Linear retention index approach applied to liquid chromatography coupled to triple quadrupole mass spectrometry to determine oxygen heterocyclic compounds at trace level in finished cosmetics

被引:16
作者
Arigo, Adriana [1 ]
Dugo, Paola [1 ,2 ,3 ,4 ]
Rigano, Francesca [1 ]
Mondello, Luigi [1 ,2 ,3 ,4 ]
机构
[1] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, Messina, Italy
[2] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, Chromaleont Srl, Messina, Italy
[3] Univ Campus Biomed Rome, Dept Med, Unit Food Sci & Nutr, Rome, Italy
[4] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, BeSep Srl, Messina, Italy
关键词
Furocoumarins; LC-MS/MS; Linear Retention Index; Quality control; Method validation; Weighting factors; LC-MS/MS; QUANTIFICATION; FUROCOUMARINS; UV; FURANOCOUMARIN; IDENTIFICATION; CHEMISTRY; NOBILETIN; COUMARIN; PRODUCTS;
D O I
10.1016/j.chroma.2021.462183
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the European Union, cosmetic products are regulated by the Cosmetics Regulation (EC) No. 1223/2009. The Analytical Working Group of the International Fragrance Association (IFRA) suggested that a new sensitive analytical method is needed to determine psoralens in finished cosmetic products. This research provides an HPLC-MS/MS method for the quality control of 20 furocoumarins, 8 coumarins and 7 polymethoxyflavones in cosmetics. Thanks to the high sensitivity of the tandem mass spectrometry detection in Multiple Reaction Monitoring mode, psoralens contained in trace have been quantified in different products. The Limits of Quantifications were in the range 0.3-74 mu g L-1. A reliable identification was achieved combining the Linear Retention Index (LRI) system with the MS and MS/MS libraries. In particular, the attribution was based on the spectra similarity filtered by the LRI parameter. The robustness and reproducibility of the LRI approach was demonstrated by the comparison of the HPLC-MS/MS results here reported with those obtained in our previous study, by using an HPLC-PDA system. This method could be taken into account for quality control of furocoumarins in cosmetics, and by the main associations, such as IFRA, for the purpose of issuing new opinions. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:14
相关论文
共 54 条
[1]  
Api A M, 2015, Food Chem Toxicol, V82 Suppl, pS1, DOI 10.1016/j.fct.2014.11.014
[2]   Oxygen heterocyclic compound screening in Citrus essential oils by linear retention index approach applied to liquid chromatography coupled to photodiode array detector [J].
Arigo, Adriana ;
Rigano, Francesca ;
Micalizzi, Giuseppe ;
Dugo, Paola ;
Mondello, Luigi .
FLAVOUR AND FRAGRANCE JOURNAL, 2019, 34 (05) :349-364
[3]   Comparability of RP-HPLC retention indices of drugs in three databases [J].
Bogusz, M ;
Hill, DW ;
Rehorek, A .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (08) :1291-1316
[4]  
Commission Europeenne, 2005, SCI COMM CONS PROD S, V9
[5]   Quantification of furocoumarins in hydroalcoholic fragrances by a liquid chromatography-high resolution/accurate mass method [J].
Corbi, Elise ;
Peres, Christophe ;
David, Nathalie .
FLAVOUR AND FRAGRANCE JOURNAL, 2014, 29 (03) :173-183
[6]   Method validation using weighted linear regression models for quantification of UV filters in water samples [J].
da Silva, Claudia Pereira ;
Emidio, Elissandro Soares ;
Rodrigues de Marchi, Mary Rosa .
TALANTA, 2015, 131 :221-227
[7]   Determination of new bioflavonoids in bergamot (Citrus bergamia) peel oil by liquid chromatography coupled to tandem ion trap-time-of-flight mass spectrometry [J].
Donato, Paola ;
Bonaccorsi, Ivana ;
Russo, Marina ;
Dugo, Paola .
FLAVOUR AND FRAGRANCE JOURNAL, 2014, 29 (02) :131-136
[8]   LC-MS for the identification of oxygen heterocyclic compounds in citrus essential oils [J].
Dugo, P ;
Mondello, L ;
Dugo, L ;
Stancanelli, R ;
Dugo, G .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 24 (01) :147-154
[9]  
Dugo P., 1997, Perfumer & Flavorist, V22, P25
[10]   Determination of Oxygen Heterocyclic Components in Citrus Products by HPLC with UV Detection [J].
Dugo, Paola ;
Piperno, Anna ;
Romeo, Roberto ;
Cambria, Maria ;
Russo, Marina ;
Carnovale, Caterina ;
Mondello, Luigi .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (15) :6543-6551