Drying characteristics of wastewater sludge according to outside air inflow conditions

被引:0
作者
Oh, S. H. [1 ]
Park, K. H. [1 ]
Yu, B. H. [1 ]
Kim, S., I [1 ]
机构
[1] Korea Inst Energy Res, Energy Saving Technol Lab, Daejeon, South Korea
来源
IDS'2018: 21ST INTERNATIONAL DRYING SYMPOSIUM | 2018年
关键词
Drying; Sludge; Drying efficiency; Air inflow condition; SEWAGE-SLUDGE; MUNICIPAL;
D O I
10.4995/ids2018.2018.7790
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The purpose of this study is to analyze the changes of drying efficiency according to the inflow conditions of outside air into the drying equipment during the drying process in order to reduce the energy used in the drying process of sludge. We conducted the experiment using a vertical thin film dryer. Materials used for the experiment are sewage sludge. As a result of the study, higher drying efficiency was obtained in the case of outside air inflow than in the case of no outside air inflow. In addition, optimum condition of outside air inflow was derived.
引用
收藏
页码:1815 / 1821
页数:7
相关论文
共 4 条
[1]   Solar drying of wastewater sludge: A review [J].
Bennamoun, Lyes .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (01) :1061-1073
[2]   Impact of temperature on raw wastewater composition and activated sludge filterability in full-scale MBR systems for municipal sewage treatment [J].
Krzeminski, P. ;
Iglesias-Obelleiro, A. ;
Madebo, G. ;
Garrido, J. M. ;
van der Graaf, J. H. J. M. ;
van Lier, J. B. .
JOURNAL OF MEMBRANE SCIENCE, 2012, 423 :348-361
[3]   Physiochemical properties of digested sewage sludge with ultrasonic treatment [J].
Na, Seungmin ;
Kim, Young-Uk ;
Khim, Jeehyeong .
ULTRASONICS SONOCHEMISTRY, 2007, 14 (03) :281-285
[4]   Total concentrations and fractions of Cd, Cr, Pb, Cu, Ni and Zn in sewage sludge from municipal and industrial wastewater treatment plants [J].
Wang, C ;
Hu, X ;
Chen, ML ;
Wu, YH .
JOURNAL OF HAZARDOUS MATERIALS, 2005, 119 (1-3) :245-249