Online measurement and control of solids moisture in fluidised bed dryers

被引:83
作者
Wang, H. G. [1 ]
Senior, P. R. [2 ]
Mann, R. [2 ]
Yang, W. Q. [1 ]
机构
[1] Univ Manchester, Sch Elect & Elect Engn, Manchester M60 1QD, Lancs, England
[2] Univ Manchester, Sch Chem Engn & Analyt Sci, Manchester M60 1QD, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
Fluidised bed dryer; Electrical capacitance tomography; Moisture measurement; Process control; CAPACITANCE TOMOGRAPHY; TEMPERATURE; SENSOR;
D O I
10.1016/j.ces.2009.03.014
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Currently, two main methods are used to take online measurement of the solids moisture in fluidised bed dryers, namely microwave resonance and near infrared spectroscopy. In this paper, a new online approach to solids moisture measurement of batch fluidised bed dryers by electrical capacitance tomography (ECT) is presented for the first time. Based on online measurement of solids moisture, it is possible to implement feedback control and process optimisation of batch fluidised bed drying processes, aiming to increase the operation efficiency and to improve product quality. A twin-plane ECT sensor with eight electrodes in each plane is mounted in the bottom of a glass fluidisation chamber. From the adjacent electrode pairs, the water content of the solids is estimated based on the correlation between the moisture content and the permittivity value. To reduce measurement error, the effect of temperature on moisture measurement is compensated. The fluidisation velocity is estimated by a semi-empirical function based on the measured water content. The acquired information is sent to a controller to adjust the air flow rate of the fluidised bed dryer. To validate the moisture measurement by ECT, a mathematical model has been developed, based on the measured temperature and relative humidity of the outlet air. The Landweber iteration method is applied to reconstruct images. The averaged solids concentration along the radial direction at different fluidisation conditions is given and compared with results by the linear back-projection (LBP) method. Results from batch drying processes with online measurement and feedback control are given and compared with no feedback control. To compare the operation efficiency. the thermal efficiency is considered and the results show the possibility of online control and optimisation of the fluidised bed drying processes, based on online measurement of solids moisture by ECT. Some challenges and future work are discussed. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2893 / 2902
页数:10
相关论文
共 21 条
[11]   A study of bubbling and slugging fluidised beds using the two-fluid granular temperature model [J].
Pain, CC ;
Mansoorzadeh, S ;
de Oliveira, CRE .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2001, 27 (03) :527-551
[12]  
Perry R.H., 1985, PERRYS CHEM ENG HDB
[13]   Continuous on-line measurement of solid moisture content during fluidized bed drying using triboelectric probes [J].
Portoghese, Federica ;
Berruti, Franco ;
Briens, Cedric .
POWDER TECHNOLOGY, 2008, 181 (02) :169-177
[14]   On-line monitoring of moisture content in an instrumented fluidized bed granulator with a multi-channel NIR moisture sensor [J].
Rantanen, J ;
Lehtola, S ;
Ramet, P ;
Mannermaa, JP ;
Yliruusi, J .
POWDER TECHNOLOGY, 1998, 99 (02) :163-170
[15]   Control of the fluidised bed in the pellet softening process [J].
van Schagen, Kim ;
Rietveld, Luuk ;
Babuska, Robert ;
Baars, Eric .
CHEMICAL ENGINEERING SCIENCE, 2008, 63 (05) :1390-1400
[16]  
VOJTECH VC, 1966, FLUIDISED BED DRYING
[17]   Model-based control of temperature and energy requirements in a fluidised furnace reactor [J].
Voutetakis, Spyros S. ;
Seferlis, Panos ;
Papadopoulou, Simira ;
Kyriakos, Yorgos .
ENERGY, 2006, 31 (13) :2418-2427
[18]   Investigation of batch fluidized-bed drying by mathematical modeling, CFD simulation and ECT measurement [J].
Wang, H. G. ;
Yang, W. Q. ;
Senior, P. ;
Raghavan, R. S. ;
Duncan, S. R. .
AICHE JOURNAL, 2008, 54 (02) :427-444
[19]   Modelling of batch fluidised bed drying of pharmaceutical granules [J].
Wang, H. G. ;
Dyakowski, T. ;
Senior, P. ;
Raghavan, R. S. ;
Yang, W. Q. .
CHEMICAL ENGINEERING SCIENCE, 2007, 62 (05) :1524-1535
[20]   Adaptive calibration of a capacitance tomography system for imaging water droplet distribution [J].
Yang, WQ ;
Chondronasios, A ;
Nattrass, S ;
Nguyen, VT ;
Betting, M ;
Ismail, I ;
McCann, H .
FLOW MEASUREMENT AND INSTRUMENTATION, 2004, 15 (5-6) :249-258