Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function

被引:23
|
作者
Wintersperger, Bernd J. [1 ]
Sincleair, Spencer
Runge, Val M.
Dietrich, Olaf
Huber, Armin
Reiser, Maximilian F.
Schoenberg, Stefan O.
机构
[1] Univ Munich, Univ Hosp Grosshadern, Dept Clin Radiol, Munich, Germany
[2] Texas A&M Univ, Hlth Sci Ctr, Scott & White Clin & Hosp, Dept Radiol, Temple, TX USA
关键词
heart; volume; magnetic resonance (MR); cine study; volume measurement; parallel imaging;
D O I
10.1007/s00330-006-0259-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of our study was to evaluate the accuracy of a multislice cine magnetic resonance imaging (MRI) technique with parallel imaging in regard to global and regional left ventricular function. Forty-two individuals underwent cine MRI on a 1.5-tesla scanner. Cine MRI used a steady-state free precession technique and was performed as a single-slice technique (nonTSENSE cine) and an accelerated multislice technique (TSENSE cine) with five slices per breath-hold. End diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) were evaluated for all data sets and in regard to regional wall motion and regional wall motion analysis, and quantitative regional wall thickness and systolic thickening were also assessed. EDV, ESV, and EF based on TSENSE cine showed excellent correlation to the nonTSENSE cine approach ( all r(2)= 0.99, P< 0.001). While EDV evaluations showed a small underestimation for TSENSE cine, ESV and EF showed accurate results compared with nonTSENSE cine. Both readers showed good agreement (kappa= 0.72) in regional wall motion assessment comparing both techniques. Data acquisition for the multislice approach was significantly shorter (similar to 75%) that in single-slice cine. We conclude that accurate evaluation of regional wall motion and left ventricular EF is possible using accelerated multislice cine MR with high spatial and temporal resolution.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 50 条
  • [41] Dual-Source Computed Tomography: Effect on Regional and Global Left Ventricular Function Assessment Compared to Magnetic Resonance Imaging
    Lueders, F.
    Fischbach, R.
    Seifarth, H.
    Wessling, J.
    Heindel, W.
    Juergens, K. U.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (10): : 962 - 969
  • [42] Cine MRI for the evaluation of influences of regional left ventricular wall motion abnormalities on global cardiac function after myocardial infarction and revascularization therapy.
    Sandstede, J
    Lipke, C
    Beer, M
    Harre, K
    Pabst, T
    Kenn, W
    Neubauer, S
    Hahn, D
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (06): : 424 - 430
  • [43] Reliability of single breath hold three-dimensional cine kat-ARC for the assessment of biventricular dimensions and function
    Muscogiuri, Giuseppe
    Gatti, Marco
    Dell'Aversana, Serena
    Pica, Silvia
    Andreini, Daniele
    Guaricci, Andrea, I
    Guglielmo, Marco
    Baggiano, Andrea
    Mushtaq, Saima
    Conte, Edoardo
    Gripari, Paola
    Annoni, Andrea
    Formenti, Alberto
    Mancini, Maria Elisabetta
    Rabbat, Mark G.
    Pepi, Mauro
    Pontone, Gianluca
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 124
  • [44] A simplified method for the determination of left atrial size and function using cine magnetic resonance imaging
    Jarvinen, VM
    Kupari, MM
    Poutanen, VP
    Hekali, PE
    MAGNETIC RESONANCE IMAGING, 1996, 14 (03) : 215 - 226
  • [45] Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm
    Bernd J. Wintersperger
    Konstantin Nikolaou
    Olaf Dietrich
    Johannes Rieber
    Matthias Nittka
    Maximilian F. Reiser
    Stefan O. Schoenberg
    European Radiology, 2003, 13 : 1931 - 1936
  • [46] Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm
    Wintersperger, BJ
    Nikolaou, K
    Dietrich, O
    Rieber, J
    Nittka, M
    Reiser, MF
    Schoenberg, SO
    EUROPEAN RADIOLOGY, 2003, 13 (08) : 1931 - 1936
  • [47] Evaluation of left ventricular function in patients with acute ischaemic stroke using cine cardiovascular magnetic resonance imaging
    Hellwig, Simon
    Grittner, Ulrike
    Elgeti, Matthias
    Wyschkon, Sebastian
    Nagel, Sebastian N.
    Fiebach, Jochen B.
    Krause, Thomas
    Herm, Juliane
    Scheitz, Jan F.
    Endres, Matthias
    Nolte, Christian H.
    Haeusler, Karl Georg
    Elgeti, Thomas
    ESC HEART FAILURE, 2020, 7 (05): : 2572 - 2580
  • [48] Compressed SENSE accelerated 3D single-breath-hold late gadolinium enhancement cardiovascular magnetic resonance with isotropic resolution: clinical evaluation
    Gertz, Roman Johannes
    Wagner, Anton
    Sokolowski, Marcel
    Lennartz, Simon
    Gietzen, Carsten
    Grunz, Jan-Peter
    Goertz, Lukas
    Kaya, Kenan
    ten Freyhaus, Henrik
    Persigehl, Thorsten
    Bunck, Alexander Christian
    Doerner, Jonas
    Naehle, Claas Philip
    Maintz, David
    Weiss, Kilian
    Katemann, Christoph
    Pennig, Lenhard
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [49] Evaluation of echocardiographic derived parameters for right ventricular size and function using cardiac magnetic resonance imaging
    Rothstein, Eric S.
    Palac, Robert T.
    O'Rourke, Daniel J.
    Venkataraman, Pranav
    Gemignani, Anthony S.
    Friedman, Scott E.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2021, 38 (08): : 1336 - 1344
  • [50] Accelerated Cardiac T2 Mapping using Breath-hold Multiecho Fast Spin-Echo Pulse Sequence with k-t FOCUSS
    Feng, Li
    Otazo, Ricardo
    Jung, Hong
    Jensen, Jens H.
    Ye, Jong C.
    Sodickson, Daniel K.
    Kim, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1661 - 1669