Past, present and future of blood pressure measuring instruments and their calibration

被引:27
作者
Kumar, Rahul [1 ,2 ]
Dubey, P. K. [1 ]
Zafer, Afaqul [1 ,2 ]
Kumar, Ashok [1 ,2 ]
Yadav, Sanjay [1 ,2 ]
机构
[1] CSIR, Natl Phys Lab, Div Physicomech Metrol, Pressure Vacuum & Ultrason Metrol, Dr KS Krishnan Marg, New Delhi 110012, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
关键词
Blood pressure; Oscillometric technique; Auscultatory technique; Non-invasive blood pressure; ANEROID SPHYGMOMANOMETERS; CARDIOVASCULAR-DISEASE; MEASURING DEVICES; CUFF PRESSURE; HEART-ATTACK; ARM POSITION; VALIDATION; HYPERTENSION; ACCURACY; PHOTOPLETHYSMOGRAPHY;
D O I
10.1016/j.measurement.2020.108845
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Blood pressure (BP) measurement is very important and crucial parameter for monitoring, controlling and treatment of human health conditions. Measurement of BP is performed using variety of instruments. Out of these, (i) mechanical or mercury manometers and (ii) oscillometric digital sphygmomanometers, are the most commonly used devices. Although, the international recommendations (OIML R16-2) for the automatic BP measuring instrument is available, there is no uniform international standard or method of calibration available. In this paper, a terse review of different types of BP measuring techniques and devices, commercially available is presented along with some related important historical developments. A concise and consolidated report of the several existing methods of BP device calibration being used at various National Metrology Institutes (NMIs) and other leading research groups is also included. This would open new lines for the future researchers to standardise a uniform and acceptable calibration method for these devices which is need of the hour.
引用
收藏
页数:13
相关论文
共 102 条
  • [1] Type and accuracy of sphygmomanometers in primary care: a cross-sectional observational study
    A'Court, Christine
    Stevens, Richard
    Sanders, Sarah
    Ward, Alison
    McManus, Richard
    Heneghan, Carl
    [J]. BRITISH JOURNAL OF GENERAL PRACTICE, 2011, 61 (590) : e598 - e603
  • [2] AK, 1979, INDIRECT MEASUREMENT
  • [3] An intelligent healthcare monitoring framework using wearable sensors and social networking data
    Ali, Farman
    El-Sappagh, Shaker
    Islam, S. M. Riazul
    Ali, Amjad
    Attique, Muhammad
    Imran, Muhammad
    Kwak, Kyung-Sup
    [J]. FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2021, 114 : 23 - 43
  • [4] Priority-based data transmission using selective decision modes in wearable sensor based healthcare applications
    Alsiddiky, Abdulmonem
    Awwad, Waleed
    Bakarman, Khalid
    Fouad, H.
    Hassanein, Azza S.
    Soliman, Ahmed M.
    [J]. COMPUTER COMMUNICATIONS, 2020, 160 : 43 - 51
  • [5] Automatic blood pressure measurement: the oscillometric waveform shape is a potential contributor to differences between oscillometric and auscultatory pressure measurements
    Amoore, John N.
    Lemesre, Yann
    Murray, Ian C.
    Mieke, Stephan
    King, Susan T.
    Smith, Fiona E.
    Murray, Alan
    [J]. JOURNAL OF HYPERTENSION, 2008, 26 (01) : 35 - 43
  • [6] Validation of oscillometric noninvasive blood pressure measurement devices using simulators
    Amoore, John N.
    Lemesre, Yann
    Murray, Ian C.
    Vacher, Emilie
    Mieke, Stephan
    King, Susan T.
    Smith, Fiona E.
    Murray, Alan
    [J]. BLOOD PRESSURE MONITORING, 2007, 12 (04) : 251 - 253
  • [7] [Anonymous], VERTICAL KYMOGRAPH
  • [8] [Anonymous], 33901988 IS
  • [9] [Anonymous], 2020, 8106052020 ISOTS
  • [10] [Anonymous], 76521988 IS