Three-dimensional fracture visualisation of multidetector CT of the skull base in trauma patients: comparison of three reconstruction algorithms

被引:19
作者
Ringl, Helmut [1 ]
Schernthaner, Ruediger [1 ]
Philipp, Marcel O. [1 ]
Metz-Schimmerl, Sylvia [1 ]
Czerny, Christian [1 ]
Weber, Michael [1 ]
Gaebler, Christian [2 ]
Steiner-Ringl, Andrea [1 ]
Peloschek, Philipp [1 ]
Herold, Christian J. [1 ]
Schima, Wolfgang [1 ]
机构
[1] Med Univ Vienna, Dept Radiol, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Trauma Surg, A-1090 Vienna, Austria
关键词
Computed tomography; Trauma; Fracture; Skull base; 3D reconstruction; Maximum intensity projection (MIP); RENAL-ARTERY STENOSIS; COMPUTED-TOMOGRAPHY; SURFACE; RADIOLOGY; BONE;
D O I
10.1007/s00330-009-1435-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to retrospectively assess the detection rate of skull-base fractures for three different three-dimensional (3D) reconstruction methods of cranial CT examinations in trauma patients. A total of 130 cranial CT examinations of patients with previous head trauma were subjected to 3D reconstruction of the skull base, using solid (SVR) and transparent (TVR) volume-rendering technique and maximum intensity projection (MIP). Three radiologists independently evaluated all reconstructions as well as standard high-resolution multiplanar reformations (HR-MPRs). Mean fracture detection rates for all readers reading rotating reconstructions were 39, 36, 61 and 64% for SVR, TVR, MIP and HR-MPR respectively. Although not significantly different from HR-MPR with respect to sensitivity (P=0.9), MIP visualised 18% of fractures that were not reported in HR-MPR. Because of the relatively low detection rate using HR-MPRs alone, we recommend reading MIP reconstructions in addition to the obligatory HR-MPRs to improve fracture detection.
引用
收藏
页码:2416 / 2424
页数:9
相关论文
共 26 条
[1]   PATTERNS OF SKULL BASE FRACTURE - A 3-DIMENSIONAL COMPUTED TOMOGRAPHIC STUDY [J].
ALI, QM ;
DIETRICH, B ;
BECKER, H .
NEURORADIOLOGY, 1994, 36 (08) :622-624
[2]   Accuracy and time efficiency for the detection of thoracic cage fractures - Volume rendering compared with transverse computed tomography images [J].
Alkadhi, H ;
Wildermuth, S ;
Marincek, B ;
Boehm, T .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (03) :378-385
[3]   The contribution of high-resolution multiplanar reformats of the skull base to the detection of skull-base fractures [J].
Connor, SEJ ;
Flis, C .
CLINICAL RADIOLOGY, 2005, 60 (08) :878-885
[4]   Computed tomography pseudofractures of the mid face and skull base [J].
Connor, SEJ ;
Tan, G ;
Fernando, R ;
Chaudhury, N .
CLINICAL RADIOLOGY, 2005, 60 (12) :1268-1279
[5]   Role of 3D CT in the evaluation of the temporal bone [J].
Fatterpekar, Girish M. ;
Doshi, Amish H. ;
Dugar, Mohit ;
Delman, Bradley N. ;
Naidich, Thomas P. ;
Som, Peter M. .
RADIOGRAPHICS, 2006, 26 :S117-U124
[6]   3-DIMENSIONAL IMAGING [J].
FISHMAN, EK ;
MAGID, D ;
NEY, DR ;
CHANEY, EL ;
PIZER, SM ;
ROSENMAN, JG ;
LEVIN, DN ;
VANNIER, MW ;
KUHLMAN, JE ;
ROBERTSON, DD .
RADIOLOGY, 1991, 181 (02) :321-337
[7]   ADVANCED COMPUTER-APPLICATIONS IN RADIOLOGY - CLINICAL-APPLICATIONS [J].
FISHMAN, EK ;
NEY, DR .
RADIOGRAPHICS, 1993, 13 (02) :463-475
[8]   Is routine computed tomographic (CT) scanning necessary in suspected basal skull fractures? [J].
Goh, KYC ;
Ahuja, A ;
Walkden, SB ;
Poon, WS .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (5-6) :353-357
[9]  
GRODD W, 1987, RADIOLOGE, V27, P502
[10]   Renal artery stenosis: CT angiography - Comparison of real-time volume-rendering and maximum intensity projection algorithms [J].
Johnson, PT ;
Halpern, EJ ;
Kuszyk, BS ;
Heath, DG ;
Wechsler, RJ ;
Nazarian, LN ;
Gardiner, GA ;
Levin, DC ;
Fishman, EK .
RADIOLOGY, 1999, 211 (02) :337-343