Accurate mass determination by multiple sprayers nano-electrospray mass spectrometry on a magnetic sector instrument

被引:0
作者
Takahashi, Y
Fujimaki, S
Kobayashi, T
Morita, T
Higuchi, T
机构
[1] JEOL Ltd, Analyt Instrument Div, Applicat & Res Ctr, MS Applicat Lab, Tokyo 1960021, Japan
[2] JEOL Ltd, Analyt Instrument Div, MS R&D Dept, Tokyo 1960021, Japan
[3] JEOL Ltd, Design Dept 1, Grp 2, Tokyo 1960021, Japan
关键词
D O I
10.1002/(SICI)1097-0231(20000615)14:11<947::AID-RCM970>3.0.CO;2-N
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new technique for accurate mass determination by using multiple sprayers nano-electrospray ionization mass spectrometry (nano-ESI-MS) on a magnetic sector instrument is described. Metal coated glass capillaries were used as nano-ESI sprayers. One of the sprayers was used for the reference compound solution, and others were used for the introduction of sample solutions. The spectra of the different compounds were obtained by shifting each sprayer's position relative to the sampling orifice. The accurate masses of several standard compounds were obtained with good accuracy, without problems arising from differences in ionization efficiency between the sample compounds and reference compound. Copyright (C) 2000 John Wiley & Sons, Ltd.
引用
收藏
页码:947 / 949
页数:3
相关论文
共 17 条
[1]   Development and validation of a high-performance liquid chromatography tandem mass spectrometry assay for atorvastatin, ortho-hydroxy atorvastatin, and para-hydroxy atorvastatin in human, dog, and rat plasma [J].
Bullen, WW ;
Miller, RA ;
Hayes, RN .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (01) :55-66
[2]  
Careri M, 1998, RAPID COMMUN MASS SP, V12, P225, DOI 10.1002/(SICI)1097-0231(19980314)12:5<225::AID-RCM147>3.0.CO
[3]  
2-K
[4]   ELECTROSPRAY IONIZATION MAGNETIC-SECTOR MASS-SPECTROMETRY - CALIBRATION, RESOLUTION, AND ACCURATE MASS MEASUREMENTS [J].
CODY, RB ;
TAMURA, J ;
MUSSELMAN, BD .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1561-1570
[5]   DETERMINATION OF NANOGRAM LEVELS OF PEPTIDE DRUG IN RABBIT AND HUMAN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COUPLED WITH ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY [J].
CROWTHER, J ;
ADUSUMALLI, V ;
MUKHERJEE, T ;
JORDAN, K ;
ABUAF, P ;
CORKUM, N ;
GOLDSTEIN, G ;
TOLAN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2356-2361
[6]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[7]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[8]  
Garzotti M, 1998, RAPID COMMUN MASS SP, V12, P61, DOI 10.1002/(SICI)1097-0231(19980131)12:2<61::AID-RCM117>3.0.CO
[9]  
2-A
[10]   EFFECT OF MULTIPLE SPRAYERS ON DYNAMIC-RANGE AND FLOW-RATE LIMITATIONS IN ELECTROSPRAY AND IONSPRAY MASS-SPECTROMETRY [J].
KOSTIAINEN, R ;
BRUINS, AP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (07) :549-558