Objectives This study compared the implant stability and clinical outcomes obtained with two types of non-submerged dental implants that have different thread designs and surface treatments. Materials and methods A randomized clinical trial with 1 year of follow-up was performed on 56 participants with 75 implants (control group, 36 implants in 28 subjects; experimental group, 39 implants in 28 subjects). The experimental group received the Osstem SSII Implant system; the control group received the Standard Straumann (R) Dental Implant System. The diameter and length of the fixture were uniform at 4.1 mm and 10 mm and all the implants restored the unilateral loss of one or two molars from the mandible. To compare implant stability, the peak insertion torque, implant stability quotient (ISQ), and periotest value (PTV) were evaluated during surgery, and at 4 and 10 weeks after surgery. To compare marginal bone loss, standard periapical radiographs were obtained during surgery, and at 10 weeks and 1 year after surgery. Results This study showed statistically significant differences between the two groups in peak insertion torque (P=0.009) and ISQ (P=0.003) but not in PTV (P=0.097) at surgery. In contrast, there was no statistically significant difference in the pattern of change of ISQ during the 10 weeks after surgery (P=0.339). For marginal bone loss, no significant difference was observed between the control and the experimental groups before functional loading (P=0.624), but after 1 year of follow-up, a borderline difference was observed (P=0.048). Conclusion The success rate after 1 year of follow-up was 100% for both implant system despite the presence of a significant difference in implant stability during surgery. There was a borderline difference in marginal bone loss after 1 year of follow-up. To cite this article:Park J-C, Ha S-R, Kim S-M, Kim M-J, Lee J-B, Lee J-H. A randomized clinical 1-year trial comparing two types of non-submerged dental implant.Clin. Oral Impl. Res. 21, 2010; 228-236.doi: 10.1111/j.1600-0501.2009.01828.x.
引用
收藏
页码:228 / 236
页数:9
相关论文
共 38 条
  • [1] Implant design and intraosseous stability of immediately placed implants: a human cadaver study
    Akkocaoglu, M
    Uysal, S
    Tekdemir, I
    Akca, K
    Cehreli, MC
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (02) : 202 - 209
  • [2] Al-Nawas B, 2006, INT J ORAL MAX IMPL, V21, P726
  • [3] Albrektsson T, 2004, INT J PROSTHODONT, V17, P544
  • [4] Non-submerged implants in the treatment of the edentulous lower jaw - A 2-year longitudinal study
    Astrand, P
    Almfeldt, I
    Brunell, G
    Hamp, SE
    Hellem, S
    Karlsson, U
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (04) : 337 - 344
  • [5] Radiographic assessment of changes in marginal bone around endosseous implants supporting mandibular overdentures
    Batenburg, RHK
    Meijer, HJA
    Geraets, WGM
    van der Stelt, PF
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (04) : 221 - 224
  • [6] Behneke A, 2000, INT J ORAL MAX IMPL, V15, P633
  • [7] Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
  • [8] BRANEMARK P I, 1969, Scandinavian Journal of Plastic and Reconstructive Surgery, V3, P81
  • [9] Tissue integration of non-submerged implants 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants
    Buser, D.
    Weber, H-P
    Lang, N. P.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1990, 1 (01) : 33 - 40
  • [10] Long-term evaluation of non-submerged ITI implants .1. 8-year life table analysis of a prospective multi-center study with 2359 implants
    Buser, D
    MericskeStern, R
    Bernard, JP
    Behneke, A
    Behneke, N
    Hirt, HP
    Belser, UC
    Lang, NP
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) : 161 - 172