Simulation of Computed Tomography Dose based on Voxel Phantom

被引:0
作者
Liu, Chunyu [1 ]
Lv, Xiangbo [1 ]
Li, Zhaojun [1 ]
机构
[1] Naval Acad Armament, Postdoctoral Programme, Beijing 100161, Peoples R China
来源
SEVENTH INTERNATIONAL CONFERENCE ON ELECTRONICS AND INFORMATION ENGINEERING | 2017年 / 10322卷
关键词
Computed Tomography; Monte Carlo simulations; Voxel phantom; Computed Tomography Dose Index; X-RAY-SPECTRA; MONTE-CARLO SIMULATIONS; MULTIDETECTOR CT MDCT; ADULT; EXPOSURE; SCANNER; PATIENT; MODEL; INDEX;
D O I
10.1117/12.2266124
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.
引用
收藏
页数:10
相关论文
共 26 条
  • [1] [Anonymous], 2009, ANN ICR P
  • [2] [Anonymous], 2007, ANN ICRP
  • [3] [Anonymous], 2000, ICRP PUBL
  • [4] Monte Carlo simulation of x-ray spectra in diagnostic radiology and mammography using MCNP4C
    Ay, MR
    Shahriari, M
    Sarkar, S
    Adib, M
    Zaidi, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (21) : 4897 - 4917
  • [5] A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms
    DeMarco, JJ
    Cagnon, CH
    Cody, DD
    Stevens, DM
    McCollough, CH
    O'Daniel, J
    McNitt-Gray, MF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (17) : 3989 - 4004
  • [6] Radiation exposure to patients from image guidance procedures and techniques to reduce the imaging dose
    Ding, George X.
    Munro, Peter
    [J]. RADIOTHERAPY AND ONCOLOGY, 2013, 108 (01) : 91 - 98
  • [7] CONSTRUCTION OF HYBRID CHINESE REFERENCE ADULT PHANTOMS AND ESTIMATION OF DOSE CONVERSION COEFFICIENTS FOR MUONS
    Dong, Liang
    Li, Taosheng
    Liu, Chunyu
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 219 - 227
  • [8] A review of patient dose and optimisation methods in adult and paediatric CT scanning
    Dougeni, E.
    Faulkner, K.
    Panayiotakis, G.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : E665 - E683
  • [9] The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations
    Gu, J.
    Bednarz, B.
    Caracappa, P. F.
    Xu, X. G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) : 2699 - 2717
  • [10] Assessment of patient organ doses and effective doses using the VIP-Man adult male phantom for selected cone-beam CT imaging procedures during image guided radiation therapy
    Gu, Jianwei
    Bednarz, Bryan
    Xu, X. George
    Jiang, Steve B.
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 131 (04) : 431 - 443