Dosimetric evaluation of the staff working in a PET/CT department

被引:14
作者
Dalianis, K.
Malamitsi, J.
Gogou, L.
Pagou, M.
Efthimiadou, R.
Andreou, J.
Louizi, A.
Georgiou, E.
机构
[1] Harvard Med Int, Diagnost & Therapeut Ctr Athens Hygeia, Dept PET CT, Athens, Greece
[2] Univ Athens, Sch Med, Dept Med Phys, Athens, Greece
关键词
radiation protection; PET/CT; dosimetry;
D O I
10.1016/j.nima.2006.08.140
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The dosimetric literature data concerning the medical personnel working in positron emission tomography/computed tomography (PET/CT) departments are limited. Therefore, we measured the radiation dose of the staff working in the first PET/CT department in Greece at the Diagnostic and Therapeutic Center of Athens HYGEIA-Harvard Medical International. As, for the time being, only 2deoxy-2- [F-18]fluoro-d-glucose (FDG) PET studies are performed, radiation dose measurements concern those derived from dispensing of the radiopharmaceutical as well as from the patients undergoing FDG-PET imaging. Our aim is to develop more effective protective measures against radionuclide exposure. To estimate the effective dose from external exposure, all seven members of the staff (two nurses, two medical physicists, two technologists, one secretary) had TLD badges worn at the upper pocket of their overall, TLD rings on the right hand and digital dosimeters at their upper side pocket. In addition, isodose curves were measured with thermoluminescence detectors for distances of 20, 50, 70 and 100 cm away from patients who had been injected with F-18-FDG. Dose values of the PET/CT staff were measured with digital detectors, TLD badges and TLD rings over the first 8 months for a total of 160 working days of the department's operation, consisting of a workload of about 10-15 patients/week who received 250-420 MBq of F-18-FDG each. Whole body collective doses and hand doses for the staff were the following: Nurse #1 received 1.6 mSv as a whole body dose and 2,1 as a hand dose, Nurse #2 received 1.9 and 2.4 mSv respectively. For medical physicist #1 the dose values were 1.45 mSv whole body and 1.7 mSv hand dose, for medical physicist #2 1.67 mSv wholebody dose and 1.55 mSv hand dose and for technologists #1 & #2 the whole body doses were 0.7 and 0.64 mSv respectively. Lastly, the secretary received 0.1 mSv whole body dose. These preliminary data have shown that the dose levels of our PET/CT staff are within acceptable limits. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:548 / 550
页数:3
相关论文
共 9 条
[1]   Radiation dose rates from patients undergoing PET: implications for technologists and waiting areas [J].
Benatar, NA ;
Cronin, BF ;
O'Doherty, MJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (05) :583-589
[2]   Measurements of occupational exposure for a technologist performing 18F FDG PET scans [J].
Biran, T ;
Weininger, J ;
Malchi, S ;
Marciano, R ;
Chisin, R .
HEALTH PHYSICS, 2004, 87 (05) :539-544
[3]  
BRIAN T, 2004, HEALTH PHYS, V87, P539
[4]  
BUCHILLIER T, 2004, RADIAT PROT DOSIM, V110, P1173
[5]   Optimal dose of 18F-FDG required for whole-body PET using an LSO PET camera [J].
Everaert, H ;
Vanhove, C ;
Lahoutte, T ;
Muylle, K ;
Caveliers, V ;
Bossuyt, A ;
Franken, PR .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (12) :1615-1619
[6]   Distribution of equivalent doses to skin of the hands of nuclear medicine personnel [J].
Janowski, J ;
Olszewski, J ;
Kluska, K .
RADIATION PROTECTION DOSIMETRY, 2003, 106 (02) :177-180
[7]  
Lundberg Thea M, 2002, J Nucl Med Technol, V30, P25
[8]  
Roberts FO, 2005, J NUCL MED TECHNOL, V33, P44
[9]   Patient self-attenuation and technologist dose in positron emission tomography [J].
Zeff, BW ;
Yester, MV .
MEDICAL PHYSICS, 2005, 32 (04) :861-865