Physical human-robot interaction of an active pelvis orthosis: toward ergonomic assessment of wearable robots

被引:36
作者
d'Elia, Nicolo [1 ,2 ]
Vanetti, Federica [2 ]
Cempini, Marco [1 ]
Pasquini, Guido [2 ]
Parri, Andrea [1 ]
Rabuffetti, Marco [3 ]
Ferrarin, Maurizio [3 ]
Lova, Raffaele Molino [1 ]
Vitiello, Nicola [1 ,2 ]
机构
[1] Scuola Super Sant Anna, BioRobot Inst, Viale Rinaldo Piaggio 34, I-56025 Pisa, Italy
[2] Fdn Don Carlo Gnocchi IRCCS, Florence, Italy
[3] Fdn Don Carlo Gnocchi IRCCS, Milan, Italy
基金
欧盟地平线“2020”;
关键词
Wearable robotics; Active pelvis orthosis; Ergonomics; Passive degrees of freedom; Series-elastic actuation; EXOSKELETON; BACKPACK;
D O I
10.1186/s12984-017-0237-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: In human-centered robotics, exoskeletons are becoming relevant for addressing needs in the healthcare and industrial domains. Owing to their close interaction with the user, the safety and ergonomics of these systems are critical design features that require systematic evaluation methodologies. Proper transfer of mechanical power requires optimal tuning of the kinematic coupling between the robotic and anatomical joint rotation axes. We present the methods and results of an experimental evaluation of the physical interaction with an active pelvis orthosis (APO). This device was designed to effectively assist in hip flexion-extension during locomotion with a minimum impact on the physiological human kinematics, owing to a set of passive degrees of freedom for self-alignment of the human and robotic hip flexion-extension axes. Methods: Five healthy volunteers walked on a treadmill at different speeds without and with the APO under different levels of assistance. The user-APO physical interaction was evaluated in terms of: (i) the deviation of human lower-limb joint kinematics when wearing the APO with respect to the physiological behavior (i.e., without the APO); (ii) relative displacements between the APO orthotic shells and the corresponding body segments; and (iii) the discrepancy between the kinematics of the APO and the wearer's hip joints. Results: The results show: (i) negligible interference of the APO in human kinematics under all the experimented conditions; (ii) small (i.e., < 1 cm) relative displacements between the APO cuffs and the corresponding body segments (called stability); and (iii) significant increment in the human-robot kinematics discrepancy at the hip flexion-extension joint associated with speed and assistance level increase. Conclusions: APO mechanics and actuation have negligible interference in human locomotion. Human kinematics was not affected by the APO under all tested conditions. In addition, under all tested conditions, there was no relevant relative displacement between the orthotic cuffs and the corresponding anatomical segments. Hence, the physical human-robot coupling is reliable. These facts prove that the adopted mechanical design of passive degrees of freedom allows an effective human-robot kinematic coupling. We believe that this analysis may be useful for the definition of evaluation metrics for the ergonomics assessment of wearable robots.
引用
收藏
页数:14
相关论文
共 32 条
  • [1] Exoskeletons and robotic prosthetics: a review of recent developments
    Bogue, Robert
    [J]. INDUSTRIAL ROBOT-AN INTERNATIONAL JOURNAL, 2009, 36 (05) : 421 - 427
  • [2] 3-DIMENSIONAL ANALYSIS OF HUMAN WALKING - EXPERIMENTAL METHODS AND ASSOCIATED ARTIFACTS
    CAPPOZZO, A
    [J]. HUMAN MOVEMENT SCIENCE, 1991, 10 (05) : 589 - 602
  • [3] Analysis of relative displacement between the HX wearable robotic exoskeleton and the user's hand
    Cempini, Marco
    Marzegan, Alberto
    Rabuffetti, Marco
    Cortese, Mario
    Vitiello, Nicola
    Ferrarin, Maurizio
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
  • [4] Self-Alignment Mechanisms for Assistive Wearable Robots: A Kinetostatic Compatibility Method
    Cempini, Marco
    De Rossi, Stefano Marco Maria
    Lenzi, Tommaso
    Vitiello, Nicola
    Carrozza, Maria Chiara
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2013, 29 (01) : 236 - 250
  • [5] d'Elia N, 2015, GAIT POSTURE, DOI [10.1016/j.gaitpost.2015.07.042, DOI 10.1016/J.GAITPOST.2015.07.042]
  • [6] Lower extremity exoskeletons and active orthoses: Challenges and state-of-the-art
    Dollar, Aaron M.
    Herr, Hugh
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2008, 24 (01) : 144 - 158
  • [7] ESTIMATION OF DEFORMATION IN A WALKING ORTHOSIS FOR PARAPLEGIC PATIENTS
    FERRARIN, M
    STALLARD, J
    PALMIERI, R
    PEDOTTI, A
    [J]. CLINICAL BIOMECHANICS, 1993, 8 (05) : 255 - 261
  • [8] Ferrarin M., 1993, Clinical Rehabilitation, V7, P303, DOI [DOI 10.1177/026921559300700406, 10.1177/026921559300700406]
  • [9] A light-weight active orthosis for hip movement assistance
    Giovacchini, Francesco
    Vannetti, Federica
    Fantozzi, Matteo
    Cempini, Marco
    Cortese, Mario
    Parri, Andrea
    Yan, Tingfang
    Lefeber, Dirk
    Vitiello, Nicola
    [J]. ROBOTICS AND AUTONOMOUS SYSTEMS, 2015, 73 : 123 - 134
  • [10] Effects of varying backpack loads on peak forces in the lumbosacral spine during walking
    Goh, JH
    Thambyah, A
    Bose, K
    [J]. CLINICAL BIOMECHANICS, 1998, 13 : S26 - S31