Torrefied Wood Field Tests at a Coal-Fired Power Plant

被引:6
作者
Boylan, Doug M. [1 ]
Roberts, G. Keith [2 ]
Zemo, B. R. [3 ]
Wilson, Jeff L. [2 ]
机构
[1] Univ Alabama Birmingham, Dept Mech Engn, Birmingham, AL 35202 USA
[2] Southern Co, Birmingham, AL 35242 USA
[3] APC Plant Gadsden, Gadsden, AL 35903 USA
关键词
Biomass; cofiring; Scholz; torrefied wood;
D O I
10.1109/TIA.2015.2470639
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Torrefied wood (TW) may offer the opportunity to generate relatively large amounts of renewable energy in existing coal-fired units. To test this, several blends of pelletized TW were successfully cofired with coal at percentages up to 100% TW in a 49-MWcoal-fired unit at a power plant in the southeastern United States. NOx and sulfur emissions were significantly reduced with increased TW. Boiler efficiency was reduced slightly due to high TW fuel moisture at testing. Issues with dust suppression and fuel pile self-ignition were successfully addressed. This paper presents the details of the testing and results.
引用
收藏
页码:751 / 757
页数:7
相关论文
共 5 条
[1]  
Boylan D., 2011, TECHNICAL ASSESSMENT
[2]  
Kiel J., 2012, INT WORKSH BIOM TORR
[3]  
O'Connor D., 2010, 1017602 EPRI
[4]  
Rogers M., 2005, EVALUATION FLAMMABIL
[5]  
Stephan C. R., 2012, COAL DUST EXPLOSION