Efficacy of the optimal ablation index-targeted strategy for pulmonary vein isolation in patients with atrial fibrillation: the OPTIMUM study results

被引:24
|
作者
Lee, So-Ryoung [1 ]
Choi, Eue-Keun [1 ]
Lee, Eui-Jae [1 ]
Choe, Won-Seok [1 ]
Cha, Myung-Jin [1 ]
Oh, Seil [1 ]
机构
[1] Seoul Natl Univ Hosp, Dept Internal Med, Seoul, South Korea
关键词
Atrial fibrillation; Pulmonary vein isolation; Ablation index; RADIOFREQUENCY LESION SIZE; CATHETER CONTACT FORCE; RECONNECTION; TRIAL;
D O I
10.1007/s10840-019-00565-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeThe ablation index (AI) is a recently developed marker for ablation lesion quality that incorporates contact force (CF), time, and power in a weighted formula. There is a paucity of information on whether AI-guided pulmonary vein isolation (PVI) could improve the outcome in patients with atrial fibrillation (AF). We evaluated the optimal AI threshold for avoiding acute pulmonary vein reconnection (PVR), and to compare the efficacy of optimal AI-targeted PVI with that of conventional CF-guided PVI.MethodsSeventy patients with AF (paroxysmal, 67%) were enrolled. In a phase 1 study, the patients underwent conventional CF-guided PVI (CON group), and the optimal AI threshold for avoiding acute PVR was identified. In phase 2, the patients underwent AI-guided PVI (OAI group). We compared the acute PVR rate between the CON group and the OAI group to demonstrate the efficacy of AI-guided PVI.ResultsIn phase 1 (n=38), acute PVR was observed in 57 of 532 (10.7%) segments. AI values of >= 450 at the anterior/roof segments and of >= 350 at the posterior/inferior/carina segments were identified as the optimal AI thresholds for avoiding acute PVR. In the phase 2 study targeting those AI values, the OAI group (n=32) showed a significantly lower acute PVR rate than the CON group (4.2% vs. 10.7%, p<0.001). The OAI group showed a higher minimum AI and smaller variations in AI values than the CON group.ConclusionsOptimal AI-targeted PVI is feasible and could improve the acute outcome in patients with AF.
引用
收藏
页码:171 / 181
页数:11
相关论文
共 50 条
  • [1] Efficacy of the optimal ablation index–targeted strategy for pulmonary vein isolation in patients with atrial fibrillation: the OPTIMUM study results
    So-Ryoung Lee
    Eue-Keun Choi
    Eui-Jae Lee
    Won-Seok Choe
    Myung-Jin Cha
    Seil Oh
    Journal of Interventional Cardiac Electrophysiology, 2019, 55 : 171 - 181
  • [2] Efficacy of ablation index-guided pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Jiang, Ruhong
    Chen, Minglong
    Fan, Jie
    Yi, Fu
    Tang, Anli
    Liu, Xingpeng
    Zhu, Wenqing
    Liu, Shaowen
    Huang, Xiaobo
    Liu, Qiang
    Ju, Weizhu
    Zhang, Xi
    Li, Jie
    He, Jiangui
    Shi, Liang
    Zhou, Genqing
    Wang, Yuegang
    Fu, Guosheng
    Jiang, Chenyang
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (10): : 1186 - 1193
  • [3] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Kobayashi, Shuhei
    Fukaya, Hidehira
    Oikawa, Jun
    Saito, Daiki
    Sato, Tetsuro
    Matsuura, Gen
    Arakawa, Yuki
    Shirakawa, Yuki
    Nishinarita, Ryo
    Horiguchi, Ai
    Ishizue, Naruya
    Kishihara, Jun
    Niwano, Shinichi
    Ako, Junya
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 123 - 131
  • [4] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Shuhei Kobayashi
    Hidehira Fukaya
    Jun Oikawa
    Daiki Saito
    Tetsuro Sato
    Gen Matsuura
    Yuki Arakawa
    Yuki Shirakawa
    Ryo Nishinarita
    Ai Horiguchi
    Naruya Ishizue
    Jun Kishihara
    Shinichi Niwano
    Junya Ako
    Journal of Interventional Cardiac Electrophysiology, 2021, 62 : 123 - 131
  • [5] Efficacy of pulmonary vein isolation by cryoballon ablation in patients with paroxysmal atrial fibrillation
    Klein, Gunnar
    Oswald, Hanno
    Gardiwal, Ajmal
    Luesebrink, Ulrich
    Lissel, Christoph
    Yu, Hong
    Drexler, Helmut
    HEART RHYTHM, 2008, 5 (06) : 802 - 806
  • [6] Use of Ablation Index-Guided Ablation Results in High Rates of Durable Pulmonary Vein Isolation and Freedom From Arrhythmia in Persistent Atrial Fibrillation Patients The PRAISE Study Results
    Hussein, Ahmed
    Das, Moloy
    Riva, Stefania
    Morgan, Maureen
    Ronayne, Christina
    Sahni, Ankita
    Shaw, Matthew
    Todd, Derick
    Hall, Mark
    Modi, Simon
    Natale, Andrea
    Dello Russo, Antonio
    Snowdon, Richard
    Gupta, Dhiraj
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (09) : e006576
  • [7] Ablation index-guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study
    Chen, Shaojie
    Schmidt, Boris
    Bordignon, Stefano
    Urbanek, Lukas
    Tohoku, Shota
    Bologna, Fabrizio
    Angelkov, Lazar
    Garvanski, Iskren
    Tsianakas, Nikolaos
    Konstantinou, Athanasios
    Trolese, Luca
    Weise, Felix
    Perrotta, Laura
    Chun, K. R. Julian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (12) : 2724 - 2731
  • [8] The efficacy of inducibility and circumferential ablation with pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Chang, Shih-Lin
    Tai, Ching-Tai
    Lin, Yenn-Jiang
    Wongcharoen, Wanwarang
    Lo, Li-Wei
    Tuan, Ta-Chuan
    Udyavar, Ameya R.
    Chang, Sheng-Hsiung
    Tsao, Hsuan-Ming
    Hsieh, Ming-Hsiung
    Hu, Yu-Feng
    Chen, Yi-Jen
    Chen, Shih-Ann
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (06) : 607 - 611
  • [9] Role of Pulmonary Veins Isolation in Persistent Atrial Fibrillation Ablation: The Pulmonary Vein Isolation in Persistent Atrial Fibrillation (PIPA) Study
    Stabile, Giuseppe
    Bertaglia, Emanuele
    Turco, Pietro
    Zoppo, Franco
    Iuliano, Assunta
    Zerbo, Francesca
    La Rocca, Vincenzo
    De Simone, Antonio
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 : S116 - S119
  • [10] Efficacy of cryoballoon ablation in patients with paroxysmal atrial fibrillation without time to pulmonary vein isolation assessment
    Stabile, Giuseppe
    Tondo, Claudio
    Curnis, Antonio
    Lunati, Maurizio
    Manfrin, Massimiliano
    Molon, Giulio
    Sciarra, Luigi
    Mantica, Massimo
    Iacopino, Saverio
    Arena, Giuseppe
    Landolina, Maurizio
    Arestia, Alberto
    Verlato, Roberto
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 272 : 118 - 122