Microrough titanium surface affects biologic response in MG63 osteoblast-like cells

被引:115
作者
Kim, Myung-Joo
Kim, Chang-Whe
Lim, Young-Jun
Heo, Seong-Joo
机构
[1] Seoul Natl Univ, Fac Dent, Dept Prosthodont, Grad Sch, Seoul 110768, South Korea
[2] Seoul Natl Univ, Dent Res Inst, Seoul 110768, South Korea
关键词
surface analysis; microrough titanium surface; cell number; alkaline phosphatase; Runx2 gene expression; type I collagen;
D O I
10.1002/jbm.a.31040
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study vas to define the surface properties of prepared titanium (Ti) disks, which served as a model system, and to contrast the biologic response of MG63 cells exposed to Ti disks with different levels of surface roughness. The surface properties interact with each other, resulting in a change of other surface qualities in addition to roughness due to the surface roughening procedure. The machined Ti disks were roughened by sandblasting and electric glow discharging. The surface properties of the Ti specimens were inspected through a comprehensive surface analysis. MG63 cell behaviors were compared along with cell number, alkaline phosphatase (ALP) activity, Runx2 gene expression, and type I collagen production. Statistics were evaluated, using analysis of variance (ANOVA). The sandblasted Ti disks demonstrated well-controlled surface roughness features and meaningful average roughness ranges, including the surface roughness of the "modem' microrough implant, used clinically. With increasing Ti surface roughness, the cell number decreased, while the ALP activity, type I collagen production, and Runx2 gene expression increased significantly. The rougher the Ti surface was, the sooner the Runx2 gene was expressed. Based on these results, we suggest that the microrough Ti surfaces of the 1-3 mu m range may contribute effectively to osteogenic differentiation and proliferation in MG63 cells. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:1023 / 1032
页数:10
相关论文
共 43 条
[31]  
2-6
[32]   Understanding and controlling the bone-implant interface [J].
Puleo, DA ;
Nanci, A .
BIOMATERIALS, 1999, 20 (23-24) :2311-2321
[33]   SCANNING ELECTRON-MICROSCOPE STUDY OF CELL ADHESION AND SPREADING INVITRO [J].
RAJARAMAN, R ;
ROUNDS, DE ;
YEN, SPS ;
REMBAUM, A .
EXPERIMENTAL CELL RESEARCH, 1974, 88 (02) :327-339
[34]   Roughness induced dynamic changes of wettability of acid etched titanium implant modifications [J].
Rupp, F ;
Scheideler, L ;
Rehbein, D ;
Axmann, D ;
Gels-Gerstorfer, J .
BIOMATERIALS, 2004, 25 (7-8) :1429-1438
[35]   Differentiation of preosteoblasts is affected by implant surface microtopographies [J].
Schneider, GB ;
Zaharias, R ;
Seabold, D ;
Keller, J ;
Stanford, C .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 69A (03) :462-468
[36]   Implant surface roughness affects osteoblast gene expression [J].
Schneider, GB ;
Perinpanayagam, H ;
Clegg, M ;
Zaharias, R ;
Seabold, D ;
Keller, J ;
Stanford, C .
JOURNAL OF DENTAL RESEARCH, 2003, 82 (05) :372-376
[37]  
Schwartz Z, 1999, Adv Dent Res, V13, P38
[38]   Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: the oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition [J].
Sul, YT ;
Johansson, CB ;
Petronis, S ;
Krozer, A ;
Jeong, Y ;
Wennerberg, A ;
Albrektsson, T .
BIOMATERIALS, 2002, 23 (02) :491-501
[39]   Differential regulation of Cbfa1/Runx2 and osteocalcin gene expression by vitamin-D3, dexamethasone, and local growth factors in primary human osteoblasts [J].
Viereck, V ;
Siggelkow, H ;
Tauber, S ;
Raddatz, D ;
Schutze, N ;
Hüfner, M .
JOURNAL OF CELLULAR BIOCHEMISTRY, 2002, 86 (02) :348-356
[40]   MICROPLATE READER-BASED QUANTITATION OF COLLAGENS [J].
WALSH, BJ ;
THORNTON, SC ;
PENNY, R ;
BREIT, SN .
ANALYTICAL BIOCHEMISTRY, 1992, 203 (02) :187-190