A Comparison of the Deflecting-Tip Bronchial Blocker With a Wire-Guided Blocker or Left-Sided Double-Lumen Tube

被引:34
|
作者
Dumans-Nizard, Virginie [1 ]
Liu, Ngai [1 ]
Laloe, Pierre-Antoine [1 ]
Fischler, Marc [1 ]
机构
[1] Hop Foch, Dept Anesthesiol, F-92151 Suresnes, France
关键词
one-lung ventilation; double-lumen endotracheal tube; bronchial blocker; TORQUE CONTROL BLOCKER; ONE-LUNG VENTILATION; ENDOTRACHEAL-TUBE; CARDIAC-SURGERY;
D O I
10.1053/j.jvca.2009.02.002
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To compare a new bronchial blocker, the Cohen blocker, with the Arndt blocker and a left double-lumen tube (DLT). Design: A prospective, randomized, controlled trial. Setting: University hospital. Participants: Forty-eight patients undergoing lung surgery. Intervention: Intubation with 1 of the 3 devices. Comparisons among groups included (1) time for initial positioning, (2) degree of lung collapse at pleura opening, and (3) number of intraoperative fiberoptic examinations. Measurements and Main Results: Positioning of the Cohen blocker (256 [166-341] seconds; median [interquartile range]) took no longer compared with the Arndt blocker (253 [184-305] seconds), and there was a trend toward difference between the 2 blockers and the DLT (137 [102-199] seconds) (p = 0.07). The time to place the Cohen blocker was longer in cases of left bronchus occlusion compared with a right one (340 [300-450] v 170 [124-259] seconds, p = 0.02); they were similar in the Arndt group. The degree of lung collapse was different among groups (p = 0.05), but the difference between any pair did not reach statistical significance. The number of patients who required at least 1 additional FOB examination was not statistically different (50% of patients in each blocker group v 19% in the DLT group). Conclusions: There was a trend toward a difference between times to place a bronchial blocker and the DLT. The Cohen blocker is more difficult to position in the left main bronchus than in the right one. (C) 2009 Elsevier Inc. All rights reserved
引用
收藏
页码:501 / 505
页数:5
相关论文
共 50 条
  • [31] Airway Ventilation Pressures During Bronchoscopy, Bronchial Blocker, and Double-Lumen Endotracheal Tube Use: An In Vitro Study
    Kuo, Alexander S.
    Philip, James H.
    Edrich, Thomas
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (04) : 873 - 879
  • [32] Comparison of displacement of polyvinyl chloride and silicone left-sided double-lumen tubes during lateral positioning
    Kwon, Nyeong Keon
    Jung, Sung Mee
    Park, Sang-Jin
    Han, Yonghee
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2019, 72 (01) : 32 - 38
  • [33] Expert opinion on the use of fiberoptic bronchospe to check the insertion depth of the left-sided double-lumen tube
    Eldawlatly, Abdelazeem A.
    Basheer, Musaab K.
    AlHamdi, Malik A.
    El-Tahan, Mohamed R.
    SAUDI JOURNAL OF ANAESTHESIA, 2024, 18 (02) : 272 - 275
  • [34] Selective lobar blockade with a Coopdech blocker combined with a double-lumen endotracheal tube for lung metastases resection by laser
    Cruz, Patricia
    David Orozco, Hugo
    Garutti Martinez, Ignacio
    Hernandez Fernandez, Gloria
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2018, 68 (02): : 200 - 204
  • [35] Combined use of the ProSeal laryngeal mask airway and a bronchial blocker vs. a double-lumen endobronchial tube in thoracoscopic surgery: A randomized controlled trial
    Nakanishi, Toshiyuki
    Sento, Yoshiki
    Kamimura, Yuji
    Nakamura, Ryuji
    Hashimoto, Hiroya
    Okuda, Katsuhiro
    Nakanishi, Ryoichi
    Sobue, Kazuya
    JOURNAL OF CLINICAL ANESTHESIA, 2023, 88
  • [36] A randomized trial to assess the effect of cricoid displacing maneuver on the success rate of blind placement of double-lumen tube and Univent bronchial blocker
    Xu, Zhao
    Yu, Hong
    Luo, Yuting
    Ye, Yuancai
    Zhou, Cheng
    Liang, Peng
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (02) : 1976 - 1984
  • [37] Utilization of an Endobronchial Blocker Through a Double-Lumen Tube as Rescue for Inadequate One-Lung Ventilation
    Tang, Jonathan E.
    Roessner, Colton T.
    Stocum, Robert D.
    Stein, Erica J.
    Essandoh, Michael K.
    D'Souza, Desmond M.
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 28 (01) : 50 - 53
  • [38] Selective Lobar Blockade With a Bronchial Blocker in Combination With a Double Lumen Tube to Manage Refractory Hypoxemia: A Case Report
    Muelleck, Jason R.
    Maracaja, Luiz
    Templeton, Thomas W.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (07)
  • [39] RETRACTED: Comparison of Arndt-endobronchial blocker plus laryngeal mask airway with left-sided double-lumen endobronchial tube in one-lung ventilation in thoracic surgery in the morbidly obese (Retracted article. See vol. 51, art. e6825, 2018)
    Zhang, Z. J.
    Zheng, M. L.
    Nie, Y.
    Niu, Z. Q.
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2018, 51 (02)
  • [40] Randomized clinical trial comparing double-lumen tube and EZ-Blocker® for single-lung ventilation
    Ruetzler, K.
    Grubhofer, G.
    Schmid, W.
    Papp, D.
    Nabecker, S.
    Hutschala, D.
    Lang, G.
    Hager, H.
    BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (06) : 896 - 902