Responses to Continuous Glucose Monitoring in Subjects with Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections

被引:25
作者
Rodbard, David [1 ]
Jovanovic, Lois [2 ]
Garg, Satish K. [3 ]
机构
[1] Biomed Informat Consultants LLC, Potomac, MD 20854 USA
[2] Sansum Diabet Res Inst, Santa Barbara, CA USA
[3] Univ Colorado Denver, Barbara Davis Ctr Diabet, Aurora, CO USA
关键词
IMPROVED GLYCEMIC CONTROL; OXIDATIVE STRESS; VARIABILITY; QUALITY; FLUCTUATIONS; ACTIVATION; SENSOR; INDEX; BLOOD;
D O I
10.1089/dia.2009.0078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We compared changes in response to unmasking of continuous glucose monitoring (CGM) in subjects with type 1 diabetes who use multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII). Research Design and Methods: Use of real-time CGM (DexCom [San Diego, CA] SEVEN(R)) was studied in 38 subjects using CSII and 26 using MDI. CGM output was masked during Week 1 and unmasked during Weeks 2 and 3. We evaluated changes in 16 criteria for quality of glycemic control and eight criteria for glycemic variability. Results: All 24 criteria showed highly statistically significant improvement when considered simultaneously (P < 0.000001). For subjects using CSII, 18 of 24 criteria improved significantly (nominal P < 0.05); for subjects using MDI, 16 of 24 criteria improved significantly (P < 0.05). Twelve of the comparisons remained significant (P < 0.05) after applying the overconservative Bonferroni correction for multiple comparisons. The percentage of glucose values within the range 80-140mg/dL increased by 19% and 17% relative to their control values (Week 1) for subjects using MDI and CSII, respectively. Mean glucose, overall SD (SDT), SD between daily means (SDdm), mean amplitude of glycemic excursion (MAGE), and mean of daily differences (MODD) improved significantly. Responses to CGM display were not significantly different between the MDI and CSII subject groups for any of the 24 criteria considered individually or in groups of eight, 16, or 24. Conclusion: CGM has similar effectiveness in subjects with type 1 diabetes using either CSII or MDI.
引用
收藏
页码:757 / 765
页数:9
相关论文
共 27 条
[1]   Reduction in hemoglobin A1c with real-time continuous glucose monitoring: Results from a 12-week observational study [J].
Bailey, Timothy S. ;
Zisser, Howard C. ;
Garg, Satish K. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2007, 9 (03) :203-210
[2]   The Effect of Continuous Glucose Monitoring in Well-Controlled Type 1 Diabetes [J].
Beck, Roy W. .
DIABETES CARE, 2009, 32 (08) :1378-1383
[3]   Oscillating glucose is more deleterious to endothelial function and oxidative stress than mean glucose in normal and type 2 diabetic patients [J].
Ceriello, Antonio ;
Esposito, Katherine ;
Piconi, Ludovica ;
Ihnat, Michael A. ;
Thorpe, Jessica E. ;
Testa, Roberto ;
Boemi, Massimo ;
Giugliano, Dario .
DIABETES, 2008, 57 (05) :1349-1354
[4]   Statistical Tools to Analyze Continuous Glucose Monitor Data [J].
Clarke, William ;
Kovatchev, Boris .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 :S45-S54
[5]   Reducing glycaemic variability in type 1 diabetes self-management with a continuous glucose monitoring system based on wired enzyme technology [J].
Danne, T. ;
de Valk, H. W. ;
Kracht, T. ;
Walte, K. ;
Geldmacher, R. ;
Soelter, L. ;
von dem Berge, W. ;
Welsh, Z. K. ;
Bugler, J. R. ;
Lange, K. ;
Kordonouri, O. .
DIABETOLOGIA, 2009, 52 (08) :1496-1503
[6]   Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring [J].
Deis, Dorothee ;
Bolinder, Jan ;
Riveline, Jean-Pierre ;
Battelino, Tadej ;
Bosi, Emanuele ;
Tubiana-Rufi, Nadia ;
Kerr, David ;
Phillip, Moshe .
DIABETES CARE, 2006, 29 (12) :2730-2732
[7]   Relative inaccuracy of the A1cNow in children with type 1 diabetes [J].
Fox, Larry ;
Dontchev, Mariya ;
Ruedy, Katrina ;
Beck, Roy ;
Kollman, Craig ;
Messer, Laurel ;
Coffey, Julie ;
Wilson, Darrell ;
Doyle, Elizabeth ;
Tamborlane, William ;
Steffes, Michael .
DIABETES CARE, 2007, 30 (01) :135-137
[8]   Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor [J].
Garg, S ;
Zisser, H ;
Schwartz, S ;
Bailey, T ;
Kaplan, R ;
Ellis, S ;
Jovanovic, L .
DIABETES CARE, 2006, 29 (01) :44-50
[9]   Relationship of fasting and hourly glucose levels to HbA1c values blood [J].
Garg, Satish ;
Jovanovic, Lots .
DIABETES CARE, 2006, 29 (12) :2644-2649
[10]   Continuous home monitoring of glucose - Improved glycemic control with real-life use of continuous glucose sensors in adult subjects with type 1 diabetes [J].
Garg, Satish K. ;
Kelly, William C. ;
Voelmle, Mary K. ;
Ritchie, Peter J. ;
Gottlieb, Peter A. ;
McFann, Kim K. ;
Ellis, Samuel L. .
DIABETES CARE, 2007, 30 (12) :3023-3025