metal analysis on platinum- and gold-ultramicroelectrode arrays
    Uhlig, A
    Schnakenberg, U
    Hintsche, R
    [J]. ELECTROANALYSIS, 1997, 9 (02) : 125 - 129
  • [40] Real-time electrochemical monitoring: Toward green analytical chemistry
    Wang, J
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 2002, 35 (09) : 811 - 816