Analysis of woody biomass utilization for heat, electricity, and CHP in a regional city of Japan

被引:26
作者
Furubayashi, Takaaki [1 ]
Nakata, Toshihiko [2 ]
机构
[1] Akita Univ, Grad Sch Engn Sci, 1-1 Tegata-Gakuenmachi, Akita 0108502, Japan
[2] Tohoku Univ, Grad Sch Engn, 6-6-11-815 Aramaki,Aoba-ku, Sendai, Miyagi 9808579, Japan
关键词
Woody biomass; Combined heat and power; Heat-only boiler; District heating system; Biomass utilization in Japan; RENEWABLE ENERGY; SOLAR-ENERGY; SYSTEMS; DESIGN; RESOURCES; REDUCTION;
D O I
10.1016/j.jclepro.2020.125665
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study analyzes a regional biomass energy system in Japan. Herein, based on local characteristics, such as the heat load and distribution, we compared the woody biomass used for heat, electricity, and combined heat and power (CHP) with or without a district heating system (DHS). In this study, target demands were selected from the actual residential and commercial sectors of Koriyama City in Fukushima Prefecture using two maps of heat density. A heat pipe network between each buildings was designed using Dijkstra's algorithm, and the amount of woody biomass used in each case was fixed such that it satisfied the heat demands of heat-only boilers. Therefore, there were no meshes with unit heat densities >4.2 TJ/ha. However, we found areas with the required heat densities and selected 90 buildings for the DHS. The case that both CHP and DHS were installed and the CHP operational model followed the heat demand (i.e., the "CHP follow" case) was the most effective to reduce CO2. When individual heat-only boilers were installed in buildings, the CO2 reduction was substantial; however, the capital costs associated with heat-only boilers were much higher than the those of the other scenarios. When a heat-only boiler and DHS were installed (i.e., the "Heat DHS" case), the CO2 reduction was competitive with the "CHP follow" scenario, however, total cost was more expensive. Furthermore, the cost of reducing CO2 would be larger than that of "CHP follow" case even if the CO2 emissions factor of grid electricity was less than half of its current value. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:12
相关论文
共 37 条
  • [1] Agency for Natural Resources and Energy, 2015, LONG TERM PROSP EN D
  • [2] Agency of National Resources and Energy, 2019, HDB HEAT SUPPLY BUSI
  • [3] Agency of National Resources and Energy, 2019, HDB EL POW IND
  • [4] Thermal energy storage materials and systems for solar energy applications
    Alva, Guruprasad
    Liu, Lingkun
    Huang, Xiang
    Fang, Guiyin
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 68 : 693 - 706
  • [5] On the performance of district heating systems in urban environment: an emergy approach
    Andric, I.
    Pina, A.
    Ferrao, P.
    Lacarriere, B.
    Le Corre, O.
    [J]. JOURNAL OF CLEANER PRODUCTION, 2017, 142 : 109 - 120
  • [6] Sustainable design of renewable energy supply chains integrated with district heating systems: A fuzzy optimization approach
    Balaman, Sebnem Yilmaz
    Selim, Hasan
    [J]. JOURNAL OF CLEANER PRODUCTION, 2016, 133 : 863 - 885
  • [7] Cost Assessment of a District Heating System in Northern Japan Using a Geographic Information-Based Mixed Integer Linear Programming Model
    Baldvinsson, Ivar
    Nakata, Toshihiko
    [J]. JOURNAL OF ENERGY ENGINEERING, 2017, 143 (03)
  • [8] District heating (DH) network design and operation toward a system-wide methodology for optimizing renewable energy solutions (SMORES) in Canada: A case study
    Dalla Rosa, A.
    Boulter, R.
    Church, K.
    Svendsen, S.
    [J]. ENERGY, 2012, 45 (01) : 960 - 974
  • [9] Dijkstra EW., 1959, Numer Math (Heidelb), V1, P271, DOI [DOI 10.1007/BF01386390, 10.1007/BF01386390]
  • [10] Proliferation of district heating using local energy resources through strategic building-stock management: A case study in Fukushima, Japan
    Dou, Yi
    Okuoka, Keijiro
    Fujii, Minoru
    Tanikawa, Hiroki
    Fujita, Tsuyoshi
    Togawa, Takuya
    Dong, Liang
    [J]. FRONTIERS IN ENERGY, 2018, 12 (03) : 411 - 425