Improved synthetic T1-weighted images for cerebral tissue segmentation in neurological diseases

被引:13
作者
Gracien, Rene-Maxime [1 ,3 ,6 ]
van Wijnen, Alexandra [1 ,2 ,3 ]
Maiworm, Michelle [1 ,2 ,3 ,6 ]
Petrov, Franca [1 ,3 ]
Merkel, Nina [1 ,3 ,5 ,6 ]
Paule, Esther [1 ,3 ,6 ]
Steinmetz, Helmuth [1 ,6 ]
Knake, Susanne [4 ,6 ]
Rosenow, Felix [1 ,6 ]
Wagner, Marlies [2 ,3 ,6 ]
Deichmann, Ralf [3 ,6 ]
机构
[1] Goethe Univ, Dept Neurol, Frankfurt, Germany
[2] Goethe Univ, Dept Neuroradiol, Frankfurt, Germany
[3] Goethe Univ, Brain Imaging Ctr, Frankfurt, Germany
[4] Philipps Univ Marburg, Dept Neurol, Marburg, Germany
[5] Max Planck Gesell, Ernst Strungmann Inst Neurosci Cooperat, Frankfurt, Germany
[6] Ctr Personalized Translat Epilepsy Res CePTER Con, Frankfurt, Germany
关键词
Synthetic images; Quantitative MRI; T1; PD; Epilepsy; Focal cortical dysplasia; Multiple sclerosis (MS); SURFACE-BASED ANALYSIS; MULTIPLE-SCLEROSIS; SPOILED FLASH; WATER-CONTENT; BRAIN; T-1; FIELD; DENSITY; EPILEPSY; BIAS;
D O I
10.1016/j.mri.2019.05.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Structural cerebral MRI analysis in patients with neurological diseases usually requires T1-weighted datasets for tissue segmentation. For this purpose, synthetic T1-weighted images which are constructed from quantitative maps of the underlying tissue parameters such as the T1 relaxation time and the proton density (PD) may provide advantages over conventional datasets. However, in some cases synthetic images may suffer from specific artifacts, hampering accurate tissue segmentation. The goal was to improve a previously described method for the calculation of synthetic magnetization-prepared rapid gradient-echo (MP-RAGE) datasets from quantitative T1 and PD maps. Improvements comprise a B0-correction for the water-selective excitation pulses employed in T1-mapping and the use of T1-based pseudo-PD maps. Synthetic T1-weighted MP-RAGE datasets were calculated, using the standard and the improved algorithm, for 10 patients with focal epilepsy (caused by focal cortical dysplasia in 9), 10 patients with multiple sclerosis and 10 healthy control subjects and segmented with the Freesurfer toolbox. Visual inspection disclosed that segmentation of the standard synthetic datasets was inaccurate in 6 out of 10 patients with epilepsy, 7 out of 10 patients with multiple sclerosis and 7 out of 10 healthy control subjects, while the improved synthetic datasets resulted in adequate segmentation outcomes in the majority of cases. Only for one patient with multiple sclerosis and one with epilepsy, segmentation in basal temporal regions was not sufficient. Furthermore, data based on the standard algorithm showed strong signal non-uniformities in basal regions. This effect was not present in the improved synthetic datasets.
引用
收藏
页码:158 / 166
页数:9
相关论文
共 29 条
[1]   T1 mapping with the variable flip angle technique: A simple correction for insufficient spoiling of transverse magnetization [J].
Baudrexel, Simon ;
Noeth, Ulrike ;
Schuere, Jan-Ruediger ;
Deichmann, Ralf .
MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) :3082-3092
[2]   Detection of temporal lobe epilepsy using support vector machines in multi-parametric quantitative MR imaging [J].
Cantor-Rivera, Diego ;
Khan, Ali R. ;
Goubran, Maged ;
Mirsattari, Seyed M. ;
Peters, Terry M. .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 41 :14-28
[3]   Surgical outcome in patients with MRI-negative, PET-positive temporal lobe epilepsy [J].
Capraz, Irem Yildirim ;
Kurt, Gokhan ;
Akdemir, Ozgur ;
Hirfanoglu, Tugba ;
Oner, Yusuf ;
Sengezer, Tugba ;
Kapucu, Lutfiye Ozlem Atay ;
Serdaroglu, Ayse ;
Bilir, Erhan .
SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2015, 29 :63-68
[4]  
Cercignani M., 2018, Quantitative MRI of the Brain: Principles of Physical Measurement
[5]   MAGNETIC-RESONANCE IMAGING IN EPILEPSY - A CONTROLLED-STUDY [J].
CONLON, P ;
TRIMBLE, MR ;
ROGERS, D ;
CALLICOTT, C .
EPILEPSY RESEARCH, 1988, 2 (01) :37-43
[6]   Cortical surface-based analysis - I. Segmentation and surface reconstruction [J].
Dale, AM ;
Fischl, B ;
Sereno, MI .
NEUROIMAGE, 1999, 9 (02) :179-194
[7]  
Deichmann R, 2018, QUANTITATIVE MRI BRA
[8]   Use of magnetic resonance imaging for in vivo measurements of water content in human brain: method and normal values [J].
Fatouros, PP ;
Marmarou, A .
JOURNAL OF NEUROSURGERY, 1999, 90 (01) :109-115
[9]   INVIVO BRAIN WATER DETERMINATION BY T1 MEASUREMENTS - EFFECT OF TOTAL WATER-CONTENT, HYDRATION FRACTION, AND FIELD-STRENGTH [J].
FATOUROS, PP ;
MARMAROU, A ;
KRAFT, KA ;
INAO, S ;
SCHWARZ, FP .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :402-413
[10]   Cortical surface-based analysis - II: Inflation, flattening, and a surface-based coordinate system [J].
Fischl, B ;
Sereno, MI ;
Dale, AM .
NEUROIMAGE, 1999, 9 (02) :195-207