Intraoperative ureter identification with a novel fluorescent catheter

被引:15
作者
Barberio, Manuel [1 ,2 ,3 ]
Al-Taher, Mahdi [2 ,4 ]
Felli, Eric [1 ]
Ashoka, Anila Hoskere [5 ]
Marescaux, Jacques [2 ]
Klymchenko, Andrey [5 ]
Diana, Michele [2 ,6 ]
机构
[1] IHU Strasbourg, Inst Image Guided Surg, 1 Pl Hop, F-67091 Strasbourg, France
[2] IRCAD, Res Inst Digest Canc, Strasbourg, France
[3] Osped Cardinale G Pan, Tricase, LE, Italy
[4] Maastricht Univ, Med Ctr, Maastricht, Netherlands
[5] Univ Strasbourg, Lab Bioimagerie & Pathol, CNRS, UMR 7021, Strasbourg, France
[6] iCube Lab, Photon Hlth, Strasbourg, France
关键词
D O I
10.1038/s41598-021-84121-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Iatrogenic ureteral injuries (IUI) occur in 0.5-1.3% of cases during abdominal surgery. If not recognized intraoperatively, IUI increase morbidity/mortality. A universally accepted method to prevent IUI is lacking. Near-infrared fluorescent imaging (NIRF), penetrating deeper than normal light within the tissue, might be useful, therefore ureter visualization combining NIRF with special dyes (i.e. IRDye 800BK) is promising. Aim of this work is to evaluate the detection of ureters using stents coated with a novel biocompatible fluorescent material (NICE: near-infrared coating of equipment), during laparoscopy. female pigs underwent placement of NICE-coated stents (NS). NIRF was performed, and fluorescence intensity (FI) was computed. Successively, 0.15 mg/kg of IRDye 800BK was administered intravenously, and FI was computed at different timepoints. Ureter visualization using NS only was further assessed in a human cadaver. Both methods allowed in vivo ureter visualization, with equal FI. However, NS were constantly visible whereas IRDye 800BK allowed visualization exclusively during the ureteral peristaltic phases. In the human cadaver, NS provided excellent ureter visualization in its natural anatomical position. NS provided continuous ureteral visualization with similar FI as the IRDye 800BK, which exclusively allowed intermittent visualization, dependent on ureteral peristalsis. NS might prove useful to visualize ureters intraoperatively, potentially preventing IUI.
引用
收藏
页数:8
相关论文
共 33 条
[21]   Use of Indocyanine Green During Robot-assisted Ureteral Reconstructions [J].
Lee, Ziho ;
Moore, Blake ;
Giusto, Laura ;
Eun, Daniel D. .
EUROPEAN UROLOGY, 2015, 67 (02) :291-298
[22]   The role of tissue fluorescence in in vivo optical bioimaging [J].
Lifante, Jose ;
Shen, Yingli ;
Ximendes, Erving ;
Martin Rodriguez, Emma ;
Ortgies, Dirk H. .
JOURNAL OF APPLIED PHYSICS, 2020, 128 (17)
[23]   Incidence of Iatrogenic Ureteral Injury During Open and Laparoscopic Colorectal Surgery: A Single Center Experience and Review of the Literature [J].
Marcelissen, Tom A. T. ;
Den Hollander, Philip P. ;
Tuytten, Tom R. A. H. ;
Sosef, Meindert N. .
SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2016, 26 (06) :513-515
[24]   Intraoperative ureteric injuries and litigation in the NHS [J].
Nachiappan, S. ;
Currie, A. ;
Askari, A. ;
Faiz, O. .
JOURNAL OF CLINICAL UROLOGY, 2015, 8 (01) :9-13
[25]   A review of laparoscopic ureteral injury in pelvic surgery [J].
Ostrzenski, A ;
Radolinski, B ;
Ostrzenska, KM .
OBSTETRICAL & GYNECOLOGICAL SURVEY, 2003, 58 (12) :794-799
[26]   Application of a New Dye for Near-Infrared Fluorescence Laparoscopy of the Ureters: Demonstration in a Pig Model [J].
Schols, Rutger M. ;
Lodewick, Toine M. ;
Bouvy, Nicole D. ;
van Dam, Gooitzen M. ;
Dejong, Cornelis H. C. ;
Stassen, Laurents P. S. .
DISEASES OF THE COLON & RECTUM, 2014, 57 (03) :407-411
[27]   Indocyanine green for intraoperative localization of ureter [J].
Siddighi, Sam ;
Yune, Junchan Joshua ;
Hardesty, Jeffrey .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2014, 211 (04) :436.e1-436.e2
[28]   Currently available and experimental dyes for intraoperative near-infrared fluorescence imaging of the ureters: a systematic review [J].
Slooter, M. D. ;
Janssen, A. ;
Bemelman, W. A. ;
Tanis, P. J. ;
Hompes, R. .
TECHNIQUES IN COLOPROCTOLOGY, 2019, 23 (04) :305-313
[29]  
Summerton DJ, 2014, EUR UROL, V2, P227
[30]   Real-time intraoperative ureteral guidance using invisible near-infrared fluorescence [J].
Tanaka, Eiichi ;
Ohnishi, Shunsuke ;
Laurence, Rita G. ;
Choi, Hak Soo ;
Humblet, Valerie ;
Frangioni, John V. .
JOURNAL OF UROLOGY, 2007, 178 (05) :2197-2202