A Comparison of the Deflecting-Tip Bronchial Blocker With a Wire-Guided Blocker or Left-Sided Double-Lumen Tube

被引:34
|
作者
Dumans-Nizard, Virginie [1 ]
Liu, Ngai [1 ]
Laloe, Pierre-Antoine [1 ]
Fischler, Marc [1 ]
机构
[1] Hop Foch, Dept Anesthesiol, F-92151 Suresnes, France
关键词
one-lung ventilation; double-lumen endotracheal tube; bronchial blocker; TORQUE CONTROL BLOCKER; ONE-LUNG VENTILATION; ENDOTRACHEAL-TUBE; CARDIAC-SURGERY;
D O I
10.1053/j.jvca.2009.02.002
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To compare a new bronchial blocker, the Cohen blocker, with the Arndt blocker and a left double-lumen tube (DLT). Design: A prospective, randomized, controlled trial. Setting: University hospital. Participants: Forty-eight patients undergoing lung surgery. Intervention: Intubation with 1 of the 3 devices. Comparisons among groups included (1) time for initial positioning, (2) degree of lung collapse at pleura opening, and (3) number of intraoperative fiberoptic examinations. Measurements and Main Results: Positioning of the Cohen blocker (256 [166-341] seconds; median [interquartile range]) took no longer compared with the Arndt blocker (253 [184-305] seconds), and there was a trend toward difference between the 2 blockers and the DLT (137 [102-199] seconds) (p = 0.07). The time to place the Cohen blocker was longer in cases of left bronchus occlusion compared with a right one (340 [300-450] v 170 [124-259] seconds, p = 0.02); they were similar in the Arndt group. The degree of lung collapse was different among groups (p = 0.05), but the difference between any pair did not reach statistical significance. The number of patients who required at least 1 additional FOB examination was not statistically different (50% of patients in each blocker group v 19% in the DLT group). Conclusions: There was a trend toward a difference between times to place a bronchial blocker and the DLT. The Cohen blocker is more difficult to position in the left main bronchus than in the right one. (C) 2009 Elsevier Inc. All rights reserved
引用
收藏
页码:501 / 505
页数:5
相关论文
共 50 条
  • [41] Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery—a randomised controlled clinical trial
    Joachim Risse
    Karsten Szeder
    Ann-Kristin Schubert
    Thomas Wiesmann
    Hanns-Christian Dinges
    Carsten Feldmann
    Hinnerk Wulf
    Karl Matteo Meggiolaro
    BMC Anesthesiology, 22
  • [42] Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery-a randomised controlled clinical trial
    Risse, Joachim
    Szeder, Karsten
    Schubert, Ann-Kristin
    Wiesmann, Thomas
    Dinges, Hanns-Christian
    Feldmann, Carsten
    Wulf, Hinnerk
    Meggiolaro, Karl Matteo
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [43] Lung sonography can improve the specificity of determination of left-sided double-lumen tracheal tube position in both novices and experts: a randomised prospective study
    Chung, Jun-Young
    Go, YoonJu
    Jang, Yong Seok
    Lee, Bong-Jae
    Seo, Hyungseok
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (10)
  • [44] Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: incidence, risk factors and blind repositioning techniques
    Jeong-Hwa Seo
    Jun-Yeol Bae
    Hyun Joo Kim
    Deok Man Hong
    Yunseok Jeon
    Jae-Hyon Bahk
    BMC Anesthesiology, 15
  • [45] Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: incidence, risk factors and blind repositioning techniques
    Seo, Jeong-Hwa
    Bae, Jun-Yeol
    Kim, Hyun Joo
    Hong, Deok Man
    Jeon, Yunseok
    Bahk, Jae-Hyon
    BMC ANESTHESIOLOGY, 2015, 15
  • [46] Combined use of the ProSeal laryngeal mask airway and a bronchial blocker vs. a double-lumen endobronchial tube in thoracoscopic surgery: A randomized controlled trial
    Xue, Fu-Shan
    Gao, Xue
    Wan, Lei
    JOURNAL OF CLINICAL ANESTHESIA, 2024, 92
  • [47] Comparing the Effectiveness and Safety of MedAn with the Nishikawa Blade and UE Videolaryngoscopes for Left-Sided Double-Lumen Endobronchial Tube Intubation: A Randomized Controlled Trial
    Zhang, Yong
    Zhang, Wenwen
    Wang, Shuai
    Yin, Hailing
    Xu, Yajie
    Fang, Zhaojing
    Bao, Hongguang
    Zhang, Chen
    Wang, Xiaoliang
    Liu, Wentao
    MEDICAL SCIENCE MONITOR, 2023, 29
  • [48] Evaluation of time to intubation and rate of success for different healthcare professionals using a double-lumen left-sided endotracheal video tube: A prospective observational study
    Pedersen, Carsten M.
    Green, Jacob S.
    Bigler, Dennis R.
    Andersen, Niels E. O.
    Cromhout, Pernille F.
    JOURNAL OF PERIOPERATIVE PRACTICE, 2020, 30 (12) : 383 - 388
  • [49] Comparing the placement of a left-sided double-lumen tube via fiberoptic bronchoscopy guidance versus conventional intubation using a Macintosh laryngoscope, to reduce the incidence of malpositioning: study protocol for a randomized controlled pilot trial
    Ryu, Taeha
    Kim, Eugene
    Kim, Jong Hae
    Woo, Seong Jun
    Roh, Woon Seok
    Byun, Sung Hye
    TRIALS, 2019, 20 (1)
  • [50] VivaSight single-lumen tube guided bronchial blocker placement for one-lung ventilation in a patient with a tracheal tumor under video-assisted transthoracic surgery: a case report
    Qiu, Jin
    Feng, Miaomiao
    Zhang, Chuanhan
    Yao, Wenlong
    BMC ANESTHESIOLOGY, 2019, 19 (1)