A randomized clinical 1-year trial comparing two types of non-submerged dental implants

被引:21
作者
Park, Jong-Chul [1 ]
Ha, Seung-Ryong [2 ]
Kim, Soung-Min [1 ]
Kim, Myung-Jin [1 ]
Lee, Jai-Bong [2 ]
Lee, Jong-Ho [1 ,3 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Seoul 110749, South Korea
[2] Seoul Natl Univ, Sch Dent, Dept Prosthodont, Seoul 110749, South Korea
[3] Seoul Natl Univ, Dent Hosp, Clin Dent Res Inst, Clin Trial Ctr, Seoul 110749, South Korea
关键词
dental implant; osstem SSII implant system; randomized clinical trial; Straumann (R) dental implant system; RESONANCE FREQUENCY-ANALYSIS; FINITE-ELEMENT-ANALYSIS; TITANIUM IMPLANTS; ITI(R) IMPLANTS; ORAL IMPLANT; FOLLOW-UP; IN-VIVO; SURFACE; STABILITY; BONE;
D O I
10.1111/j.1600-0501.2009.01828.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study compared the implant stability and clinical outcomes obtained with two types of non-submerged dental implants that have different thread designs and surface treatments. Materials and methods A randomized clinical trial with 1 year of follow-up was performed on 56 participants with 75 implants (control group, 36 implants in 28 subjects; experimental group, 39 implants in 28 subjects). The experimental group received the Osstem SSII Implant system; the control group received the Standard Straumann (R) Dental Implant System. The diameter and length of the fixture were uniform at 4.1 mm and 10 mm and all the implants restored the unilateral loss of one or two molars from the mandible. To compare implant stability, the peak insertion torque, implant stability quotient (ISQ), and periotest value (PTV) were evaluated during surgery, and at 4 and 10 weeks after surgery. To compare marginal bone loss, standard periapical radiographs were obtained during surgery, and at 10 weeks and 1 year after surgery. Results This study showed statistically significant differences between the two groups in peak insertion torque (P=0.009) and ISQ (P=0.003) but not in PTV (P=0.097) at surgery. In contrast, there was no statistically significant difference in the pattern of change of ISQ during the 10 weeks after surgery (P=0.339). For marginal bone loss, no significant difference was observed between the control and the experimental groups before functional loading (P=0.624), but after 1 year of follow-up, a borderline difference was observed (P=0.048). Conclusion The success rate after 1 year of follow-up was 100% for both implant system despite the presence of a significant difference in implant stability during surgery. There was a borderline difference in marginal bone loss after 1 year of follow-up. To cite this article:Park J-C, Ha S-R, Kim S-M, Kim M-J, Lee J-B, Lee J-H. A randomized clinical 1-year trial comparing two types of non-submerged dental implant.Clin. Oral Impl. Res. 21, 2010; 228-236.doi: 10.1111/j.1600-0501.2009.01828.x.
引用
收藏
页码:228 / 236
页数:9
相关论文
共 38 条
  • [21] Histomorphometric evaluation of immediately loaded SSII implants of different surface treatments in a dog model
    Jeon, Woo-Jin
    Kim, Su-Gwan
    Lim, Sung-Chul
    Ong, Joo L.
    Oh, Daniel Sunho
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 90A (02) : 396 - 400
  • [22] Oxidized titanium implants (Nobel Biocare® TiUnite™) compared with turned titanium implants (Nobel Biocare® mark III™) with respect to implant failure in a group of consecutive patients treated with early functional loading and two-stage protocol
    Jungner, M
    Lundqvist, P
    Lundgren, S
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (03) : 308 - 312
  • [23] Resonance frequency analysis and damping capacity assessment -: Part 2:: peri-implant bone loss follow-up.: An in vitro study with the Periotest™ and Osstell™ instruments
    Lachmann, S
    Laval, JY
    Jäger, B
    Axmann, D
    Gomez-Roman, G
    Groten, M
    Weber, H
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (01) : 80 - 84
  • [24] Lekholm U., 1985, TISSUE INTEGRATED PR
  • [25] Meredith N, 1998, INT J PROSTHODONT, V11, P269
  • [26] Meredith N, 1998, INT J PROSTHODONT, V11, P491
  • [27] O'Sullivan D, 2000, Clin Implant Dent Relat Res, V2, P85, DOI 10.1111/j.1708-8208.2000.tb00110.x
  • [28] O'Sullivan Dominic, 2004, Clin Implant Dent Relat Res, V6, P48, DOI 10.1111/j.1708-8208.2004.tb00027.x
  • [29] OLIVE J, 1990, International Journal of Oral and Maxillofacial Implants, V5, P390
  • [30] Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    Rabel, Annette
    Koehler, Steffen Gerhard
    Schmidt-Westhausen, Andrea Maria
    [J]. CLINICAL ORAL INVESTIGATIONS, 2007, 11 (03) : 257 - 265