Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise?

被引:11
作者
Reis, Victor M. [1 ,2 ]
Vianna, Jeferson M. [3 ]
Barbosa, Tiago M. [1 ,4 ,5 ]
Garrido, Nuno [1 ,2 ]
Vilaca Alves, Jose [1 ,2 ]
Carneiro, Andre L. [6 ]
Aidar, Felipe J. [7 ]
Novaes, Jefferson [3 ]
机构
[1] CIDESD, Res Ctr Sports Sci Hlth Sci & Human Dev, Vila Real, Portugal
[2] Univ Tras Os Montes & Alto Douro, Vila Real, Portugal
[3] Univ Fed Juiz de Fora, Juiz De Fora, MG, Brazil
[4] Nanyang Technol Univ, Singapore, Singapore
[5] Polytech Inst Braganca, Braganca, Portugal
[6] Univ Estadual Montes Claros, Montes Claros, MG, Brazil
[7] Univ Fed Sergipe, Aracaju, Brazil
关键词
OXYGEN-UPTAKE; VALIDITY; FITNESS; ARM;
D O I
10.1371/journal.pone.0221284
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of the present study was to assess the accuracy of heart rate to estimate energy cost during eight resistance exercises performed at low intensities: half squat, 45 inclined leg press, leg extension, horizontal bench press, 45 degrees inclined bench press, lat pull down, triceps extension and biceps curl. 56 males (27.5 +/- 4.9 years, 1.78 +/- 0.06 m height, 78.67 +/- 10.7 kg body mass and 11.4 +/- 4.1% estimated body fat) were randomly divided into four groups of 14 subjects each. Two exercises were randomly assigned to each group and subjects performed four bouts of 4-min constant-intensity at each assigned exercise: 12%, 16%, 20% and 24% 1-RM. Exercise and intensity order were random. Each subject performed no more than 2 bouts in the same testing session. A minimum recovery of 24h was kept between sessions. During testing VO2 was measured with Cosmed K4b2 and heart rate was measured with Polar V800 monitor. Energy cost was calculated from mean VO2 during the last 30-s of each bout by using the energy equivalent 1 ml O-2 = 5 calorie. Linear regressions with heart rate as predictor and energy cost as dependent variable were build using mean data from all subjects. Robustness of the regression lines was given by the scatter around the regression line (Sy.x) and Bland-Altman plots confirmed the agreement between measured and estimated energy costs. Significance level was set at p <= 0.05. The regressions between heart rate and energy cost in the eight exercises were significant (p<0.01) and robustness was: half squat (Sy.x = 0,48 kcal.min(-1)), 45 degrees inclined leg press (Sy.x = 0,54 kcal.min(-1)), leg extension (Sy.x = 0,59 kcal.min(-1)), horizontal bench press (Sy.x= 0,47 kcal.min(-1)), 45 inclined bench press (Sy.x = 0,54 kcal.min(-1)), lat pull down (Sy.x = 0,28 kcal.min(-1)), triceps extension (Sy.x = 0,08 kcal.min(-1)) and biceps curl (Sy.x = 0,13 kcal.min(-1)). We conclude that during low-intensity resistance exercises it is possible to estimate aerobic energy cost by wearable heart rate monitors with errors below 10% in healthy young trained males.
引用
收藏
页数:8
相关论文
共 17 条
[1]   Is the VO2 slow component in heavy arm-cranking exercise associated with recruitment of type II muscle fibers as assessed by an increase in surface EMG? [J].
Bernasconi, Sylvain ;
Tordi, Nicolas ;
Perrey, Stephane ;
Parratte, Bernard ;
Monnier, Guy .
APPLIED PHYSIOLOGY NUTRITION AND METABOLISM-PHYSIOLOGIE APPLIQUEE NUTRITION ET METABOLISME, 2006, 31 (04) :414-422
[2]   The relationship between heart rate and oxygen uptake during non-steady state exercise [J].
Bot, SDM ;
Hollander, AP .
ERGONOMICS, 2000, 43 (10) :1578-1592
[3]   Validity of Wearable Activity Monitors during Cycling and Resistance Exercise [J].
Boudreaux, Benjamin D. ;
Hebert, Edward P. ;
Hollander, Daniel B. ;
Williams, Brian M. ;
Cormier, Corinne L. ;
Naquin, Mildred R. ;
Gillan, Wynn W. ;
Gusew, Emily E. ;
Kraemer, Robert R. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (03) :624-633
[4]   MECHANICAL LOAD AND PHYSIOLOGICAL RESPONSES OF FOUR DIFFERENT RESISTANCE TRAINING METHODS IN BENCH PRESS EXERCISE [J].
Buitrago, Sebastian ;
Wirtz, Nicolas ;
Yue, Zengyuan ;
Kleinoeder, Heinz ;
Mester, Joachim .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2013, 27 (04) :1091-1100
[5]  
COLLINS MA, 1991, MED SCI SPORT EXER, V23, P636
[6]   Accuracy of polar S410 heart rate monitor to estimate energy cost of exercise [J].
Crouter, SE ;
Albright, C ;
Bassett, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (08) :1433-1439
[7]   Quantity and Quality of Exercise for Developing and Maintaining Cardiorespiratory, Musculoskeletal, and Neuromotor Fitness in Apparently Healthy Adults: Guidance for Prescribing Exercise [J].
Garber, Carol Ewing ;
Blissmer, Bryan ;
Deschenes, Michael R. ;
Franklin, Barry A. ;
Lamonte, Michael J. ;
Lee, I-Min ;
Nieman, David C. ;
Swain, David P. .
MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2011, 43 (07) :1334-1359
[8]   GENERALIZED EQUATIONS FOR PREDICTING BODY DENSITY OF MEN [J].
JACKSON, AS ;
POLLOCK, ML .
BRITISH JOURNAL OF NUTRITION, 1978, 40 (03) :497-504
[9]   Oxygen uptake kinetics during high-intensity arm and leg exercise [J].
Koppo, K ;
Bouckaert, J ;
Jones, AM .
RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2002, 133 (03) :241-250
[10]  
Kraemer WJ., 1995, PHYSL ASSESSMENT HUM, P115