Automatic large quantity landmark pairs detection in 4DCT lung images

被引:22
作者
Fu, Yabo [1 ]
Wu, Xue [1 ]
Thomas, Allan M. [1 ]
Li, Harold H. [1 ]
Yang, Deshan [1 ]
机构
[1] Washington Univ, Dept Radiat Oncol, St Louis, MO 63110 USA
基金
美国医疗保健研究与质量局;
关键词
Deformable image registration; medical image processing; ADAPTIVE RADIATION-THERAPY; EXPERIMENTAL VALIDATION; REGISTRATION; RADIOTHERAPY; ACCURACY; HEAD; REGULARIZATION; DEFORMATION; PROPAGATION; CT;
D O I
10.1002/mp.13726
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To automatically and precisely detect a large quantity of landmark pairs between two lung computed tomography (CT) images to support evaluation of deformable image registration (DIR). We expect that the generated landmark pairs will significantly augment the current lung CT benchmark datasets in both quantity and positional accuracy. Methods A large number of landmark pairs were detected within the lung between the end-exhalation (EE) and end-inhalation (EI) phases of the lung four-dimensional computed tomography (4DCT) datasets. Thousands of landmarks were detected by applying the Harris-Stephens corner detection algorithm on the probability maps of the lung vasculature tree. A parametric image registration method (pTVreg) was used to establish initial landmark correspondence by registering the images at EE and EI phases. A multi-stream pseudo-siamese (MSPS) network was then developed to further improve the landmark pair positional accuracy by directly predicting three-dimensional (3D) shifts to optimally align the landmarks in EE to their counterparts in EI. Positional accuracies of the detected landmark pairs were evaluated using both digital phantoms and publicly available landmark pairs. Results Dense sets of landmark pairs were detected for 10 4DCT lung datasets, with an average of 1886 landmark pairs per case. The mean and standard deviation of target registration error (TRE) were 0.47 +/- 0.45 mm with 98% of landmark pairs having a TRE smaller than 2 mm for 10 digital phantom cases. Tests using 300 manually labeled landmark pairs in 10 lung 4DCT benchmark datasets (DIRLAB) produced TRE results of 0.73 +/- 0.53 mm with 97% of landmark pairs having a TRE smaller than 2 mm. Conclusion A new method was developed to automatically and precisely detect a large quantity of landmark pairs between lung CT image pairs. The detected landmark pairs could be used as benchmark datasets for more accurate and informative quantitative evaluation of DIR algorithms.
引用
收藏
页码:4490 / 4501
页数:12
相关论文
共 58 条
[1]  
[Anonymous], 1988, ALVEY VISION C
[2]  
[Anonymous], 2017, CORR
[3]   Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task [J].
Brock, Kristy K. ;
Mutic, Sasa ;
McNutt, Todd R. ;
Li, Hua ;
Kessler, Marc L. .
MEDICAL PHYSICS, 2017, 44 (07) :E43-E76
[4]   Adaptive Radiotherapy of Head and Neck Cancer [J].
Castadot, Pierre ;
Lee, John A. ;
Geets, Xavier ;
Gregoire, Vincent .
SEMINARS IN RADIATION ONCOLOGY, 2010, 20 (02) :84-93
[5]   Assessment by a deformable registration method of the volumetric and positional changes of target volumes and organs at risk in pharyngo-laryngeal tumors treated with concomitant chemo-radiation [J].
Castadot, Pierre ;
Geets, Xavier ;
Lee, John Aldo ;
Christian, Nicolas ;
Gregoire, Vincent .
RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) :209-217
[6]   Quadratic penalty method for intensity-based deformable image registration and 4DCT lung motion recovery [J].
Castillo, Edward .
MEDICAL PHYSICS, 2019, 46 (05) :2194-2203
[7]   A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets [J].
Castillo, Richard ;
Castillo, Edward ;
Guerra, Rudy ;
Johnson, Valen E. ;
McPhail, Travis ;
Garg, Amit K. ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) :1849-1870
[8]   Biomechanical deformable image registration of longitudinal lung CT images using vessel information [J].
Cazoulat, Guillaume ;
Owen, Dawn ;
Matuszak, Martha M. ;
Balter, James M. ;
Brock, Kristy K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (13) :4826-4839
[9]   Auto-propagation of contours for adaptive prostate radiation therapy [J].
Chao, Ming ;
Xie, Yaoqin ;
Xing, Lei .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17) :4533-4542
[10]   4D dose-position verification in radiation therapy using the RADPOS system in a deformable lung phantom [J].
Cherpak, Amanda ;
Serban, Monica ;
Seuntjens, Jan ;
Cygler, Joanna E. .
MEDICAL PHYSICS, 2011, 38 (01) :179-187