Voltammetric characterisation of silicon-based microelectrode arrays and their application to mercury-free stripping voltammetry of copper ions

被引:76
作者
Berduque, Alfonso [1 ]
Lanyon, Yvonne H. [1 ]
Beni, Valerio [1 ]
Herzog, Gregoire [1 ]
Watson, Yvonne E. [1 ]
Rodgers, Kenneth [1 ]
Stam, Frank [1 ]
Alderman, John [1 ]
Arrigan, Damien W. M. [1 ]
机构
[1] Univ Coll Cork, Tyndall Natl Inst, Cork, Ireland
关键词
microelectrode array; voltammetry; micro-square and micro-band electrodes; stripping voltammetry; metal ion detection;
D O I
10.1016/j.talanta.2006.05.090
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the electrochemical characterisation of a range of gold and platinum microelectrode arrays (MEAs) fabricated by standard photolithographic methods. The inter-electrode spacing, geometry, numbers and dimensions of the electrodes in the arrays were found to influence the voltammetric behaviours obtained. Excellent correlation was found between experimental data and theoretical predictions employing published models of microelectrode behaviour. Gold MEAs were evaluated for their applicability to copper determination in a soil extract sample, where agreement was found between the standard analytical method and a method based on underpotential deposition-anodic stripping voltammetry (UPD-ASV) at the MEAs, offering a mercury-free alternative for copper sensing. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1022 / 1030
页数:9
相关论文
共 46 条
  • [1] DIFFUSIONAL MASS-TRANSPORT TO MICROBAND ELECTRODES OF PRACTICAL GEOMETRIES - A SIMULATION STUDY USING THE STRONGLY IMPLICIT PROCEDURE
    ALDEN, JA
    BOOTH, J
    COMPTON, RG
    DRYFE, RAW
    SANDERS, GHW
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 389 (1-2): : 45 - 54
  • [2] Amatore C., 1995, PHYS ELECTROCHEMISTR, P131
  • [3] THEORY OF ULTRAMICROELECTRODES
    AOKI, K
    [J]. ELECTROANALYSIS, 1993, 5 (08) : 627 - 639
  • [4] Bard A. J., 2001, Electrochemical Methods: Fundamentals and Applications, P168
  • [5] Mercury-plated iridium-based microelectrode arrays for trace metals detection by voltammetry: Optimum conditions and reliability
    Belmont, C
    Tercier, ML
    Buffle, J
    Fiaccabrino, GC
    KoudelkaHep, M
    [J]. ANALYTICA CHIMICA ACTA, 1996, 329 (03) : 203 - 214
  • [6] Development of a portable electroanalytical system for the stripping voltammetry of metals: Determination of copper in acetic acid soil extracts
    Beni, V
    Ogurtsov, VI
    Bakunin, NV
    Arrigan, DWM
    Hill, M
    [J]. ANALYTICA CHIMICA ACTA, 2005, 552 (1-2) : 190 - 200
  • [7] Voltammetric behaviour at gold electrodes immersed in the BCR sequential extraction scheme media - Application of underpotential deposition-stripping voltammetry to determination of copper in soil extracts
    Beni, V
    Newton, HV
    Arrigan, DWM
    Hill, M
    Lane, WA
    Mathewson, A
    [J]. ANALYTICA CHIMICA ACTA, 2004, 502 (02) : 195 - 206
  • [8] A COMPARISON OF THE CHRONOAMPEROMETRIC RESPONSE AT INLAID AND RECESSED DISK MICROELECTRODES
    BOND, AM
    LUSCOMBE, D
    OLDHAM, KB
    ZOSKI, CG
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 249 (1-2): : 1 - 14
  • [9] BOND AM, 1994, ANALYST, V119, P1
  • [10] Characteristics of nanoscopic Au band electrodes
    Caston, SL
    McCarley, RL
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 529 (02) : 124 - 134