Improvement of signal processing in Coriolis mass flowmeters for gas-liquid two-phase flow

被引:1
|
作者
Li, Chunhui [1 ]
Sun, Lijun [1 ]
Liu, Jiarong [1 ]
Zhang, Yang [1 ]
Li, Haiyang [2 ]
Wang, Huaxiang [1 ]
机构
[1] Tianjin Univ, Sch Elect & Informat Engn, Tianjin 300072, Peoples R China
[2] Shanghai Inst Measurement & Testing Technol, Shanghai 201203, Peoples R China
关键词
Coriolis mass flowmeter; Digital signal processing method; Two-phase flow condition; Quadrature demodulation; Sliding discrete time Fourier transform (SDTFT); Hilbert transform; TH814;
D O I
10.1631/FITEE.1900558
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
As an increasingly popular flow metering technology, Coriolis mass flowmeter exhibits high measurement accuracy under single-phase flow condition and is widely used in the industry. However, under complex flow conditions, such as two-phase flow, the measurement accuracy is greatly decreased due to various factors including improper signal processing methods. In this study, three digital signal processing methods-the quadrature demodulation (QD) method, Hilbert method, and sliding discrete time Fourier transform method-are analyzed for their applications in processing sensor signals and providing measurement results under gas-liquid two-phase flow condition. Based on the analysis, specific improvements are applied to each method to deal with the signals under two-phase flow condition. For simulation, sensor signals under single- and two-phase flow conditions are established using a random walk model. The phase difference tracking performances of these three methods are evaluated in the simulation. Based on the digital signal processor, a converter program is implemented on its evaluation board. The converter program is tested under single- and two-phase flow conditions. The improved signal processing methods are evaluated in terms of the measurement accuracy and complexity. The QD algorithm has the best performance under the single-phase flow condition. Under the two-phase flow condition, the QD algorithm performs a little better in terms of the indication error and repeatability than the improved Hilbert algorithm at 160, 250, and 420 kg/h flow points, whereas the Hilbert algorithm outperforms the QD algorithm at the 600 kg/h flow point.
引用
收藏
页码:272 / 286
页数:15
相关论文
共 50 条
  • [1] Signal Processing of Coriolis Mass Flowmeters under Gas-Liquid Two-Phase Flow Conditions
    Liu, Jiarong
    Sun, Lijun
    Wang, Huaxiang
    2018 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC): DISCOVERING NEW HORIZONS IN INSTRUMENTATION AND MEASUREMENT, 2018, : 1095 - 1100
  • [2] Gas-Liquid Two-Phase Flow Measurement Based on Coriolis Flowmeters and PSO-SVM
    Sun, Lijun
    Liu, Yue
    Tong, Jielin
    Chen, Shuiyuan
    Gao, Jingyu
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2022, 55 (10): : 1034 - 1044
  • [3] Gas-liquid Two-phase Flow Measurement Using Coriolis Flowmeters Incorporating Neural Networks
    Wang, Lijuan
    Liu, Jinyu
    Yan, Yong
    Wang, Xue
    Wang, Tao
    2016 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, 2016, : 747 - 751
  • [4] Mass flow measurement of gas-liquid two-phase CO2 in CCS transportation pipelines using Coriolis flowmeters
    Wang, Lijuan
    Yan, Yong
    Wang, Xue
    Wang, Tao
    Duan, Quansheng
    Zhang, Wenbiao
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2018, 68 : 269 - 275
  • [5] Complex signal processing for Coriolis mass flow metering in two-phase flow
    Li, Ming
    Henry, Manus
    FLOW MEASUREMENT AND INSTRUMENTATION, 2018, 64 : 104 - 115
  • [6] Signal Processing Methods for Coriolis Mass Flow Metering in Two-Phase Flow Conditions
    Li, Ming
    Henry, Manus
    PROCEEDINGS 2016 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2016, : 690 - 695
  • [7] A combination method for metering gas-liquid two-phase flows of low liquid loading applying ultrasonic and Coriolis flowmeters
    Xing, Lanchang
    Geng, Yanfeng
    Hua, Chenquan
    Zhu, Hao
    Rieder, Alfred
    Drahm, Wolfgang
    Bezdek, Michal
    FLOW MEASUREMENT AND INSTRUMENTATION, 2014, 37 : 135 - 143
  • [8] Mass Flow Measurement of Two-phase Carbon Dioxide Using Coriolis Flowmeters
    Wang, Lijuan
    Liu, Jinyu
    Yan, Yong
    Wang, Xue
    Wang, Tao
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 1299 - 1303
  • [9] Improvement of signal processing in Coriolis mass flowmeters for gas-liquid two-phase flow科里奥利质量流量计气液两相流信号处理的改进
    Chunhui Li
    Lijun Sun
    Jiarong Liu
    Yang Zhang
    Haiyang Li
    Huaxiang Wang
    Frontiers of Information Technology & Electronic Engineering, 2021, 22 : 272 - 286
  • [10] Two-phase flow experiments with Coriolis Mass Flow Metering using complex signal processing
    Li, Ming
    Henry, Manus
    Zhou, Feibiao
    Tombs, Michael
    FLOW MEASUREMENT AND INSTRUMENTATION, 2019, 69