Reduction of carry-over in column-switching HPLC/MS system with automated system washing procedure for highly sensitive direct analysis of donepezil in dog plasma

被引:27
作者
Asakawa, Yoshiki
Ozawa, Chinami
Osada, Katsunobu
Kaneko, Shoji
Asakawa, Naoki
机构
[1] Sunplanet Co Ltd, Gifu 5016024, Japan
[2] Eisai & Co Ltd, Analyt Res Labs, Gifu 5016195, Japan
[3] Eisai & Co Ltd, Drug Dev Technol, Tsukuba, Ibaraki 3002635, Japan
关键词
carry-over; pharmacokinetics; RAM; column-switching; donepezil; on-line sample pretreatment;
D O I
10.1016/j.jpba.2006.08.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To solve the problem of carry-over - a persistent chromatographic challenge for bioanalytical assays with highly sensitive detector such as a mass spectrometry (MS) - a new on-line sample pretreatment HPLC/MS system using a column-switching technique was established. This system was designed to reduce carry-over based on a hydrophobic interaction mechanism using a washing function (multi-mobile phase flow system), as well as to remove impurities on-line in a mobile phase for the pretreatment. As a result, a washing function in this system was enabled to reduce carry-over and to remove impurities in a mobile phase by automatic operation. Therefore, concentration levels of donepezil (DH) in dog plasma as low as 10 pg/mL could be determined using this on-line sample pretreatment HPLC/MS system. In addition, method validation results of specificity, linearity, accuracy, precision, lower limit of quantitation (LLOQ), and carry-over demonstrated that this on-line sample pretreatment HPLC/MS system was robust and valid as a practical assay of drugs and metabolites in the biological samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:683 / 690
页数:8
相关论文
共 23 条
[1]  
Dolan JW, 2001, LC GC N AM, V19, P1050
[2]  
Dolan JW, 2001, LC GC N AM, V19, P478
[3]  
Dolan JW, 2001, LC GC N AM, V19, P164
[4]  
Dolan JW, 2001, LC GC N AM, V19, P32
[5]   SHIELDED HYDROPHOBIC PHASE - A NEW CONCEPT FOR DIRECT INJECTION-ANALYSIS OF BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GISCH, DJ ;
HUNTER, BT ;
FEIBUSH, B .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 433 :264-268
[6]   INTERNAL SURFACE REVERSED-PHASE SILICA SUPPORTS FOR LIQUID-CHROMATOGRAPHY [J].
HAGESTAM, IH ;
PINKERTON, TC .
ANALYTICAL CHEMISTRY, 1985, 57 (08) :1757-1763
[7]   INTERNAL SURFACE REVERSED-PHASE SILICA SUPPORT PREPARED WITH CHYMOTRYPSIN [J].
HAGESTAM, IH ;
PINKERTON, TC .
JOURNAL OF CHROMATOGRAPHY, 1986, 351 (02) :239-248
[8]   SYNTHESIS OF MIXED-FUNCTIONAL-PHASE SILICA SUPPORTS FOR LIQUID-CHROMATOGRAPHY AND THEIR APPLICATIONS TO ASSAYS OF DRUGS IN SERUM [J].
HAGINAKA, J ;
WAKAI, J ;
YASUDA, H .
JOURNAL OF CHROMATOGRAPHY, 1990, 535 (1-2) :163-172
[9]   INTERNAL-SURFACE REVERSED-PHASE SILICA SUPPORT FOR DIRECT INJECTION DETERMINATION OF DRUGS IN BIOLOGICAL-FLUIDS BY LIQUID-CHROMATOGRAPHY [J].
HAGINAKA, J ;
YASUDA, N ;
WAKAI, J ;
MATSUNAGA, H ;
YASUDA, H ;
KIMURA, Y .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2445-2448
[10]   On-line pretreatment using methylcellulose-immobilized cation-exchange restricted access media for direct liquid chromatography/mass spectrometric determination of basic drugs in plasma [J].
Kawano, S ;
Takahashi, M ;
Hine, T ;
Yamamoto, E ;
Asakawa, N .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (19) :2827-2832