A New Coated Wire Selective Electrode for Quetiapine in Biological and Pharmaceutical Analysis

被引:9
作者
Arida, Hassan [1 ,2 ]
Al Robaian, Majed [1 ]
Elbeshlawy, Mena [3 ]
Fataftah, Amjad [4 ]
Al-Sllami, Ghalib [5 ]
机构
[1] Taif Univ, Pharm Coll, At Taif 888, Saudi Arabia
[2] Atom Energy Author, Hot Labs Ctr, Cairo 13759, Egypt
[3] Ain Shams Univ, Coll Girls, Chem Dept, Cairo, Egypt
[4] Alfaisal Univ, Coll Sci & Gen Studies, Chem Dept, Riyadh 11533, Saudi Arabia
[5] Naif Arab Univ Secur Sci, Forens Sci Coll, Forens Chem Dept, Riyadh, Saudi Arabia
关键词
Quetiapine; PVC membrane; coated wire electrode; pharmaceutical analysis; biological applications; ANTIPSYCHOTIC-DRUG QUETIAPINE; TEMPERATURE IONIC LIQUIDS; FILM MICRO-SENSOR; HUMAN PLASMA; POTENTIOMETRIC DETERMINATION; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL SENSOR; MEMBRANE; MICROSENSOR; TABLETS;
D O I
10.20964/2017.05.76
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Fabrication of organic PVC membrane based coated wire electrode for sensitive, fast, precise and simple determination of quetiapine in pharmaceutical formulation and urine samples is demonstrated. The new electrode was constructing using quetiapine : tetraphenyl borate ion pair complex as electroactive material, PVC as supporting matrix, 2-nitrophenyl octyl ether as mediator of solvent and potassium tetrakis (4-chlorophenyl) borate as lipophilic additive. The electrode provides Nernstian response (57 +/- 0.2 mV/decade) over a wide concentration range of 1x10(-5) to 1x10(-2) mol L-1 of quetiapine with lower limit of detection (3.2x10(-6) mol L-1), fast response time (less than ten seconds) and relatively long life span (30 days). Stability with verification of the suitability of the electrode to be applied in the analysis of drug quality control in pharmaceutical and biological (urine) samples was assessed. The results obtained revealed a good agreement with those obtained from independent standard method (high performance liquid chromatography). In the pharmaceutical analysis application, the recovery of the quetiapine selective electrode ranging from 98.83 to 103.27%, the confidence of the two methods is 95% and the standard deviation is 2.49. While in the biological analysis of urine, the recovery of the electrode with respect to the standard method ranging from 96.45 to 97.48 %, the confidence is 95 % and the standard deviation is 1.48.
引用
收藏
页码:4120 / 4133
页数:14
相关论文
共 33 条
[11]  
Davis PC, 1999, J PHARMACEUT BIOMED, V20, P271
[12]   Polarographic Analysis of Quetiapine in Pharmaceuticals [J].
El-Enany, Nahed ;
El-Brashy, Amina ;
Belal, Fathalla ;
El-Bahay, Nihal .
PORTUGALIAE ELECTROCHIMICA ACTA, 2009, 27 (02) :113-125
[13]   Electrochemical Studies for the Determination of Quetiapine Fumarate and Olanzapine Antipsychotic Drugs [J].
El-Shal, Manal A. .
ADVANCED PHARMACEUTICAL BULLETIN, 2013, 3 (02) :339-344
[14]  
Faridbod F, 2012, ANAL BIOANAL ELECTRO, V4, P315
[15]  
Faridbod F, 2013, INT J ELECTROCHEM SC, V8, P10461
[16]   Early treatment of a quetiapine and sertraline overdose with Intralipid® [J].
Finn, S. D. H. ;
Uncles, D. R. ;
Willers, J. ;
Sable, N. .
ANAESTHESIA, 2009, 64 (02) :191-194
[17]  
Ganjali MR, 2008, INT J ELECTROCHEM SC, V3, P1169
[18]  
Ganjali MR, 2009, INT J ELECTROCHEM SC, V4, P435
[19]   A novel gadolinium ion-selective membrane electrode based on 2-(4-phenyl-1, 3-thiazol-2-yliminomethyl) phenol [J].
Gupta, Vinod Kumar ;
Singh, Ashok Kumar ;
Kumawat, Lokesh Kumar .
ELECTROCHIMICA ACTA, 2013, 95 :132-138
[20]   Carbon paste electrode modified with functionalized nanoporous silica gel as a new sensor for determination of silver ion [J].
Javanbakht, Mehran ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz ;
Badiei, Alireza ;
Hasheminasab, Abed ;
Abdouss, Majid .
ELECTROANALYSIS, 2007, 19 (12) :1307-1314